Page 3 - WARNING
70380301 (EN) 1 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Installation must conform with local codes or, in the absence of local codes, with: In the U.S.A., installation must conform to the latest edition of the American National Standard Z223.1/NFPA 54 “National Fuel Gas C...
Page 4 - This appliance must not be installed in a bedroom or bathroom.; FOR YOUR SAFETY; AVERTISSEMENT; POUR VOTRE SÉCURITÉ
2 70380301 (EN) © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT The following information applies to the state of Massachusetts, USA. This appliance can only be installed by a Massachusetts licensed plumber or gas fitter. This appliance must be installed with a 36 inch (91 cm...
Page 5 - © Copyright 2012, Alliance Laundry Systems LLC; Table of
© Copyright 2012, Alliance Laundry Systems LLC All rights reserved. No part of the contents of this book may be reproduced or transmitted in any form or by any means without the expressed written consent of the publisher. 3 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 70380301...
Page 6 - Steam Requirements
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 4 70380301 (EN) Steam Requirements ........................................................................... 55 Piping Recommendations ..................................................................... 55Installing Steam Trap a...
Page 7 - Introduction; Model Identification
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 5 70380301 (EN) Introduction Model Identification Information in this manual is applicable to these models. Gas Steam Electric 25 Pound CHD25G2-CA025LCHD25G2-CA025NCHD25G2-CT025LCHD25G2-CT025NCHD25G2-CU025LCHD25G2-CU025NDR25G2-BA025...
Page 8 - Includes models with the following control suffixes
Introduction 70380301 (EN) 6 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Includes models with the following control suffixes : (Continued) Gas Steam Electric 35 Pound AT035LAT035NCHD35G2-CA035LCHD35G2-CA035NCHD35G2-CT035LCHD35G2-CT035NCHD35G2-CU035LCHD35G2-CU035NDR35G2-BA035L...
Page 9 - Customer Service
Introduction 7 70380301 (EN) © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Customer Service If literature or replacement parts are required, contact the source from which the machine was purchased or contact Alliance Laundry Systems at (920) 748-3950 for the name and address of...
Page 10 - Safety Information; DANGER
70380301 (EN) 8 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Safety Information Precautionary statements (“DANGER,” “WARNING,” and “CAUTION”) followed by specific instructions, are found in this manual and on machine decals. These precautions are intended for the personal safe...
Page 11 - Save These Instructions; Grounding Instructions; DO NOT DRY
Safety Information 9 70380301 (EN) © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Save These Instructions Important Safety Instructions 1. Read all instructions before using the tumble dryer. 2. Refer to the Grounding Instructions for the proper grounding of the tumble dryer. 3....
Page 12 - Installation Instructions; DO NOT
Safety Information 70380301 (EN) 10 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 22. Install this tumble dryer according to these Installation Instructions . All connections for electrical power, grounding, and gas supply must comply with local codes and be made by licensed pe...
Page 13 - Specifications and Dimensions
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 11 70380301 (EN) Specifications and Dimensions Specifications 25 Pound 30 Pound 35 Pound 55 Pound Noise level measured during operation at operator position of 3.3 feet (1 meter) in front of machine and 5.2 feet (1.6 meters) from fl...
Page 14 - Cabinet Dimensions
Specifications and Dimensions 70380301 (EN) 12 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Cabinet Dimensions * Fire suppression system optional - may not be on machine. NOTE: Facia panels available to increase height of models to 72.25 inches (183 mm) and 76.25 inches (1938 ...
Page 15 - Exhaust Outlet Locations
Specifications and Dimensions 13 70380301 (EN) © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Exhaust Outlet Locations TMB2132N B A Models Rear Exhaust Diameter A B 25/30 Pound 6 in. (152 mm) 3.875 in. (99 mm) 4.625 in. (117 mm) 35 Pound 8 in. (203 mm) 4.875 in. (124 mm) 5.625 i...
Page 16 - Gas Connection Locations
Specifications and Dimensions 70380301 (EN) 14 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Gas Connection Locations TMB2106N 1 1/2 in. NPT B C A 1 Models Gas Connection – CE and Australian Units A B C 25 Pound 59 in. (1500 mm) 1.5 in. (38.1 mm) 29 in. (737 mm) 30 Pound 59 in....
Page 17 - Electrical Connection Locations
Specifications and Dimensions 15 70380301 (EN) © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Electrical Connection Locations TMB2204N TMB2204N B D A C ELECTRIC GAS AND STEAM Models Electrical Service Gas and Steam Models Electric Models A B C D 25/30 Pound 62.25 in. (1581 mm) 2...
Page 18 - Steam Connection Locations
Specifications and Dimensions 70380301 (EN) 16 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Steam Connection Locations NOTE: All connections use 3/4 inch NPT pipe. TMB2108N C D B A Models Inlet Outlet A C B D 25/30/35 Pound 53.75 in. (1365 mm) 6.29 in. (160 mm) 42.5 in. (1080 ...
Page 19 - Installation; Pre-Installation Inspection; A typical tumble dryer enclosure is shown in
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 17 70380301 (EN) Installation Pre-Installation Inspection Upon delivery, visually inspect the crate, carton and parts for any visible shipping damage. If the crate, carton, or cover is damaged or signs of possible damage are evident...
Page 20 - Tumble Dryer Enclosure
Installation 70380301 (EN) 18 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Tumble Dryer Enclosure Figure 1 TMB2021N NOTE: Shaded areas indicate adjacent structure. 1 0.5 in. (13 mm) recommended between machines for removal or installations. 2 Allow 2-4 in. (51-102 mm) opening ...
Page 21 - Position and Level the Tumble Dryer
Installation 19 70380301 (EN) © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Position and Level the Tumble Dryer Remove lint panel door, and unscrew the four shipping bolts (one at each corner). Remove tumble dryer from skid. NOTE: Do not throw bolts away – they are the leveling...
Page 22 - To Reverse the Loading Door; Disconnect power supply to tumble dryer.
Installation 70380301 (EN) 20 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT To Reverse the Loading Door The tumble dryer is delivered with a right hinged door, but the door can be changed to a left hinged position. 1. Disconnect power supply to tumble dryer. 2. Unlock and remov...
Page 25 - Obstruction in exhaust duct. Refer to; Figure 8
Installation 23 70380301 (EN) © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Before Placing Tumble Dryer into Service 1. Remove or open all panels, and check accessible bolts, nuts, screws, terminals and fittings for tightness. 2. Replace all panels and guards. 3. Remove and dis...
Page 26 - Required for CE Models Only; Models are built in two different configurations:; Regulated Natural Gas; – Burner orifice is sized
Installation 70380301 (EN) 24 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Required for CE Models Only Once machine is installed, please be sure to complete the following items: Review and verify machine operation with customer. Leave all literature and a signed Declaratio...
Page 27 - Gases and Configurations
Installation 25 70380301 (EN) © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Gases and Configurations Country Code Gas Type Group Supply Pressure, mbar Burner Orifice Pressure, mbar Capacity/ Model Diameter, mm Quantity Burner Orifice Part No. DK/NO/ SE/FI/CZ/ EE/LV/LT/ SI/SK Na...
Page 29 - Basic Configuration; Specific Conversion Procedures
Installation 27 70380301 (EN) © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Basic Configuration 1. Determine the necessary conversion operations to convert from the factory-supplied configuration to the desired configuration. 2. Perform the conversions required so the machine i...
Page 30 - Disconnect electrical power from tumble dryer.
Installation 70380301 (EN) 28 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Specific Conversion Procedures How to Convert Gas Valve from Regulated to Unregulated NOTE: Conversion from regulated to unregulated is only needed when regulated tumble dryers were ordered, but unregul...
Page 32 - How to Change Burner Orifice Size; How to Adjust Gas Valve Governor/Regulator
Installation 70380301 (EN) 30 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT How to Change Burner Orifice Size 1. Disconnect electrical power from tumble dryer. Close gas shut-off valve to tumble dryer. Refer to Figure 9 . 2. For Johnson GM7000 gas valve: Refer to Figure 10 . Re...
Page 33 - Exhaust Requirements; Layout
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 31 70380301 (EN) Exhaust Requirements Layout Whenever possible, install tumble dryers along an outside wall where duct length can be kept to a minimum, and make-up air can be easily accessed. Elbows and long vents tend to increase d...
Page 34 - Individual Venting
Exhaust Requirements 70380301 (EN) 32 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT NOTE: Exhaust ducts must be constructed of sheet metal or other noncombustible material. Such ducts must be equivalent in strength and corrosion resistance to ducts made of galvanized sheet stee...
Page 36 - Manifold Venting; or; MUST; be
Exhaust Requirements 70380301 (EN) 34 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Manifold Venting While it is preferable to exhaust tumble dryers individually to the outdoors, a main collector duct may be used if it is sized according to Figure 14 or Figure 15 . This illustr...
Page 39 - Gas Requirements; Table 6
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 37 70380301 (EN) Gas Requirements IMPORTANT: Any product revisions or conversions must be made by the manufacturer’s authorized dealers, distributors, or local service personnel. IMPORTANT: The tumble dryer must be isolated from the...
Page 40 - Use pipe compound, resistant to
Gas Requirements 70380301 (EN) 38 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Turn on gas and check all pipe connections (internal and external) for gas leaks with a non-corrosive detection fluid. Purge air in gas service line by operating the tumble dryer in the drying mode....
Page 41 - Gas Supply Pipe Sizing and Looping
Gas Requirements 39 70380301 (EN) © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Gas Supply Pipe Sizing and Looping Figure 17 TMB2126N 1 Gas Furnace (120,000 Btu/hr.) 8 25 ft. (7.6 m) 2 Gas Water Heaters (400,000 Btu/hr. each) 9 Main Regulator 3 Gas Space Heaters (70,000 Btu/hr....
Page 43 - High Altitude Burner Orifice Sizing; Table 7
Gas Requirements 41 70380301 (EN) © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT High Altitude Burner Orifice Sizing For proper operation at altitudes above 2000 feet (610 m), the gas burner orifice size must be reduced to ensure complete combustion. Refer to Table 7 . For CE mo...
Page 44 - Electrical Requirements
70380301 (EN) 42 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Electrical Requirements Grounding Instructions NOTE: To ensure protection against shock, this tumble dryer MUST be electrically grounded in accordance with the local codes or, in the absence of local codes, with the...
Page 45 - For CE Models Only
Electrical Requirements 43 70380301 (EN) © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT This tumble dryer must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current. Th...
Page 46 - Service/Ground Location; Control Tray
Electrical Requirements 70380301 (EN) 44 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Service/Ground Location Figure 18 Model Heat Source Ground and Terminal Block Locations Non-CE Gas or Steam Non-CE Electric CE Gas or Steam CE Electric TMB2127N GroundScrew TerminalBlock Cont...
Page 47 - Connecting Electrical Service; Phase Models; prior to connecting; Conversion
Electrical Requirements 45 70380301 (EN) © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Connecting Electrical Service The following steps outline the procedure for connecting electrical service to the tumble dryer. 3 Phase Models – Each tumble dryer must be connected to its ow...
Page 48 - Conversion Instructions
Electrical Requirements 70380301 (EN) 46 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Conversion Instructions If serial plate voltage is: Tumble Dryer can be converted to the following voltages: 120 Volt/60 Hertz/1 Phase 2W&G 208-240 Volt/60 Hertz/1 Phase Models:3W&G 1...
Page 50 - Ferrite Ring Installation; Immediately after connection of power leads and
Electrical Requirements 70380301 (EN) 48 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Ferrite Ring Installation Gas and Steam Models with OM Control Suffix Only The ferrite ring provided in the literature packet must be installed over the power leads during connection of elect...
Page 51 - Refer to; For 25, 30 and 35 Pound Gas and Steam Models:
Electrical Requirements 49 70380301 (EN) © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Electrical Requirements for Gas and Steam Models Refer to Table 9 and Table 10 . NOTE: Minimum wire sizes are obtained from Canadian Electrical Code for 75°C Conductors and are intended for u...
Page 52 - For 55 Pound Gas Models:
Electrical Requirements 70380301 (EN) 50 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT For 55 Pound Gas Models: Table 10 Serial Plate Voltage Terminal Block Connections Required Current (Amps) Recommended Fuse or Breaker Rating (Amps) Breaker Poles Recommended Minimum Conductor...
Page 53 - For 9 kW 25 Pound Electric Models:
Electrical Requirements 51 70380301 (EN) © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Electrical Requirements for Electric Models Refer to Table 11 , 12, 13 and Table 14 . NOTE: Minimum wire sizes are obtained from Canadian Electrical Code Table 2 for 75°C Conductors and are i...
Page 54 - For 21 kW 30 Pound Electric Models:
Electrical Requirements 70380301 (EN) 52 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT For 21 kW 30 Pound Electric Models: Table 12 Serial Plate Voltage Terminal Block Connections Required Current (Amps) Recommended Fuse or Breaker Rating (Amps) Breaker Poles Recommended Minimu...
Page 55 - For 24 kW 35 Pound Electric Models:
Electrical Requirements 53 70380301 (EN) © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT For 24 kW 35 Pound Electric Models: Table 13 Serial Plate Voltage Terminal Block Connections Required Current (Amps) Recommended Fuse or Breaker Rating (Amps) Breaker Poles Recommended Minimu...
Page 56 - For 27 kW 55 Pound Electric Models:
Electrical Requirements 70380301 (EN) 54 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT For 27 kW 55 Pound Electric Models: Table 14 Serial Plate Voltage Terminal Block Connections Required Current (Amps) Recommended Fuse or Breaker Rating (Amps) Breaker Poles Recommended Minimu...
Page 57 - Piping Recommendations
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 55 70380301 (EN) Steam Requirements NOTE: Machines require a constant 80 to 100 psig (5.62 to 7.03 kg/sq cm) steam service for optimum operation. The maximum allowable steam pressure for use with 60 Hertz or 50 Hertz tumble dryers i...
Page 60 - Single Drop Timer; When power is applied to the tumble dryer, the; Ready Mode; Models Through Serial No. 0908xxxxx; Resetting Cycle Time to Zero
70380301 (EN) 58 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Single Drop Timer NOTE: The following information is for models with an SD control suffix only. Power-Up Mode When power is applied to the tumble dryer, the IN USE light flashes factory status information. Following...
Page 61 - Dipswitch Settings
Single Drop Timer 59 70380301 (EN) © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Dipswitch Settings Heat Time Per Coin Pulse (in minutes) Heat Switch Number 1 2 3 4 5 6 1 OFF OFF OFF OFF OFF OFF 2 ON OFF OFF OFF OFF OFF 3 OFF ON OFF OFF OFF OFF 4 ON ON OFF OFF OFF OFF 5 OFF OFF...
Page 62 - Total Cycle Time = Heat Time + Cool Down Time
Single Drop Timer 70380301 (EN) 60 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Models Through Serial No. 0908xxxxx Models Starting Serial No. 0909xxxxx Total Cycle Time = Heat Time + Cool Down Time Table 16 Table 16 (continued) Heat Time Per Coin Pulse (in minutes) Heat Switc...
Page 63 - Adjustments; Loading Door Switch; and proceed as follows:; Airflow Switch
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 61 70380301 (EN) Adjustments Loading Door Switch The door switch should be adjusted so the cylinder stops when door is opened 2 inches (51 mm) plus or minus 0.25 inch (6 mm). This switch is a normally open switch and is closed by th...
Page 64 - Door Strike; If adjustment is required, refer to
Adjustments 70380301 (EN) 62 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Door Strike The door strike must be adjusted to have sufficient tension to hold loading door closed against force of the load tumbling against it. There is proper adjustment of pull force when 8 to 15 po...
Page 65 - Removing Tumble Dryer from Service
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 63 70380301 (EN) Removing Tumble Dryer from Service If the tumble dryer is to be removed from service, perform the following steps where applicable: Turn off electrical supply external to machine. Turn off electrical disconnect ...