Page 2 - Owner’s Manual; Table of Contents
AtlasSound.com – 2 – Specifications are subject to change without notice. Owner’s Manual ECM-RACEWY ECM-20, ECM-20M, & ECM-30 1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A. Telephone: 800.876.3333 • Fax: 800.765.3435 Table of Contents Important Safety Instructions ...............................
Page 3 - Important Safety Instructions
– 3 – AtlasSound.com Specifications are subject to change without notice. Owner’s Manual ECM-RACEWY ECM-20, ECM-20M, & ECM-30 1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A. Telephone: 800.876.3333 • Fax: 800.765.3435 Important Safety Instructions 1. Read these instructions. 2. Keep these inst...
Page 4 - When The Device Is In Use; When Installing The Product; When The Product Is In Use; CAUTION
AtlasSound.com – 4 – Specifications are subject to change without notice. Owner’s Manual ECM-RACEWY ECM-20, ECM-20M, & ECM-30 1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A. Telephone: 800.876.3333 • Fax: 800.765.3435 When The Device Is In Use • To prevent electric shock, do not remove the pro...
Page 5 - Introduction
– 5 – AtlasSound.com Specifications are subject to change without notice. Owner’s Manual ECM-RACEWY ECM-20, ECM-20M, & ECM-30 1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A. Telephone: 800.876.3333 • Fax: 800.765.3435 Introduction Thank you for purchasing the Atlas Power Electrical Control Mod...
Page 6 - ECM-RACEWY Key Features
AtlasSound.com – 6 – Specifications are subject to change without notice. Owner’s Manual ECM-RACEWY ECM-20, ECM-20M, & ECM-30 1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A. Telephone: 800.876.3333 • Fax: 800.765.3435 ECM-RACEWY Key Features • ECM-RACEWY6 Holds Up To 6 ECM-20, ECM-20M, or ECM-...
Page 7 - Raceway ECM Housing; Raceway AC Inlet Knockouts
– 7 – AtlasSound.com Specifications are subject to change without notice. Owner’s Manual ECM-RACEWY ECM-20, ECM-20M, & ECM-30 1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A. Telephone: 800.876.3333 • Fax: 800.765.3435 Raceway ECM Housing The ECM-20, ECM-20M, and ECM-30 require an electrical ho...
Page 8 - Raceway AC Ground Stud; Raceway Dimensions
AtlasSound.com – 8 – Specifications are subject to change without notice. Owner’s Manual ECM-RACEWY ECM-20, ECM-20M, & ECM-30 1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A. Telephone: 800.876.3333 • Fax: 800.765.3435 Raceway AC Ground Stud The ECM-RACEWY has an internal AC Mains chassis stud ...
Page 9 - Trigger/Status Port Pin Identification
– 9 – AtlasSound.com Specifications are subject to change without notice. Owner’s Manual ECM-RACEWY ECM-20, ECM-20M, & ECM-30 1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A. Telephone: 800.876.3333 • Fax: 800.765.3435 ECM-20 & ECM-20M Front Panel Features 1. Trigger/Status Port Pin Identif...
Page 10 - ECM-30 Front Panel Features; DO NOT MISS WIRE; AC Mains Breaker
AtlasSound.com – 10 – Specifications are subject to change without notice. Owner’s Manual ECM-RACEWY ECM-20, ECM-20M, & ECM-30 1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A. Telephone: 800.876.3333 • Fax: 800.765.3435 ECM-30 Front Panel Features 1. Trigger/Status Port Pin Identification All s...
Page 11 - Internal Features of the ECM Modules; AC Spike Protection; AC Surge Protection; EVS Protection; Over Current Protection
– 11 – AtlasSound.com Specifications are subject to change without notice. Owner’s Manual ECM-RACEWY ECM-20, ECM-20M, & ECM-30 1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A. Telephone: 800.876.3333 • Fax: 800.765.3435 ECM (Electrical Control Modules) Differences Between the ECM-20 & ECM-2...
Page 12 - ECM-3BP Module Blank Cover Plate; Wiring the ECM Control Modules
AtlasSound.com – 12 – Specifications are subject to change without notice. Owner’s Manual ECM-RACEWY ECM-20, ECM-20M, & ECM-30 1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A. Telephone: 800.876.3333 • Fax: 800.765.3435 ECM-3BP Module Blank Cover Plate It is not necessary to have a module insta...
Page 13 - Example 1 - Single 20A AC Line; ECM Module Connection to an ECS-6RM Controller
– 13 – AtlasSound.com Specifications are subject to change without notice. Owner’s Manual ECM-RACEWY ECM-20, ECM-20M, & ECM-30 1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A. Telephone: 800.876.3333 • Fax: 800.765.3435 ECM-20/ECM-20M Module System Wiring Configuration Example 1 - Single 20A AC...
Page 14 - Activating an ECM via ECS-6RM Relay Contacts; ECS-6RM Wiring Configuration; Example 1
AtlasSound.com – 14 – Specifications are subject to change without notice. Owner’s Manual ECM-RACEWY ECM-20, ECM-20M, & ECM-30 1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A. Telephone: 800.876.3333 • Fax: 800.765.3435 Activating an ECM via ECS-6RM Relay Contacts Each Channel of the ECS-6RM al...
Page 15 - ECM Data Wire and Distance
– 15 – AtlasSound.com Specifications are subject to change without notice. Owner’s Manual ECM-RACEWY ECM-20, ECM-20M, & ECM-30 1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A. Telephone: 800.876.3333 • Fax: 800.765.3435 ECM Data Wire and Distance There are six ECM control ports on the ECS-6RM a...
Page 16 - ECM Troubleshooting
AtlasSound.com – 16 – Specifications are subject to change without notice. Owner’s Manual ECM-RACEWY ECM-20, ECM-20M, & ECM-30 1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A. Telephone: 800.876.3333 • Fax: 800.765.3435 ECM Troubleshooting Note: ALL TROUBLESHOOTING SHOULD BE DONE BY A CERTIFIED...
Page 17 - ECM-RACEWY Specifications
– 17 – AtlasSound.com Specifications are subject to change without notice. Owner’s Manual ECM-RACEWY ECM-20, ECM-20M, & ECM-30 1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A. Telephone: 800.876.3333 • Fax: 800.765.3435 ECM-RACEWY Specifications Type Housing for ECM-20 or ECM-20M modules Mechan...
Page 18 - Technical Data
AtlasSound.com – 18 – Specifications are subject to change without notice. Owner’s Manual ECM-RACEWY ECM-20, ECM-20M, & ECM-30 1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A. Telephone: 800.876.3333 • Fax: 800.765.3435 ECM-20/ECM-20M Specifications Type Power Conditioner Suppressor Module RoHS...
Page 19 - ECM-30 Specifications; Front Panel
– 19 – AtlasSound.com Specifications are subject to change without notice. Owner’s Manual ECM-RACEWY ECM-20, ECM-20M, & ECM-30 1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A. Telephone: 800.876.3333 • Fax: 800.765.3435 ECM-30 Specifications Type Power Conditioner Suppressor Module RoHS Complia...
Page 20 - Limited Warranty
AtlasSound.com – 20 – Specifications are subject to change without notice. Owner’s Manual ECM-RACEWY ECM-20, ECM-20M, & ECM-30 1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A. Telephone: 800.876.3333 • Fax: 800.765.3435 Limited Warranty All products manufactured by Atlas Sound are warranted to ...