CONTENTS Split Air Conditioner General Information ......... 1 Split Air Conditioner Model Nomenclature ............... 1 Application and Location .................................... 4 General .................................................................... 4Shipping Damage .......................
Page 3 - SPLIT AIR CONDITIONER MODEL NOMENCLATURE; HAC 36 1 – A DXXX
Manual 2100-346Page 1 SPLIT AIR CONDITIONER MODEL NOMENCLATURE TABLE 1 UNIT DIMENSIONS . o N l e d o M " W " h t d i W " D " h t p e D " H " t h g i e H A B C E F 1 8 1 C A H 1 4 2 C A H 0 0 . 0 4 0 0 . 5 1 0 0 . 6 2 5 2 1 . 5 8 8 1 . 0 2 0 0 . 4 5 2 1 . 7 8 8 1 . 4 2 1 0 3 C...
Page 6 - APPLICATION and LOCATION
Manual 2100-346Page 4 APPLICATION and LOCATION GENERAL These instructions explain the recommended method toinstall the air cooled remote type condensing unit, theinterconnecting refrigerant tubing and the electrical wiringconnections to the unit. The condensing units are to be used in conjunction wi...
Page 7 - CAUTION
Manual 2100-346Page 5 SWEAT STYLE TUBING CONNECTIONS: SWEATINDOOR UNIT and SWEAT OUTDOOR UNIT Use only refrigeration grade (dehydrated and sealed) coppertubing. Care must be taken to insure that the tubing is keptclean and dry before and during installation. Do not removethe plugs from the tubing en...
Page 11 - WIRING INSTRUCTIONS; GENERAL; WALL THERMOSTATS
Manual 2100-346Page 9 WIRING INSTRUCTIONS GENERAL All wiring must be installed in accordance with the NationalElectrical Code and local codes. In Canada, all wiring mustbe installed in accordance with the Canadian ElectricalCode and in accordance with the regulations of theauthorities having jurisdi...
Page 15 - INSTALLATION INSTRUCTIONS – CMA-10A
Manual 2100-346Page 13 INSTALLATION INSTRUCTIONS – CMA-10A Disconnect all power to unit. Remove control panel cover. 1. Screw compressor control module and terminal block into control panel as shown in Figure 5. 2. Disconnect yellow low voltage wire form compressor contactor and reconnect to termina...
Page 16 - INSTALLATION INSTRUCTIONS – CMA-13A
Manual 2100-346Page 14 INSTALLATION INSTRUCTIONS – CMA-13A Disconnect all power to unit. Remove control panel cover. 1. Screw compressor control module and terminal block into control panel as shown in Figure 5. 2. Disconnect yellow low voltage wire from compressor contactor and reconnect to termina...
Page 17 - PRESSURE SERVICE PORTS; CHARGING INSTRUCTIONS
Manual 2100-346Page 15 PRESSURE SERVICE PORTS High and low pressure service ports are installed on all unitsso that the system operating pressures can be observed.Pressure tables can be found later in the manual covering allmodels. It is imperative to match the correct pressure tableto the unit by m...
Page 19 - SERVICE; SERVICE HINTS; FAN BLADE SETTING DIMENSIONS
Manual 2100-346Page 17 SERVICE SERVICE HINTS 1. Caution homeowner to maintain clean air filters at all times. Also, not to needlessly close off supply andreturn air registers. This reduces air flow through thesystem, which shortens equipment service life, as wellas, increasing operating costs. 2. Ch...