Page 3 - This appliance must not be installed in a bedroom or bathroom.; • WHAT TO DO IF YOU SMELL GAS:; Installation of unit must be performed by a qualified installer.; WARNING; FOR YOUR SAFETY
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 510977 1 IMPORTANT: Purchaser must consult the local gas supplier for suggested instructions to be followed if the dryer user smells gas. The gas utility instructions plus the SAFETY and WARNING note directly above must be posted in...
Page 4 - © Copyright 2010, Alliance Laundry Systems LLC; Table of; Safety Information
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT © Copyright 2010, Alliance Laundry Systems LLC All rights reserved. No part of the contents of this book may be reproduced or transmitted in any form or by any means without the expressed written consent of the publisher. 510977 2 T...
Page 5 - Maintenance
510977 3 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Step 1: Clean Lint Filter ................................................................... 35Step 2: Load Laundry....................................................................... 35Step 3: Close Loading Door .........
Page 6 - Explanation of Safety Messages; Save These Instructions; DANGER
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 4 510977 Safety Information Explanation of Safety Messages Throughout this manual and on machine decals, you will find precautionary statements (“DANGER,” “WARNING,” and “CAUTION”) followed by specific instructions. These precaution...
Page 8 - Installation; Dimensions; ELECTRIC MODELS
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 6 510977 Installation Dimensions NOTE: Side, rear and bottom exhaust openings are 4 inch (10.2 cm) ducting. Gas models cannot be vented out left side of cabinet because of burner housing. IMPORTANT: The dryer should have sufficient ...
Page 9 - Additional Security; ELECTRIC DRYERS; To change the timing cam:; for proper position.; Figure 1
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Installation 7 510977 Additional Security Torx security screws are available (as optional equipment at extra cost) for securing lower access panel to dryer base. Order part number 62853. A Torx bit, part number 282P4, is available (...
Page 10 - Coin Slide Guards; Figure 2
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Installation 510977 8 Coin Slide Guards (Coin Slide Models Only) Using sheet metal screws from accessories bag, install coin slide guard, to front of control cabinet. Refer to Figure 2 . Figure 2 NOTE: Coin slides and coin drawers a...
Page 11 - Before You Start; Tools; Figure 3; Installing the Dryer; Step 1: Position and Level the Dryer; Figure 4
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Installation 9 510977 Before You Start Tools For most installations, the basic tools you will need are: Figure 3 NOTE: An 8 in. (20.32 cm) coin drawer is required for coin operated MDC and NetMaster models. Installing the Dryer Step...
Page 12 - Figure 5; FRONT VIEW; Area; SIDE VIEW
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Installation 510977 10 Figure 5 D817I * NOTE: For new installations, locate top of wall vent 42 inches (107 cm) above floor to make venting easier to connect. 1 Outer wall of enclosure B A A C *42" (107 cm) D A E 1 FRONT VIEW (w...
Page 13 - Step 2: Connect Dryer Exhaust System; Figure 6; Use as few elbows as possible.; DO
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Installation 11 510977 Step 2: Connect Dryer Exhaust System IMPORTANT: Installing in-line filters or lint collectors will cause increased static pressure. Failure to maintain the secondary lint system will decrease dryer efficiency ...
Page 14 - Exhaust Direction; Dryer is shipped from factory ready for rear exhaust.
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Installation 510977 12 • Static pressure in exhaust duct should not be greater than .6 inches water column (1.5 cm), measured with manometer placed on exhaust duct two feet (61 cm) from dryer (check with dryer running and no load). ...
Page 15 - Exhaust System; Table 1
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Installation 13 510977 Exhaust System For best drying results, recommended maximum length of exhaust system is shown in Table 1 . To prevent backdraft when dryer is not in operation, outer end of exhaust pipe must have a weather hoo...
Page 16 - Figure 7; METERED MODELS
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Installation 510977 14 Multi-Dryer Installation Exhaust Requirements Figure 7 shows a typical example of a multiple dryer installation. Note how each dryer has its own exhaust system vented to the central exhaust duct. Figure 7 D711...
Page 17 - Figure 8
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Installation 15 510977 Figure 8 Figure 9 D686I 1 NOTE: Where the exhaust duct pierces a combustible wall or ceiling, the opening must be sized per local codes. 3 2 in. (5 cm) Minimum or Clearance per Local Codes 4 No Screen or Cap 2...
Page 18 - Make certain your dryer is equipped for use with; with a; Natural Gas; Table 2; • Use a new flexible stainless steel; Table 2
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Installation 510977 16 A Backdraft Damper, Part No. 58786 (obtain locally), should be installed in a 4 inch (10.2 cm) diameter VERTICAL duct system. This will prevent a backdraft when dryer is not in use, and will keep the exhaust a...
Page 19 - Tighten all connections securely. Turn on gas and; Altitude
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Installation 17 510977 NOTE: When connecting to a gas line, an equipment shut-off valve must be installed within 6 feet (1.8 m) of the dryer. An 1/8 in. NPT pipe plug must be installed as shown for checking inlet pressure. Refer to ...
Page 20 - Grounding Information; Amperes; (the circuit must be fused on both sides of; Electrical service for the dryer should be; Table 4; IS NOT supplied with; Type of power cord and gauge of wire must; Wire Length
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Installation 510977 18 Grounding Information This appliance must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current.Th...
Page 21 - THREE-WIRE CONNECTION
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Installation 19 510977 IMPORTANT: Use only a new U.L. listed No. 10 (copper wire only) three or four conductor power supply cord kit rated 240 Volts (minimum) 30 Amperes and labeled as suitable for use in a clothes dryer. Figure 11 ...
Page 22 - Remove access cover from rear of dryer.; Copper Wire Only
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Installation 510977 20 Connecting Power Cord with Three-Wire Plug NOTE: Four-wire cord is required for new branch-circuit installations, mobile homes or where codes do not permit grounding through neutral. Figure 13 1. Disconnect po...
Page 23 - Use the three screws from the accessories bag to; Connecting Power Cord with Four-Wire Plug
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Installation 21 510977 4. Use the three screws from the accessories bag to attach the power cord wires to the terminal block. Refer to Figure 16 . Figure 16 5. Tighten all screws firmly. IMPORTANT: Failure to tighten these screws fi...
Page 26 - Step 6: Wipe Out Inside of Dryer; Electric Dryer; Connect to 30 Amp circuit.
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Installation 510977 24 8. Using screwdriver, remove two door plugs, and reinstall on opposite side of door opening. 9. Reinstall four hinge attaching screws, removed in Step 1. Step 6: Wipe Out Inside of Dryer Before using dryer for...
Page 27 - 5 Ampere fuse; Installer Checklist; Step 9: Check Heat Source; Electric Dryers; Operation; Plug cord into separately fused 15 Amp circuit.
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Installation 25 510977 The dryer is designed to be operated on a separate branch, polarized, three-wire, effectively grounded, 120 Volt, 60 Hertz, AC (alternating current) circuit protected by a 15 Ampere fuse , equivalent fusetron ...
Page 28 - Gas Dryers
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Installation 510977 26 Gas Dryers IMPORTANT: This operation is to be conducted by qualified personnel only. To view the burner flame, remove the lower front panel of the dryer. Close the loading door, start the dryer in a heat setti...
Page 29 - Step 1: Clean Lint Filter; Clean lint filter before each use.; Step 3: Close Loading Door
27 510977 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Operation Operation Instructions for Electromechanical Dryers IMPORTANT: Before using dryer for the first time, use an all-purpose cleaner, or a detergent and water solution, and a damp cloth to remove shipping dust from i...
Page 30 - Step 4: Set Fabric Selector; Select; NORMAL; for; DELICATE; for sensitive items or; FABRIC SELECTOR
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Operation 510977 28 Step 4: Set Fabric Selector Select NORMAL for cottons, PERM PRESS for permanent press, DELICATE for sensitive items or FLUFF (NO HEAT) for items that require no heat. NOTE: Always follow manufacturer’s care label...
Page 32 - HIGH TEMP; or; NO HEAT; by pushing touchpad.; To Insert Money
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Operation 510977 30 Step 4: Set Fabric Selector Select HIGH TEMP , MED TEMP , LOW TEMP or NO HEAT by pushing touchpad. NOTE: Always follow manufacturer’s care label instructions. Figure 43 Step 5: Insert Coin(s) or Card To Insert Mo...
Page 33 - Indicator Lights
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Operation 31 510977 Indicator Lights INSERT COINS INSERT COINS is lit to prompt the user to insert coins or card to satisfy the vend price for the chosen cycle. When INSERT COINS is lit, the three digits and decimal point will displ...
Page 35 - Insert card into opening.
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Operation 33 510977 Step 4: Set Fabric Selector Select HIGH TEMP , MED TEMP , LOW TEMP or DELICATES by pushing touchpad. NOTE: Always follow manufacturer’s care label instructions. Figure 50 Step 5: Insert Coin(s) or Card To Insert ...
Page 36 - DRYING; COOL DOWN
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Operation 510977 34 Indicator Lights START START is lit whenever the dryer is not in a cycle, the full vend price has been satisfied and the dryer door is closed. When the START pad is pressed, the cycle will begin or resume. DRYING...
Page 38 - REMOVE CARD
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Operation 510977 36 Step 4: Set Fabric Selector Select HIGH TEMP , MED TEMP , LOW TEMP or NO HEAT by pushing touchpad. NOTE: Always follow manufacturer’s care label instructions. Figure 57 Step 5: Insert Coin(s) or Card To Insert Mo...
Page 40 - Lubrication; Dryer Interior; NOTE: Verify proper operation after servicing.; for lint filter
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 38 510977 Maintenance Lubrication All moving parts are sealed in a permanent supply of lubricant or are equipped with oilless bearings. Additional lubrication will not be necessary. Care of Your Dryer Dryer Interior Wipe the surface...
Page 41 - Motor Overload Protector; Make sure the lint filter is always clean.
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Maintenance 39 510977 Motor Overload Protector The dryer’s motor overload protector stops the motor automatically in the event of an overload. After cooling, the overload protector will reset itself. Dryer can be restarted by pressi...
Page 42 - Troubleshooting; Dryer Symptom; Dryer won’t start
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 40 510977 Troubleshooting Try these troubleshooting tips before making a service call. They may save you time and money. Dryer Symptom Possible Cause/Solution Dryer won’t start • Nonmetered models - Turn timer knob further into cycl...
Page 43 - Contact Information
41 510977 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Contact Information If service is required, contact the nearest Factory Authorized Service Center. If you are unable to locate an authorized service center or are unsatisfied with the service performed on your dryer, conta...
Page 46 - Fast Track for Installing the Dryer; (Refer to the manual for more detailed information); Electric
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Installer Checklist Fast Track for Installing the Dryer (Refer to the manual for more detailed information) LEVEL D255I • Position and Level the Dryer. 1 D256I CHECK D259I D255I 2 CHECK • Connect Dryer Exhaust System. D740I D740I 3 ...