P roduct S PecificationS 2 www.amana-hac.com SS-AMV8 n omenclature Brand Revisions A Amana ® Brand A Initial ReleaseB 1st Revision Airflow Direction C 2nd Revision C Downflow/HorizontalD Dedicated DownflowH High Airflow NOx K Dedicated Upflow N Natural Gas M Upflow/Horizontal X Low NOx Description C...
Page 3 - PecificationS
P roduct S PecificationS SS-AMV8 www.amana-hac.com 3 S PecificationS AMV8 0704BXB AMV8 0905CXB AMV8 1155CXB ADV8 0703BXB ADV8 0905CXB ADV8 1155CXB H eAting C ApACity High Fire Input (BTU/h)¹ 70,000 90,000 115,000 70,000 90,000 115,000 High Fire Output (BTU/h)¹ (below) Natural Gas 57,000 74,000 93,00...
Page 4 - amV8 d; imenSionS; inimum; sw
P roduct S PecificationS 4 www.amana-hac.com SS-AMV8 amV8 d imenSionS m inimum c learanceS to c ombuStible m aterialS s iDes r eAr F ront ¹ V ent ² t op sw B 1 0 3 6 1 1 Approved for line contact in the horizontal position.¹ 24” clearance for serviceability recommended.² Single Wall Vent (SW) to be ...
Page 5 - COMPONENT IDENTIFICATION; CABINET SIZE; All dimensions are in inches.
P roduct S PecificationS SS-AMV8 www.amana-hac.com 5 adV8 d imenSionS m inimum c learanceS to c ombuStible m aterialS s iDes r eAr F ront ¹ V ent ² t op sw B 1 0 3 6 1 1 n otes Approved for line contact in the horizontal position.¹ 24” clearance for serviceability recommended.² Single Wall Vent (SW)...
Page 6 - — amV8; erformance
P roduct S PecificationS 6 www.amana-hac.com SS-AMV8 * Motor CFM maximum † Motor CFM minimum n otes • These charts are for furnaces installed at 0’ - 2,000’. At higher altitudes, a properly de-rated unit will have the same temperature rise at a particular CFM, while the ESP at that CFM will be lower...
Page 7 - ooling; – amV8
P roduct S PecificationS SS-AMV8 www.amana-hac.com 7 c ooling -b aSed c ontinuouS f an – amV8 AMV80704BXB AMV80905CXB AMV81155CXB C ooling s peeD t Ap A Djust t Ap CFM @ .1” to .8” w.C. esp C ooling s peeD t Ap A Djust t Ap CFM @ .1” to .8” w.C. esp C ooling s peeD t Ap A Djust t Ap CFM @ .1” to .8”...
Page 8 - eating
P roduct S PecificationS 8 www.amana-hac.com SS-AMV8 amV8 P erformance d ata ( cont .) H eating S PeedS AMV80704BXB (r ise r Ange : 20° - 50 °F) AMV80905CXB (r ise r Ange : 25° - 55°F) H eAting s peeD t Ap A Djust t Ap l ow s tAge CFM ¹ H igH s tAge CFM ¹ r ise ˚F H eAting s peeD t Ap A Djust t Ap l...
Page 9 - emPerature; BLOWER PERFORMANCE SPECIFICATIONS; IS
P roduct S PecificationS SS-AMV8 www.amana-hac.com 9 amV8 t emPerature r iSe c Hart BLOWER PERFORMANCE SPECIFICATIONS 15 3 0 4 0 5 0 6 0 7 0 8 0 9 0 1 1 0 1 2 0 1 0 0 1 3 0 1 4 0 1 5 0 1 0 0 9 0 8 0 7 0 6 0 5 0 4 0 3 0 2 0 1 0 O U T P U T B T U /H R x 1 0 0 0 B T U O U T P U T v s T E M P E R A T U ...
Page 13 - OUT
P roduct S PecificationS SS-AMV8 www.amana-hac.com 13 adV8 t emPerature r iSe c Hart BLOWER PERFORMANCE SPECIFICATIONS 15 3 0 4 0 5 0 6 0 7 0 8 0 9 0 1 1 0 1 2 0 1 0 0 1 3 0 1 4 0 1 5 0 1 0 0 9 0 8 0 7 0 6 0 5 0 4 0 3 0 2 0 1 0 OUT PUT BT U/H R x 1 0 0 0 B T U O U T P U T v s T E M P E R A T U R E R...
Page 14 - iring; ARNING
P roduct S PecificationS 14 www.amana-hac.com SS-AMV8 amV8 w iring d iagram W iring is subjec t to change . Alwa ys ref er to the wir ing diag ram on the unit f or the most up -t o- dat e wir ing W ARNING H igh Voltage: Disconnec t all po w er bef or e ser vicing or installing this unit. M ultiple p...
Page 16 - cceSSorieS
P roduct S PecificationS 16 www.amana-hac.com SS-AMV8 Amana ® is a trademark of Maytag Corporation or its related companies and used under license to Goodman Company, L.P. All rights reserved. Our continuing commit- ment to quality products may mean a change in specifi cations without notice. © 2009 ...