Page 2 - PRODUCT IDENTIFICATION; AF UE
PRODUCT IDENTIFICATION 2 The model and manufacturing number are used for positive identification of component parts used in manufacturing.Please use these numbers when requesting service or parts information. WARNING WARNING HIGH VOLTAGE! Disconnect ALL power before servicing or installing this unit...
Page 4 - PRODUCT DESIGN; Left; Upflow; MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS; High Altitude Derate
4 PRODUCT DESIGN 3. Conversion kits for high altitude natural or propane gas operation are available. See High Altitude Derate chartfor details. 4. Installer must supply the following gas line fittings, de- pending on which entrance is used: Left -- Two 90º Elbows, one close nipple, straight pipe. R...
Page 5 - COMPONENT IDENTIFICATION
5 COMPONENT IDENTIFICATION Upflow/Horizontal 1 Gas Valve 2 Gas Line Entrance (Alternate) 3 Pressure Switch 4 Gas Manifold 5 Combustion Air Intake Connection / “Coupling” 6 Hot Surface Igniter 7 Rollout Limit 8 Burners 9 Flame Sensor 10 Flue Pipe Connection / “Coupling” 11 Flue Pipe (Internal) 12 Pri...
Page 6 - PRODUCT DIMENSIONS
PRODUCT DIMENSIONS 6 *MH95*****XA* Note: Airflow area will be reduced by approximately 18% if duct flanges are not unfolded. This could cause performance issues and noise issues. Ca b in e t S iz e *M H 95045 3B X A * *M H 95070 3B X A * *M H 9507 04C X A * *M H 9509 04C X A * *M H 9509 05C X A * *M...
Page 8 - AUXILI ARY LIMI T SW ITCHES; Part Number; Part Number
8 PRODUCT DESIGN Part Number 10123535 10123519 0130F00038 Open Setting (°F) 150 160 120 *M H950453BXA* 1 *M H950703BXA* 1 *M H950704CXA* 1 *M H950904CXA* 1 *M H950905CXA* 1 *M H950905DXA* 1 *M H951155DXA* 1 AUXILI ARY LIMI T SW ITCHES Part Number 10123514 or 10123533 10123517 Open Setting (°F) 200 2...
Page 9 - A large array of Amana; Coil Matches (for Amana; PRODUCT
9 PRODUCT DESIGN Coil Matches: A large array of Amana ® brand and Goodman ® brand coils are available for use with the AMH95 and GMH95 furnaces, in either upflow or horizontal applications. These coils are available in both cased and uncased models (with the option of afield installed TXV expansion ...
Page 10 - Filters can also be installed elsewhere in; Upflow Filters; Disposable Minimum Filter Area (in; Based on a 300 ft/min filter face velocity]; Permanent Minimum Filter Area (in; *Minimum filter area dictated by heating airflow requirement.; BOTTOM RETURN
10 PRODUCT DESIGN Filters: Filters are required with this furnace and must be provided by the installer. The filters used must comply with UL900 orCAN/ULCS111 standards. Installing this furnace without filters will void the unit warranty. This furnace has provisions for the installation of return ai...
Page 11 - FURNACE SPECIFICATIONS
FURNACE SPECIFICATIONS 11 1. These furnaces are manufactured for natural gas operation. Optional kits are available for conversion to propane operation. 2. For elevations above 2000 feet the rating should be reduced by 4% for each 1000 feet above sea level. The furnace must not be derated, orifice c...
Page 12 - BLOWER PERFORMANCE SPECIFICATIONS; B LO WER PER FO RMAN C E
BLOWER PERFORMANCE SPECIFICATIONS 12 1. CFM in chart is without filters(s). Filters do not ship with this furnace, but must be provided by the installer. If the furnace requires two returnfilters, this chart assumes both filters are installed. 2. All furnaces ship as high speed cooling and medium-sp...
Page 13 - MP
BLOWER PERFORMANCE SPECIFICATIONS 13 30 40 50 60 70 80 90 11 0 1 2 0 10 0 13 0 1 4 0 1 5 0 10 0 90 80 70 60 50 40 30 20 10 OUT P UT BT U/H R x 1 0 0 0 BT U OUT P UT vs T E M PERAT UR E RISE CHART TE MP ERAT UR E R IS E 600 CFM 700 90 0 100 0 11 00 1 200 1 400 160 0 1 800 200 0 2 200 24 00 C F M F O ...
Page 14 - WIRING DIAGRAMS
14 WIRING DIAGRAMS Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring. HIGH VOL T A G E ! DIS C ONNECT AL L POW E R BEF O RE SERVICI NG OR IN S T A L L IN G T H IS UNIT . M U L T IPL E PO W E R SO UR CES M A Y BE P R ESEN T . F A IL URE T O DO ...