Page 2 - PRODUCT IDENTIFICATION; WARNING
PRODUCT IDENTIFICATION 2 Rev. 1 I F R E P A I R S A R E A T T E M P T E D B Y U N Q U A L I F I E D P E R S O N S , D A N G E R -O U S C O N D I T I O N S ( S U C H A S E X P O S U R E T O E L E C T R I C A L S H O C K ) M A YR E S U L T . T H I S M A Y C A U S E S E R I O U S I N J U R Y O R D E A ...
Page 3 - MODEL
3 Rev. 1 PRODUCT IDENTIFICATION AMV90453BXA P1257401F AMV90704CXA P1257403F AMV90905DXA P1257405F AMV91155DXA P1257406F MODEL M/N MODEL M/N ACV90704CXA P1257703F ACV90905DXA P1257705F The model and manufacturing number are used for positive identification of component parts used in manufacturing.Ple...
Page 4 - PRODUCT DESIGN; Left; High Altitude Derate
4 Rev. 1 PRODUCT DESIGN 4. Installer must supply the following gas line fittings, de- pending on which entrance is used: Left -- Two 90° Elbows, one close nipple, straight pipe Right -- Straight pipe to reach gas valve. Accessibility Clearances (Minimum) POSITION* FRONT SIDES REAR TOP FLUE FLOOR Upf...
Page 5 - COMPONENT IDENTIFICATION; Counterflow /Horizontal
5 Rev. 1 COMPONENT IDENTIFICATION 1 Two-Stage Gas Valve 2 Gas Line Entrance (Alternate) 3 Pressure Switch(es) 4 Gas Manifold 5 Combustion Air Intake Connection 6 Hot Surface Igniter 7 Rollout Limit 8 Burners 9 Flame Sensor 10 Flue Pipe Connection 11 Flue Pipe 12 Combustion Air Intake (Alternate) 13 ...
Page 6 - PRODUCT DIMENSIONS; CABINET; SMALL
PRODUCT DIMENSIONS 6 Rev. 1 AMV9_____XA (Manufacturing Numbers P1257401-06F) AMV9___XA AIR DISCHARGE AIR DISCHARGE ALTERNATE GAS SUPPLY HOLE LOW VOLTAGE ELECTRICAL HOLE HIGH VOLTAGE ELECTRICAL HOLE SIDE CUT-OUT LEFT SIDE VIEW SIDE CUT-OUT HIGH VOLTAGEELECTRICAL HOLE LOW VOLTAGEELECTRICAL HOLE RIGHT ...
Page 7 - LARGE
7 Rev. 1 PRODUCT DIMENSIONS ACV9_____XA ACV9___BX__ (Manufacturing Numbers P1257703-05F) LOW VOLTAGE ELECTRICAL HOLE 28 3/4 3/4 20 1/4 2 1/2 AIR INTAKE PIPE 2" PVC LEFT SIDE DRAIN LINE HOLES DRAIN TRAP C L 28 5/16 11 1/2 9 13/16 15 1/2 UNFOLDED FLANGES 1 3/4 18 5/8 2 5/8 HIGH VOLTAGE ELECTRICAL ...
Page 8 - Part Number; Blue
8 Rev. 1 PRODUCT DESIGN Part Number 20162903 20162905 20162907 20162908 Open Setting (°F) 160 145 155 170 Color Code(s) Blue Yellow Orange Green AMV90453BXA 1 AMV90704CXA 1 AMV90905DXA 1 AMV91155DXA 1 ACV90704CXA 1 ACV90905DXA 1 T.O.D. PRIMARY LIMIT LOW FIRE HIGH FIRE LOW FIRE HIGH FIRE LOW FIRE HIG...
Page 9 - ROLLOUT LIMIT SWITCHES; AUXILIARY LIMIT SWITCHES
9 Rev. 1 PRODUCT DESIGN Part Number 10123517 10123518 10123533 10123537 Open Setting (°F) 210 170 200 190 Color Code(s) W hite Blue Yellow Gray AMV90453BXA 1 AMV90704CXA 2 AMV90905DXA 2 AMV91155DXA 2 ACV90704CXA 2 2 ACV90905DXA 2 2 ROLLOUT LIMIT SWITCHES Part Number 10123518 10123533 10123535 101235...
Page 11 - THERMOSTATS; Upflow Filters; BOTTOM RETURN; Disposable Minimum Filter Area (in; Based on a 300 ft/min filter face velocity]; Permanent Minimum Filter Area (in
11 Rev. 1 PRODUCT DESIGN Thermostats: The following Amana® brand thermostats are suggested for use with AMV9 & ACV9 Furnace Models: Thermostat Man/Auto Programmable Cool Heat Batt. Powered Batt. Bkup 1213406* Man. Or Auto Yes 2 3 No No 1213407 Man. Changeover Yes 2 2 Yes Yes 1213411 Man. Changeo...
Page 12 - Counterflow Filters; Filters can also be installed elsewhere
12 Rev. 1 PRODUCT DESIGN Counterflow Filters "A" Min Return Air Optional Access Door This furnace has provisions for the installation of return air filters at the counterflow top return. The furnace willaccommodate the following filter sizes depending on cabinet size: Refer to Minimum Filter...
Page 13 - FURNACE SPECIFICATIONS
FURNACE SPECIFICATIONS 13 Rev. 1 1. These furnaces are manufactured for natural gas operation. Optional Kits are available for conversion to propane gas operation. 2. For elevations above 2000 ft. the rating should be reduced by 4% for each 1000 ft. above sea level. The furnace must not be derated, ...
Page 15 - BLOWER PERFORMANCE SPECIFICATIONS; AMV9 Heating Speed Charts
15 Rev. 1 BLOWER PERFORMANCE SPECIFICATIONS 1. Units are shipped without filter(s). CFM in chart is without filter(s). 2. All furnaces shipped with heating speed set at "B" and cooling speed set at "D". Installer should adjust blower speed as needed. The first task is to determine th...
Page 16 - AMV9 Low Stage Cooling Speed Charts
BLOWER PERFORMANCE SPECIFICATIONS 16 Rev. 1 1. Units are shipped without filter(s). CFM in chart is without filter(s). 2. All furnaces shipped with heating speed set at "B" and cooling speed set at "D". Installer should adjust blower speed as needed. The first task is to determine th...
Page 17 - AMV9 Continuous Fan Speed Chart
BLOWER PERFORMANCE SPECIFICATIONS 17 Rev. 1 1. Units are shipped without filter(s). CFM in chart is without filter(s). 2. All furnaces shipped with heating speed set at "B" and cooling speed set at "D". Installer should adjust blower speed as needed. The first task is to determine th...
Page 18 - ACV9 Heating Speed Charts
BLOWER PERFORMANCE SPECIFICATIONS 18 Rev. 1 1. Units are shipped without filter(s). CFM in chart is without filter(s). 2. All furnaces shipped with heating speed set at "B" and cooling speed set at "D". Installer should adjust blower speed as needed. The first task is to determine th...
Page 19 - ACV9 Continuous Fan Speed Chart; The multi-speed circulator blower
BLOWER PERFORMANCE SPECIFICATIONS 19 Rev. 1 1. Units are shipped without filter(s). CFM in chart is without filter(s). 2. All furnaces shipped with heating speed set at "B" and cooling speed set at "D". Installer should adjust blower speed as needed. The first task is to determine th...
Page 20 - ACV9 High (Single) Stage Cooling Speed Charts
BLOWER PERFORMANCE SPECIFICATIONS 20 Rev. 1 1. Units are shipped without filter(s). CFM in chart is without filter(s). 2. All furnaces shipped with heating speed set at "B" and cooling speed set at "D". Installer should adjust blower speed as needed. The first task is to determine th...
Page 21 - WIRING DIAGRAMS; BTU OUTPUT vs TEMPERATURE RISE CHART; BTU OUTPUT
WIRING DIAGRAMS 21 Rev. 1 30 40 50 60 70 80 90 110 120 100 130 140 150 100 90 80 70 60 50 40 30 20 10 OUTPUT BTU/HR x 1000 BTU OUTPUT vs TEMPERATURE RISE CHART TE MPER AT UR E RI SE 600 CFM 700 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 CFM FORMULAS BTU OUTPUT = CFM x 1.08 x RISE RISE = BTU OU...
Page 23 - SCHEMATICS; BLOWER ASSEMBLY SCHEMATIC
23 Rev. 1 SCHEMATICS T O A V O ID PO S S IBLE E L E C T R IC A L S H O C K , P E R S O N A L IN J U R Y ,O R D E A T H , D IS C O NN E C T T H E P O W E R BE F O R E S E R V IC IN G . WARNING ! BLOWER ASSEMBLY SCHEMATIC AMV9/ACV9_____XA MODEL FURNACES This schematic is for reference only. Not all wi...
Page 24 - WA; TYPICAL SCHEMATIC
24 Rev. 1 SCHEMA TICS TO AV OID P O SSI B L E ELECTRI CAL SHOCK, PERSONAL I N JURY, OR DE ATH, DISCON NECT THE POW E R B E FORE SERVI C ING. WA RNING ! TYPICAL SCHEMATIC AMV9/ACV9_____XA MODEL FURNACES WR 50V61-289 INTEGRATED IGNITION CONTROL This schematic is for reference only. Not all wiring is a...