Page 3 - Three-hole thermostatic tub filler -- requires rough 04124181
3 Three-hole thermostatic tub filler -- requires rough 04124181 04129XX0 04128XX0 04127XX0 04126XX0
Page 4 - Technical Information; Recommended water pressure; Installation Considerations; temperature limit stop may be reset to comply with these codes.
4 Technical Information Recommended water pressure 45 - 72 psi Recommended hot water temp. 120 � - 140 � F* Max. hot water temp 165 � F* Max. flow rate 8 gpm Max. flow rate – handshower 2.5 gpm Safety stop 100° F *Please know and follow all applicable local plumbing codes when setting the temperatur...
Page 5 - Install the valve trim; mm Allen wrench. The screw must; Over tightening the screw may; Install the spout; slot
5 Install the valve trim Push the escutcheon over the valve.Install the handle. Tighten the screw with a 3 mm Allen wrench. The screw must engage the slot on the cartridge.Justify the handle.Set the high temperature limit stop. Push the spout sealing ring firmly into the spout adapter (1).Push the e...