Page 2 - PRODUCT IDENTIFICATION; WARNING; C : Air Command 80 SSE Category1; CAUTION
PRODUCT IDENTIFICATION 2 Rev. 1 The model and manufacturing number are used for positive identification of component parts used in manufacturing.When engineering and manufacturing changes take place where interchangeability of components are affected, themanufacturing number will change. It is very ...
Page 3 - MODEL
PRODUCT IDENTIFICATION 3 Rev. 1 MODEL M/N MODEL M/N GUIC045CX30 P1207401FGUIC070CX30 P1207402FGUIC070CX40 P1207403FGUIC090CX30 P1207404FGUIC090CX50 P1207405FGUIC115CX40 P1207406FGUIC115CX50 P1207407FGUIC140CX50 P1207408F GUIC045CA30 P1207601FGUIC070CA30 P1207602FGUIC070CA40 P1207603FGUIC090CA30 P120...
Page 4 - PRODUCT DIMENSIONS; FURNACE
4 Rev. 1 PRODUCT DIMENSIONS GUIC 80% Upflow/Horizontal FURNACE MODEL A B C D E Minimum Vent Diameter GUIC045 GUIC070 16-1/2 15 5-1/4 12-5/8 4 4 GUIC090 20-1/2 19 7-1/4 14-5/8 4 4 GUIC115 GUIC140 24-1/2 23 9-1/4 18-5/8 4 5 GUIC DIMENSIONS All dimensions are in inches. Supply Electrical Hole "Low ...
Page 5 - GCIC DIMENSIONS
5 Rev. 1 PRODUCT DIMENSIONS GCIC 80% Counterflow/Horizontal FURNACE MODEL A B C D Unfolded E Folded Minimum Vent Diameter GCIC045 GCIC070 16-1/2 15 5/3/8 13-1/2 15 4 GCIC090 20-1/2 19 7-3/8 17-1/2 19 4 GCIC115 GCIC140 24-1/2 23 9-3/8 21-1/2 23 5 GCIC DIMENSIONS All dimensions are in inches. SUPPLY 3...
Page 6 - PRODUCT DESIGN; General Operation; High Altitude Derate
6 Rev. 1 PRODUCT DESIGN General Operation This GUIC/GCIC furnace is equipped with an electronicignition device to light the burners and an induced draftblower to exhaust combustion products. An interlock switch prevents furnace operation if the blowerdoor is not in place. Keep the blower access door...
Page 7 - PRESSURE SWITCH TRIP POINTS AND USAGE CHART
7 Rev. 1 PRODUCT DESIGN PRESSURE SWITCH (Prod.) HIGH ALTITUDE KIT TRIP POINT HIGH ALTITUDE KIT LABEL COLOR GCICGUIC 10727920 HAC1PS11 10727915 -0.41 HAC1PS12 10727916 ORANGE 0 to 6000 ft. Note: All negative pressure readings are in inches of water column (" w.c.). PRESSURE SWITCH TRIP POINTS AND...
Page 8 - ROLLOUT LIMIT SWITCHES
8 Rev. 1 PRODUCT DESIGN Part Number 10123508 or 10123527 10123509 or 10123528 10123510 or 10123529 10123511 or 10123530 10123512 or 10123531 10123513 or 10123532 Open Setting °F 260 275 300 250 325 350 Color BROWN PINK GREEN LT BLUE LT PURPLE GRAY GUIC045**30 1 GUIC070**30/40 1 GUIC090**30/50 1 GUIC...
Page 9 - Thermostats
9 Rev. 1 PRODUCT DESIGN Coil Matches: A large array of Amana coils are available for use with the GUIC and GCIC furnaces, in either upflow, counterflow, orhorizontal applications. These coils are available in both cased and uncased models, with or without a TXV expansiondevice. These 80% furnaces ma...
Page 10 - FURNACE SPECIFICATIONS
FURNACE SPECIFICATIONS 10 Rev. 1 1. These furnaces are manufactured for natural gas operation. Optional kits are available for conversion to propane gas operation. 2. For elevations above 2000 feet the rating should be reduced by 4% for each 1000 feet above sea level. The furnace must not be derated...
Page 13 - BLOWER PERFORMANCE SPECIFICATIONS; For most jobs, about 400 CFM per ton when cooling is desirable.; GUIC Blower Performance; External Static Pressure (Inches W ater Column)
BLOWER PERFORMANCE SPECIFICATIONS 13 Rev. 1 1. CFM in chart is without filters(s). Filters do not ship with this furnace, but must be provided by the installer. If the furnace requires two return filters, this chart assumes both filters are installed. 2. All furnaces ship as high speed cooling. Inst...
Page 14 - GCIC Blower Performance
BLOWER PERFORMANCE SPECIFICATIONS 14 Rev. 1 1. CFM in chart is without filters(s). Filters do not ship with this furnace, but must be provided by the installer. If the furnace requires two return filters, this chart assumes both filters are installed. 2. All furnaces ship as high speed cooling. Inst...
Page 16 - BTU OUTPUT vs TEMPERATURE RISE CHART; BTU OUTPUT
BLOWER PERFORMANCE SPECIFICA TIONS 16 Rev. 1 30 40 50 60 70 80 90 110 120 100 130 140 150 100 90 80 70 60 50 40 30 20 10 OUTPUT BTU/HR x 1000 BTU OUTPUT vs TEMPERATURE RISE CHART T E MPERAT UR E RI SE 600 CFM 700 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 CFM FORMULAS BTU OUTPUT = CFM x 1.08 x...
Page 17 - WIRING DIAGRAMS
17 Rev. 1 WIRING DIAGRAMS T O A V O ID PO S S IBL E E L E C T R IC A L S H O C K , P E R S O N A L IN J U R Y ,O R D E A T H , D IS C O NN E C T T H E P O W E R BE F O R E S E R V IC IN G . WARNING ! GUIC and GCIC (See model numbers above) YL YELLOW OR O RANGE VT VIOLET GN G REEN BK BLACK BR BROWN W...
Page 20 - GUIC (Models using WR50A55 Ignition Control)
20 Rev. 1 WIRING DIAGRAMS T O A V O ID PO S S IBL E E L E C T R IC A L S H O C K , P E R S O N A L IN J U R Y ,O R D E A T H , D IS C O NN E C T T H E P O W E R BE F O R E S E R V IC IN G . WARNING ! GUIC (Models using WR50A55 Ignition Control) YL YE L L O W OR OR A N G E VT V IO L ET GN GR E E N BK...
Page 21 - SCHEMATICS; WA; GUIC and GCIC; INE HO
21 Rev. 1 SCHEMATICS TO A V OI D P O SSI B L E ELEC TRI C A L SHOC K, PERS O NAL IN JURY , OR D E ATH, DI SCON NECT THE PO W E R B E FORE SERVI C ING. WA RN ING ! GUIC and GCIC WR50A50 INTEGRATED IGNITION CONTROL This schematic is for reference only. Not all wiring is as shown above, refer to the ap...
Page 22 - LI
22 Rev. 1 WIRING DIAGRAMS TO A V OI D P O SSI B L E ELEC TRI C A L SHOC K, PERS O NAL IN JURY , OR D E ATH, DI SCON NECT THE PO W E R B E FORE SERVI C ING. WA RN ING ! GUIC and GCIC WR50A55 INTEGRATED IGNITION CONTROL This schematic is for reference only. Not all wiring is as shown above, refer to t...