Summary

Page 2 - When raising and setting the unit,; Safe Refrigerant Handling; Never purge refrigerant into an enclosed room or; Never fill a cylinder more than 80% full of liquid re-; WARNING; Refrigerant Lines; For improved refrigerant management, equip the

2 The selected site should be no greater than 50’ below or 70’above the evaporator section. For optimum performance, theminimum length interconnecting tubing is preferred. When pos-sible minimize the amount of bends and turns. Rooftop Installations If it is necessary to install this unit on a roof s...

Page 3 - Filter Drier and Sight Glass; Burying Refrigerant Lines; IMPORTANT

3 material. Avoid suspending refrigerant tubing from joists andstuds with rigid wire or straps that would come in contact withthe tubing. Use an insulated or suspension type hanger. Keepboth lines separate and always insulate the suction line. Suct Li q Suct Li q Suct Li q 7 1/2 1 3/ 8 5/8 1 3/ 8 5/...

Page 4 - System Evacuation; Do not open valves until; REFRIGERANT UNDER PRESSURE!; and; Electrical Connections; must; Max. Voltage Deviation From

4 To avoid possible explosion, the line from thenitrogen cylinder must include a pressure regulatorand a pressure relief valve. The pressure relief valvemust be set to open at no more than 150 psig. WARNING Pressure test the system using dry nitrogen and soapy waterto locate leaks. If you wish to us...