Page 2 - TABLE OF CONTENTS
MULTI-TASKER™ 400-0082-005 1 1 TABLE OF CONTENTS Page PRECAUTIONS / SAFETY WARNINGS .............. 2 GENERAL .......................................................... 2 INSTALLATION ................................................. 2 CLEANING............................................................
Page 3 - PRECAUTIONS / SAFETY WARNINGS
MULTI-TASKER™ 400-0082-005 2 2 PRECAUTIONS / SAFETY WARNINGS 1 Please read this manual carefully before using your MT104-100/103 . Keep this manual handy for future reference. These safety instructions are to ensure the long life of your MT104-100/103 and to prevent fire and shock hazard. Please rea...
Page 4 - TECHNICAL SPECIFICATIONS; DESCRIPTION; MECHANICAL
MULTI-TASKER™ 400-0082-005 3 3 ABOUT YOUR MT104-100/103 2 MT104-100 & MT104-103 6-in 1-out MT Switcher Cards The MT104-100 and MT104-103 are 6-in 1-out Video Switcher Cards. These MT Video SW cards enable 6 composite video sources to be connected and switched to a single display or recording dev...
Page 5 - Electrical
MULTI-TASKER™ 400-0082-005 4 4 ELECTRICAL MT104-100/103 Input Signals Analog +/-1.5V (1.5Vp-p) Or Digital +5V Impedance 75 Ohms Type Differential Return Loss -38dB @ 50MHz Maximum DC Offset 10mV Output Signals Gain 1.05 (+/-5%) Impedance 75 Ohms Propagation Delay (Sync) 4nS max. Rise/Fall time (Sync...
Page 6 - Use the; APPLICATION DIAGRAMS; DIAGRAM 1: RGBHV CONFIGURATION
MULTI-TASKER™ 400-0082-005 5 5 Use the MT104-100/103 card for RGBHV switching. One card is needed for each channel, for a total of 5 Video SW Cards: one card for R, one card for G, one card for B, one card for H and one card for V. Connect IN 1 of the R signal card to the R signal from a laptop, vid...
Page 8 - IN 1 OUT BNC SW + SIGNAL DETECT + EXPANDABLE + OUTPUT DISABLE; DIAGRAM 3: INTERNAL VIEW; IN 1 OUT BNC SW + OUTPUT DISABLE
MULTI-TASKER™ 400-0082-005 7 7 6 IN 1 OUT BNC SW + SIGNAL DETECT + EXPANDABLE + OUTPUT DISABLE DIAGRAM 3: INTERNAL VIEW 6 IN 1 OUT BNC SW + OUTPUT DISABLE
Page 9 - OPERATION; Use uppercase letters for all commands.
MULTI-TASKER™ 400-0082-005 8 8 INSTALLING YOUR MT104-100 6 Step 1. Slide the MT104-100/103 into an available slot in the Multi-Tasker™ Enclosure in order to connect to the bus. Make sure that the MT104-100/103 card fits into place. Secure the card to the Multi-Tasker™ by tightening the retainer scre...
Page 15 - Ci
MULTI-TASKER™ 400-0082-005 14 14 690-0122-019 = Version 019 or later. 690-0123-005 = Version 005 or later. 690-0124-019 = Version 019 or later. NOTE: In MTSetup™, send the command [VER] from the Terminal W indow. The system will respond with feedback similar to the following: [690-0122-015 690-0123-...
Page 21 - TROUBLESHOOTING GUIDE
MULTI-TASKER™ 400-0082-005 20 20 1. Select Input 2 Follow the keystrokes below to select Input 2 as the source input. Enter List available cards 04 Select MT104-100 in slot #4 1 Select CONTROL Menu 4 Select SWITCH control 2 Select Input 2 ESC Return to CONTROL Menu ESC Return to the MAIN Menu 2. Sav...
Page 22 - ALTINEX POLICY; Please see the Altinex website at
MULTI-TASKER™ 400-0082-005 21 21 Cause 2 The card and its serial device are not communicating. Solution 1: Turn the system OFF and then ON again. If there is still an error, see Solution 3. Solution 2: Call ALTINEX at (714) 990-2300. Cause 3: RS485 communication error Solution 1: Make sure that the ...