Page 2 - PRODUCT IDENTIFICATION; PBC 09 3 E 35 A X
PRODUCT IDENTIFICATION 2 The model number is used for positive identification of component parts used in manufacturing. Please use this numberwhen requesting service or parts information. PBC 09 3 E 35 A X A A BASIC MODEL TYPE MAJOR/MINOR DESIG N REV. PBC = Standard Cooler TT WPBE = Electric Heat TT...
Page 4 - PRODUCT DESIGN
PRODUCT DESIGN 4 PBC, PBE and PBH through-the-wall room air conditionersare designed for window installations in residential applica-tions and are available in 9,000 through 18,000 BTUH sizes.They are designed for 208/230/115 volt single phase applica-tions. The provided filter must be installed and...
Page 5 - SPECIFICATIONS
SPECIFICATIONS 5 PBC***E00AX MODEL PBC092E00AX PBC122E00AX PBC093E00AX PBC123E00AX Cooling (BTU's) 9200 11800 92008900 1180011400 @ EER 9.8 9.4 9. 8 9.8 Cooling W at ts 940 1260 940 - 910 1200 - 1160 Cooling Amps 8.6 11.6 4.4 - 4.7 5. 6 - 6.0 Voltage 115 115 230 -208 230 -208 Plug T ype Parallel Par...
Page 8 - PERFORMANCE DATA
8 PBC***E00AX SEN BT U H SE N BT U H SEN BT UH SE N BT UH 8 5 9 5 105 11 5 7 5 8 6 75 65 5 5 7 6 82 3 0 63 35 77 77 45 6 1 00 7 9 72 3 5 58 60 8 1 61 8 0 8 6 30 76 7 5 8 9 81 9 5 74 50 91 77 20 7 2 10 9 3 73 3 0 73 30 10 0 8 5 8 7 75 87 7 5 1 0 0 8 4 2 0 8 4 2 0 1 0 0 80 50 8 0 50 1 0 0 7 6 3 0 7 6 ...
Page 9 - PB
9 PBC***E00AX SEN BT U H SEN BT U H SEN BT U H SEN BT U H 8 5 9 5 105 115 75 83 7 5 62 55 75 79 3 0 60 35 76 74 4 5 58 00 78 69 3 5 55 60 80 61 80 83 3 0 73 75 89 78 9 5 71 50 91 74 2 0 69 10 93 70 3 0 70 30 10 0 85 84 7 5 84 75 10 0 8 1 2 0 8 1 2 0 1 0 0 77 5 0 77 50 10 0 7 3 3 0 7 3 3 0 1 0 0 75 9...
Page 15 - WIRING DIAGRAMS
15 WIRING DIAGRAMS HIGH VOLTAGE!DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THISUNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TODO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-dat...
Page 16 - WARNING
16 WIRING DIAGRAMS WARNING HIGH VOLTAGE!DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THISUNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TODO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. Wiring is subject to change, always refer to the wiring diagram on the unit for the most u...
Page 18 - TROUBLESHOOTING; ST AT US; C OR R E CT IV E AC T IO N; FJ; R epla ce or re-connect the thermos tat; CO DE
TROUBLESHOOTING ST AT US C OR R E CT IV E AC T IO N 1 F1 Outdoor ambient thermos tatnot regis tering on the board. R epla ce or re-connect the thermos tat 2 F2 Outdoor ambient thermos tatnot regis tering on the board. R epla ce or re-connect the thermos tat 3 F4 Outdoor c oil thermos tatnot regis te...