Page 3 - Electrical Safety and Emissions Standards
3 Electrical Safety and Emissions Standards This product meets the following standards. RFI Emissions FCC Class A, EN55022 Class A, EN61000-3-2, EN61000-3-3, C-TICK, CE Immunity EN55024 Electrical Safety EN60950 (TUV), UL 60950 ( C UL US ) U.S. Federal Communications Commission Radiated Energy Note:...
Page 4 - Translated Safety Statements
4 Translated Safety Statements Important: The indicates that a translation of the safety statement is available in a PDF document titled “Translated Safety Statements” (613-000405) posted on the Allied Telesis website at www.alliedtelesis.com.
Page 5 - Contents
5 Preface ................................................................................................................................................................................ 11 Safety Symbols Used in this Document.............................................................................
Page 7 - Figures
7 Figure 1. AT-GS950/16 and AT-GS950/24 Front Panels .................................................................................................... 17Figure 2. AT-GS950/16 and AT-GS950/24 Back Panels..................................................................................................
Page 9 - Tables
9 Table 1. Safety Symbols ..................................................................................................................................................... 12Table 2. System LEDs ........................................................................................................
Page 11 - Preface
11 Preface This guide contains installation instructions for the AT-GS950/16 and AT-GS950/24 Gigabit Ethernet Smart Switches. This preface contains the following sections: “Safety Symbols Used in this Document” on page 12 “Where to Find Web-based Guides” on page 13 “Contacting Allied Telesis” ...
Page 12 - Safety Symbols Used in this Document
Preface 12 Safety Symbols Used in this Document This document uses the safety symbols defined in Table 1. Table 1. Safety Symbols Symbol Meaning Description Caution Performing or omitting a specific action may result in equipment damage or loss of data. Warning Performing or omitting a specific acti...
Page 13 - Where to Find Web-based Guides
AT-GS950/16 and AT-GS950/24 Gigabit Ethernet Smart Switches Installation Guide 13 Where to Find Web-based Guides The installation and user guides for all Allied Telesis products are available in portable document format (PDF) on our web site at www.alliedtelesis.com . You can view the documents onli...
Page 14 - Contacting Allied Telesis
Preface 14 Contacting Allied Telesis This section provides Allied Telesis contact information for technical support as well as sales and corporate information. Online Support You can request technical support online by accessing the Allied Telesis Knowledge Base: www.alliedtelesis.com/support/kb.asp...
Page 15 - Chapter 1; Overview
15 Chapter 1 Overview This chapter describes the AT-GS950/16 and AT-GS950/24 Layer 2 Gigabit Ethernet Switches. The sections in the chapter are. “Features” on page 16 “Front and Back Panels” on page 17 “Ports” on page 18 “LEDs” on page 19 “Power Supply” on page 21 “Network Topologies” on...
Page 16 - Features
Chapter 1: Overview 16 Features The features of the AT-GS950/16 and AT-GS950/24 Gigabit Ethernet Switches include: LEDs for unit and port status 16 or 24 Auto-Negotiating 10/100/1000Base-T twisted pair ports with RJ-45 connectors Two small form-factor pluggable (SFP) ports Auto MDI/MDI-X on ...
Page 17 - Front and Back Panels
AT-GS950/16 and AT-GS950/24 Gigabit Ethernet Smart Switches Installation Guide 17 Front and Back Panels Figure 1 illustrates the front panels of the AT-GS950/16 and AT-GS950/24 Gigabit Ethernet Switches. Figure 1. AT-GS950/16 and AT-GS950/24 Front Panels Figure 2 illustrates the back panel of the sw...
Page 18 - Ports; Twisted Pair; Uplink Combo
Chapter 1: Overview 18 Ports The AT-GS950/16 and AT-GS950/24 Layer 2 Gigabit Ethernet Switches feature 16 or 24 twisted pair ports and two slots for optional SFP transceivers. Twisted Pair Ports The twisted pair ports are 10Base-T, 100Base-TX, and 1000Base-TX compliant. They automatically set their ...
Page 19 - LEDs
AT-GS950/16 and AT-GS950/24 Gigabit Ethernet Smart Switches Installation Guide 19 LEDs The LEDs shown in Figure 3 display system and port status information. Figure 3. AT-GS950/16 and AT-GS950/24 System and Port LEDs Table 2 describes the system LEDs. Table 3 describes the LEDs for the 10/100/1000Ba...
Page 21 - Power Supply
AT-GS950/16 and AT-GS950/24 Gigabit Ethernet Smart Switches Installation Guide 21 Power Supply The switches have an internal power supply with a single AC power supply socket on the back panel which features autoswitch AC inputs. To power the switch on or off, connect or disconnect the power cord pr...
Page 22 - Network Topologies; Power
Chapter 1: Overview 22 Network Topologies This section illustrates two network topologies of the AT-GS950/16 and AT-GS950/24 Layer 2 Gigabit Ethernet Switches: a power workgroup and collapsed backbone. Power Workgroup Topology The topology shown in Figure 4 is commonly referred to as a power workgro...
Page 25 - Chapter 2; Installation
25 Chapter 2 Installation This chapter contains the following sections: “Reviewing Safety Precautions” on page 26 “Selecting a Site for the Switch” on page 28 “Cable Specifications” on page 29 “Unpacking the Switch” on page 30 “Installing the Switch on a Desktop” on page 31 “Installing t...
Page 26 - Reviewing Safety Precautions
Chapter 2: Installation 26 Reviewing Safety Precautions Please review the following safety precautions before you begin to install the chassis or any of its components. Note The indicates that a translation of the safety statement is available in a PDF document titled “Translated Safety Statements” ...
Page 28 - Selecting a Site for the Switch
Chapter 2: Installation 28 Selecting a Site for the Switch Observe the following requirements when choosing a site for your switch: If you plan to install the switch in an equipment rack, ensure that the rack is safely secured and that it will not tip over. Devices in a rack should be installed st...
Page 29 - Cable Specifications
AT-GS950/16 and AT-GS950/24 Gigabit Ethernet Smart Switches Installation Guide 29 Cable Specifications Table 5 contains the cable specifications for the twisted pair ports. Note The twisted pair ports on the switch feature auto-MDI when operating at 10, 100 or 1000 Mbps. Each of the ports is individ...
Page 30 - Unpacking the Switch
Chapter 2: Installation 30 Unpacking the Switch To unpack the switch, perform the following procedure: 1. Remove all components from the shipping package. Note Store the packaging material in a safe location. You must use the original shipping material if you need to return the unit to Allied Telesi...
Page 31 - Installing the Switch on a Desktop
AT-GS950/16 and AT-GS950/24 Gigabit Ethernet Smart Switches Installation Guide 31 Installing the Switch on a Desktop You can install the AT-GS950/16 and AT-GS950/24 Gigabit Ethernet Smart Switches on a desktop or in a standard 19-inch equipment rack. To install the switch in a rack, refer to “Instal...
Page 32 - Installing the Switch in an Equipment Rack
Chapter 2: Installation 32 Installing the Switch in an Equipment Rack To install the switch in a standard 19-inch equipment rack, perform the following procedure: 1. If attached, remove the rubber feet using a flat-head screwdriver. 2. Install a bracket on one side of the switch using a Phillips scr...
Page 34 - Installing an Optional SFP Transceiver
Chapter 2: Installation 34 Installing an Optional SFP Transceiver The AT-GS950/16 and AT-GS950/24 Gigabit Ethernet Smart Switches have two slots for optional SFP transceivers. To install an SFP transceiver, perform the following procedure: Note The transceiver can be hot-swapped; you do not need to ...
Page 37 - Cabling the Switch
AT-GS950/16 and AT-GS950/24 Gigabit Ethernet Smart Switches Installation Guide 37 Cabling the Switch Observe the following guidelines when connecting twisted pair and fiber optic cables to the ports on the switch: The connector on the cable should fit snugly into the port on the switch. The tab on...
Page 38 - Powering On the Switch
Chapter 2: Installation 38 Powering On the Switch To power on the switch, perform the following procedure: 1. Plug the power cord into the AC power connector on the back of the switch, as shown in Figure 14. Figure 14. Plugging in the AC Power Cord 2. Plug the other end of the power cord into a wall...
Page 39 - Chapter 3; Troubleshooting
39 Chapter 3 Troubleshooting This chapter contains information on how to troubleshoot the switch if a problem occurs. Note For further assistance, please contact Allied Telesis Technical Support. Refer to “Contacting Allied Telesis” on page 14. Check the POWER LED on the front of the switch. If the ...
Page 41 - Appendix A; Technical Specifications; Physical Specifications; Power Specifications
41 Appendix A Technical Specifications Physical Specifications Dimensions: AT-GS950/16 330 mm x 230.7 mm x 43.2 mm(12.99 in x 9.08 in x 1.7 in) AT-GS950/24 440 mm x 257 mm x 43.2 mm(17.32 in x 10.12 in x 1.7 in) Weight: AT-GS950/16 2.38 kg (5.25 lbs) AT-GS950/24 3.25 kg (7.15 lbs) Environmental Spec...
Page 42 - Safety and Electromagnetic Emissions Certifications; Connectors and Port Pinouts
Appendix A: Technical Specifications 42 Safety and Electromagnetic Emissions Certifications EMI/RFI: FCC Class A, EN55022 Class A, CISPR Class A Immunity: EN55024 Electrical Safety: EN60950 (TUV), UL60950 ( c UL us) , C-TICK, CE Connectors and Port Pinouts This section lists the connectors and conne...