Page 4 - Software Revisions; Panel Software Revision History
4 Software Revisions Current software at time of printing: Control Panel: 1.00 Bridge (Gate): 1.02 EXP-8: 1.01 RK36 LED Keypad: 4.01 Panel Software Revision History
Page 5 - Table of Contents
5 Specifications ................................................................................................................................ 6 Items Included With the Control Panel .......................................................................................... 8 Inserting the Cabinet...
Page 6 - Specifications
6 Specifications Electrical: Voltage Input: 16.5 VAC 40 VA from supplied transformer External Speaker: 10 Watt minimum, 8 Ω horn type - Ademco 713 or equivalent. Total speaker load must be between 4 Ω and 16 Ω . Internal Speaker: Speaker supplied in all compatible keypads. For stand-alone operation ...
Page 8 - Items Included With the Control Panel:
8 Items Included With the Control Panel: Please examine the contents of the shipping box for the following items: 1 - Control Panel 1 - Lock, key, and retaining clip 1 - 16.5 VAC 40 VA Transformer 9 - 4.7K Ω 1/4 Watt Resistors 1 - Auxiliary Output Harness 3 - Plastic mounting clip 1 - Microphone Har...
Page 9 - Inserting the Cabinet Lock
9 Retainer Clip (Note Position) Retainer Slot Locked Unlocked Control Board Control Board 1. Remove the cabinet door 2. Remove the lock knockout from the control cabinet door. Insert the key into the lock. Position the lock in the hole making certain thatthe latch will make contact with the latch br...
Page 11 - Wiring Notes
11 The Destiny-4100 is compatible with the ADEMCO 4140-BLK removable terminal strips. If necessary, these connectors allow for quick replacement of the control board. Wiring Notes Grounding: Ground the panel to the "com" on far left terminal block as shown in Wiring Diagram on previous page....
Page 12 - System Terminals
12 System Terminals House Phones: The R1 and T1 terminals provide telephone service to the house if the installation contains an RJ-31X terminal block for true phone line seizure. Telephone Company: The incoming telephone service is wired through an RJ-31X jack to the R and T terminals on the contro...
Page 16 - Programming; Program Mode; Locations and Values
16 Programming System options are contained in EEPROM. Each programmable section of memory has a 4 digit location and a three digit value. To reduce the amount of programming necessary, each location is supplied with a default value. The programming process can be simplified and the chances of progr...
Page 17 - Quick Start
17 Quick Start Keypad connection: Connect a hardwire keypad to the keypad terminals on the control board, be certain to properly match the colors as follows: Black to BLK , Red to RED , Green to GRN , White to WHT . Speaker connection: Connect the violet keypad speaker leads to the INT and COM termi...
Page 19 - System Setup
19 System Setup Zone 1-8 System Keypads System Board Inputs 1-8 Local Phone Panic Two Wire Smoke Loop Wireless Transmitters Zone 9 Zone 27 Zones 24 - 25 Zones 10 - 23 Hardware Device Types System Zone Assignments (Assignments may not be changed) Portable Transmitters Zone 28 Phone Line Monitor Zone ...
Page 22 - Zone 9: System Controller Two-Wire Smoke Loop
22 Zone 9 Input 2-Wire S moke Option Location Default New V al ue Default Descriptio n Zone Type 0775 255 Word 1 Word 2 Word 3 Word 4 Option 1 0771 016 Smoke (151 ) Detector (057) N/A N/A Option 2 0772 000 5819 Loop 3 Loop 2 Loop 1 (Shock Input) Loop 1 Loop 2 5816 (MN) 5817 Loop 3 Loop 2 Loop 1 Zone...
Page 24 - Zones 18 - 23: Alarm Type Transmitters Continued
24 Zones 18 - 23: Alarm Type Transmitters Continued Zone 1 8 Zone 1 9 Input Transmitter 9 Serial #: Input Transmitter 10 Serial #: Option Location Default New V al ue Option Location Default New V al ue Device 1248 005 Device 1260 005 Loop 1245 130 Loop 1257 130 Zone Type 0919 255 Zone Type 0935 255...
Page 26 - Zone 26: System Keypads
26 Zone 2 8 Input Remote Phone Option Location Default New V al ue Default Descriptio n Zone Type 1079 255 Word 1 Word 2 Word 3 Word 4 Option 1 1075 000 Remote (1 37) Phone (125) N/A N/A Option 2 1076 000 Zone 2 6 Input System Key pa ds Option Location Default New V alue 3 – Status 1334 006 6 – Moni...
Page 27 - Zone 29: Monitor Trouble Conditions; User Code + Digit Functions; System Access Codes
27 Zone 29: Monitor Trouble Conditions Option - A description of each option is available in the Glossary Location Value * Duration for recognition of AC power loss (minutes) .................................................. 0097 ....... 001 * Monitor low battery and enable battery test (001 to ena...
Page 28 - Automated Programming Locations; Assigning Words to Zones
28 Automated Programming Locations Place system in RF field strength mode and speak serial number ........................................................ 9951 Exit RF field strength mode ...................................................................................................................
Page 29 - Vocabulary
29 Vocabulary Word Location Access ..................... 024 Account .................. 025 Alarm ....................... 222 Alert ......................... 026 Am ........................... 033 And .......................... 197 Appliance ................ 027 April ........................ 227 Ar...
Page 30 - System Times And Other Options; User Code Options
30 User Code 1 2 3 4 5 6 7 8 Location 0065 0066 0067 0068 0069 0070 0071 0072 System Times And Other Options System Time Options - A description of each time is available in the Glossary Units Location Default Entry delay 1 (Not to exceed 45 seconds in a UL installation) ...............................
Page 33 - System Triggers
33 System Triggers Event Location Output Location Option Location Time Option Default Times Any alarm activation ...................................... 0122 .......... 000 ........... 0188 .......... 010 ............ 0475 ...........005 Unit disarm or as long as alarm cut off and reset Burglary .......
Page 34 - System Triggers Option; System Triggers Option Legend
34 System Triggers Option Option - Enter Total Value Activation Action Do Nothing ................................................................................................................... 000 Turn Output Off .....................................................................................
Page 35 - Automated Event Memory Log Upload; Automatic Communicator Testing
35 Automated Event Memory Log Upload Choose upload days total Location Value Sunday ........................................................................................................................................... 001 Monday ....................................................................
Page 36 - Automatic Arming and Disarming; Reporting Format
36 Fail To Open (Disarm) / Fail to Close (Arm) Options - Enter Total Location Value Enable Fail to Open ....................................................................................................................... 001 Fail to Close - Verify Armed to AWAY ......................................
Page 37 - Two-Way Digit Assignments; Two-Way Voice Options
37 Two-Way Digit Assignments This feature is not permitted in a UL installation Telephone Digit Default Function Location Default Value 0 Exit 2-way by going to keypad mode or hanging up .............................. 0162 ................... 000 1 Microphone #1 On .....................................
Page 38 - Ademco Contact ID Report Codes
38 Ademco Contact ID Report Codes APEX Description Code Sent to Central Station ADEMCO Description Exterior instant .................................. E 131 Z ............................................ Perimeter burglary Exterior delay 1 ................................. E 134 Z .....................
Page 39 - Dialer Options; Report Codes
39 Dialer Options Options - Enter total Value Dial Phone #1 ............................................................................................................... 001 Dial Phone #2 .................................................................................................................
Page 41 - Glossary of Terms
41 Glossary of Terms Access code before arm: In this configuration, a full access code (arm/disarm code) must be entered to arm the system. Once armed, the system must be disarmed to allow a change from one arming mode to another. Alarm cut off and reset: The system provides for an automatic reset (...
Page 60 - ADEMCO LIMITED WARRANTY
60 ADEMCO LIMITED WARRANTY Alarm Device Manufacturing Company, a Division Of Pittway Corporation, and its divisions, subsidiaries and affiliates(`Seller'), 165 Eileen Way, Syosset, New York 11791, warrants its products to be in conformance with its own plans andspecifications and to be free from def...