Page 3 - Contents
Installation and Safety Guide 3 Contents Models Covered by this Guide ...................................................................................... 4 Package Contents ............................................................................................................. 4 Selecting a ...
Page 5 - Selecting a Site
Installation and Safety Guide 5 Selecting a Site You can install the switch in the following ways: ■ in a standard 19-inch rack (see “Installing the Switch” on page 6 ) ■ on a level surface such as a desktop or bench When you install the switch, choose a site as follows: ■ for AT-8900 and AT-9900 sw...
Page 6 - Installing the Switch; Before you begin; Warning
AT-8900, AT-9900, AT-9900s Series Switches 6 Installing the Switch The switch is heavier at the rear than at the front. Therefore, we recommend that you use the supplied 19-inch rack-mount kit to fully support the switch in a rack . Using this kit is essential if the front mounting flange on the rac...
Page 7 - Installing the switch using the 19-inch rack-mount kit
Installation and Safety Guide 7 Installing the switch using the 19-inch rack-mount kit 1. Ensure the rack has sufficient space for the switch and its cables. 2. If necessary, install cage nuts at the front and rear of the rack. 3. Unpack the switch and remove the rubber feet. 4. Screw the front brac...
Page 8 - not
AT-8900, AT-9900, AT-9900s Series Switches 8 8. Fit the adjustable bracket extensions onto the rear brackets but do not tighten the nuts (see figures below). RMOUNT4a Adjustable bracket extension RMOUNT5a Adjustable bracket extension
Page 9 - Applying Power to the Switch; AC power supply
Installation and Safety Guide 9 The adjustable bracket extensions are rotationally symmetrical when attached to the rear brackets. When viewed from the rear of the switch, the flanges on the bracket extensions are at the bottom on the right and at the top on the left. This allows adequate clearance ...
Page 10 - Procedure for DC power supply; restricted access areas only
AT-8900, AT-9900, AT-9900s Series Switches 10 Procedure for DC power supply Only trained and qualified personnel should connect a DC power supply. For centralised DC power connection, the switch should be installed in restricted access areas only (such as dedicated equipment rooms or equipment close...
Page 11 - Connecting the Switch; Using the CLI to configure a switch; None
Installation and Safety Guide 11 Connecting the Switch Before you begin these procedures, ensure that the switch has at least one power supply unit installed and operating. Another power supply unit or a fan-only module must be installed in the other bay. Using the CLI to configure a switch 1. Physi...
Page 12 - Checking LEDs; LED
AT-8900, AT-9900, AT-9900s Series Switches 12 5. Change the password. Change the password as soon as possible because a manager account with the default password is a serious security risk. Remember the new password because there is no way to retrieve it if you forget it. To change the account passw...
Page 14 - Documentation CD
AT-8900, AT-9900, AT-9900s Series Switches 14 Documentation CD The documentation CD-ROM bundled with each switch contains complete documentation for your switch as well as tools to manage it. The CD includes: ■ the Hardware Reference, which provides detailed information on the switch and its hardwar...
Page 15 - Standards
Installation and Safety Guide 15 Standards This product meets the following standards: Category Approval Agency and Requirement UL60950-1CAN/CSA-C22.2 No. 60950-1-03EN60950-1AS/NZS 60950 Electromagnetic Compliance FCC CFR47 Part 15 Class AEN55022 Class AVCCI Class AAS/NZS CISPR22 Class ACNS 13438 Cl...
Page 16 - Electrical Safety Statements
AT-8900, AT-9900, AT-9900s Series Switches 16 Electrical Safety Statements Electrical Safety IMPORTANT: This equipment must be installed in accordance with safety precautions ( Safety , page 17). Elektrische Sicherheit WICHTIG: Für die Installation dieses Gerätes ist die Einhaltung von Sicherheitsvo...
Page 17 - Safety; OPERATING TEMPERATURE:
Installation and Safety Guide 17 Safety WARNING: In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. WARNING: Class 1 Laser product. WARNING: Do not stare into the laser beam. CAUTION: Use of controls or adjustments of...
Page 18 - WARNING: “Safety Hazard”; Sicherheit; WARNUNG
AT-8900, AT-9900, AT-9900s Series Switches 18 ALL COUNTRIES: Install product in accordance with local and National Electrical Codes. WARNING: For centralized DC power connection, install only in a restricted access area. A tray cable is required to connect the power source if the unit is powered by ...
Page 20 - Warnung: “Sicherheitsrisiko”; Sikkerhed; ADVARSEL
AT-8900, AT-9900, AT-9900s Series Switches 20 Hinweis: Für den Anschluß der Stromquelle ist ein für den Einsatz in Kabelrinnen geeignetes Installationskabel (Tray Cable) erforderlich, falls die Einheit durch zentralisierten Gleichstrom angetrieben wird. Das Installationskabel muß ein dem UL-Standard...
Page 22 - ALTID; Veiligheid; WAARSHUWING
AT-8900, AT-9900, AT-9900s Series Switches 22 Advarsel: INSTALLERING OG UDSKIFTNING AF DETTE UDSTYR BØR KUN UDFØRES AF AUT. EL-INSTALLATØR. Advarsel: Der bør indskydes en 15 A automatsikring på forsyningsenden af kablet til dette LAN-udstyr. Man skal ALTID først forbinde ledningerne med LAN-udstyret...
Page 24 - Sécurité; ATTENTION
AT-8900, AT-9900, AT-9900s Series Switches 24 Waarschuwing: ALLEEN GESCHOOLD EN GEKWALIFICEERD PERSONEEL MAG DEZE APPARATUUR INSTALLEREN OF VERVANGEN. Waarschuwing: Op de kabel die op de LAN-apparatuur wordt aangesloten dient een zekering van 15 amp te worden gemonteerd aan de zijde van de aansluiti...
Page 26 - Turvallisuus; VAROITUS
AT-8900, AT-9900, AT-9900s Series Switches 26 Remarque: Un câble de chariot est requis pour connecter la source de courant si l’unité est alimentée par une source de C.C. centralisée. Il doit s’agir d’un câble agréé UL de type TC, d’une puissance de 600 V et de 90 degrés C, avec trois fils conducteu...
Page 27 - Varoitus
Installation and Safety Guide 27 SALAMANISKUVAARAHENGENVAARA: ÄLÄ TYÖSKENTELE laitteiden tai KAAPELEIDEN KANSSA SALAMOINNIN AIKANA. HUOMAUTUS: VIRTAJOHTOA KÄYTETÄÄN VIRRANKATKAISULAITTEENA. VIRTA KATKAISTAAN irrottamalla virtajohto. SÄHKÖ - TYYPPILUOKAN 1 LAITTEETTÄMÄ LAITE TÄYTYY MAADOITTAA. Pistok...
Page 28 - Norme di Sicurezza; AVVERTENZA
AT-8900, AT-9900, AT-9900s Series Switches 28 Varoitus: Tämän LAN-laitteen kanssa käytettävän kaapelin syöttöpäähän tulee turvallisuussyistä asentaa 15 A virrankatkaisin. Yhdistä johdot AINA ensin LAN-laitteeseen ennen virrankatkaisimeen kytkemistä. Sähköiskusta johtuvien vammojen välttämiseksi älä ...
Page 30 - SEMPRE il cablaggio; Sikkerhet
AT-8900, AT-9900, AT-9900s Series Switches 30 Avvertenza: A titolo di cautelativo, installare un interruttore di sicurezza da 15 ampere sull’estremità in entrata del cavo di alimentazione di questa apparecchiatura LAN. Collegare SEMPRE il cablaggio prima all’apparecchiatura LAN e poi all’interruttor...
Page 32 - Advarsel: “Sikkerhetsfare”; Segurança; AVISO
AT-8900, AT-9900, AT-9900s Series Switches 32 Advarsel: Når du monterer dette utstyret, skal du alltid passe på at forbindelsen til rammejordingen monteres først og koples fra sist. Advarsel: “Sikkerhetsfare” Kontroller om uisolerte koppertråder stikker ut av den monterte ledningen. Hvis monteringen...
Page 34 - Seguridad; TEMPERATURA REQUERIDA PARA LA OPERACIÓN:
AT-8900, AT-9900, AT-9900s Series Switches 34 Aviso: “Perigo” Verifique se há algum fio de cobre exposto a sair do fio instalado. Quando esta instalação é feita correctamente não deve haver qualquer fio de cobre exposto a sair do terminal. Qualquer fio exposto pode conduzir níveis perigosos de elect...
Page 36 - Advertencia: “Riesgo de seguridad”; Säkerhet; TILLKÄNNAGIVANDEN BETRÄFFANDE ELEKTRICITETSRISK:
AT-8900, AT-9900, AT-9900s Series Switches 36 Advertencia: “Riesgo de seguridad” Cerciórese de que no haya hilos de cobre pelados que salgan del alambre instalado. Cuando dicha instalación se realiza correctamente, los hilos de cobre pelados no deben salir del bloque terminal. Todo alambre pelado pu...
Page 38 - EC Declaration of Conformity
AT-8900, AT-9900, AT-9900s Series Switches 38 EC Declaration of Conformity We: ALLIED TELESYN RESEARCH LIMITED27 NAZARETH AVENUECHRISTCHURCH 8002NEW ZEALAND Declare under our sole legal responsibility that the following product meets the safety, protection and conformity requirements of council dire...