Page 3 - • WHAT TO DO IF YOU SMELL GAS:; WARNING
70458101 (EN) 1 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Installation must conform with local codes or, in the absence of local codes, with:In the U.S.A., installation must conform to the latest edition of the American National Standard Z223.1/ NFPA 54 “National Fuel Gas C...
Page 4 - This appliance must not be installed in a bedroom or bathroom.
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 2 70458101 (EN) The following information applies to the state of Massachusetts, USA. This appliance can only be installed by a Massachusetts licensed plumber or gas fitter. This appliance must be installed with a 91 cm (36 inch...
Page 5 - Table of
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 70458101 (EN) 3 © Copyright 2013, Alliance Laundry Systems LLCAll rights reserved. No part of the contents of this book may be reproduced or transmitted in any form or by any means without the expressed written consent of the publis...
Page 6 - Electrical Requirements; Ignition Control Operation and Troubleshooting for; Adjustments
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 4 70458101 (EN) Electrical Requirements ..................................................................... 41 Wiring Diagram .................................................................................... 41Grounding Instruc...
Page 7 - Before You Call for Service
70458101 (EN) 5 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Before You Call for Service ............................................................... 76 Removing Tumble Dryer from Service ............................................. 76 Disposal of Unit .......................
Page 8 - Introduction; Model Identification; Information in this manual is applicable to these models:; Electric; ie
70458101 (EN) 6 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Introduction Model Identification Information in this manual is applicable to these models: Includes models with the following control suffixes: Gas. Steam/Thermal Oil Electric 120 Se ries CA120LCA120NCK120NCT120LCT1...
Page 9 - Contact Information; Alliance Laundry Systems
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Introduction 7 70458101 (EN) Contact Information If service is required, contact the nearest Factory Authorized Service Center.If you are unable to locate an authorized service center or are unsatisfied with the service performed on...
Page 10 - Safety Information; DANGER
70458101 (EN) 8 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Safety Information Precautionary statements (“DANGER,” “WARNING,” and “CAUTION”), followed by specific instructions, are found in this manual and on machine decals. These precautions are intended for the personal saf...
Page 11 - Save These Instructions; To reduce the risk of fire, electric shock,
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Safety Information 9 70458101 (EN) Save These Instructions Important Safety Instructions 1. Read all instructions before using the tumble dryer. 2. Install the tumble dryer according to the INSTALLATION instructions. Refer to the EA...
Page 13 - Specifications and Dimensions; NOTE: All machines are shipped with extra nipple
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 11 70458101 (EN) Specifications and Dimensions NOTE: All machines are shipped with extra nipple to convert to metric thread (from Standard). Specifications 120 Series 170 Series 200 Series Noise level measured during operation at op...
Page 14 - Refer to
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Specifications and Dimensions 70458101 (EN) 12 120 Series Tumble Dryer Dimensions and Exhaust Outlet Locations * Fire suppression system optional - may not be on machine. Refer to Position and Level the Tumble Dryer to temporarily r...
Page 16 - Models
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Specifications and Dimensions 70458101 (EN) 14 Electric and Gas Connection Locations for Gas Models Through 3/10/13 TMB2255N TMB2382N A C C A B B D 120L/N 170L/N D C A B D 200L/N Models Electrical Connection Gas Connection A B C D D...
Page 21 - Installation; Pre-Installation Inspection; Figure 2; All Models
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 19 70458101 (EN) Installation Pre-Installation Inspection Upon delivery, visually inspect the crate, carton and parts for any visible shipping damage. If the crate, carton, or cover is damaged or signs of possible damage are evident...
Page 23 - Position and Level the Tumble Dryer; Check Local Codes and Permits
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Installation 21 70458101 (EN) Position and Level the Tumble Dryer The tumble dryer may be moved with or without the skid. To remove the skid, unscrew the four shipping bolts, and discard them.To fit a 170 and 200 series tumble dryer...
Page 24 - Water Connections
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Installation 70458101 (EN) 22 IMPORTANT: If temperature sensors inside the tumble dryer register a temperature below 4.4°C (40°F), the fire suppression system control will lock out. This feature protects against operation of the tum...
Page 25 - Electrical power must be provided to
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Installation 23 70458101 (EN) Connect inlet hoses to water supply. Flush the lines for approximately two minutes to remove any foreign materials that could clog the screens in the water mixing valve. This is especially important whe...
Page 26 - Mo
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Installation 70458101 (EN) 24 Before Placing Tumble Dryer into Service 1. Remove or open all panels and check accessible bolts, nuts, screws, terminals and fittings for tightness. 2. Check V-belt tension and adjust if necessary. Ref...
Page 27 - IMPORTANT: The use of chlorine bleach for; Removing Tumble Dryer from Service; Required for CE Models Only; Do not operate tumble dryer if airflow
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Installation 25 70458101 (EN) 9. Check the airflow switch operation by opening the lint panel; be sure to remove shipping tape from airflow switch prior to operation. Temporarily tape down the lint panel safety switch located behind...
Page 28 - General Information; Natural Gas; Table 2
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Installation 70458101 (EN) 26 Installing CE Gas Drying Tumble Dryer General Information This information is to be used when installing gas tumble dryers in countries and/or on gases different than the machine’s factory configuration...
Page 29 - CE Orifices; Properties of CE Gases
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Installation 27 70458101 (EN) CE Orifices Table 2 Properties of CE Gases Gas Type Gas Family Group Gas Designation Supply Pressure, mbar Manifold Pressure Capacity/ Model Orifice Diameter (mm) Orifice Part Number Quantity mbar in. w...
Page 30 - asic Configuration; NOTE: Conversion from regulated to unregulated; Figure 7; NOTE: This kit does not contain any burner
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Installation 70458101 (EN) 28 B asic Configuration 1. Determine the necessary conversion operations to convert from the factory-supplied configuration to the desired configuration. 2. Perform the conversions required so the machine ...
Page 31 - How to Change Burner Orifice Size; NOTE: Blank burner orifices are Part No.; How to Adjust Gas Valve Governor/Regulator
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Installation 29 70458101 (EN) Figure 8 How to Change Burner Orifice Size 1. Disconnect electrical power from tumble dryer. Close gas shut-off valve to tumble dryer. Refer to Figure 7 . 2. Remove gas valve: Remove the burner orifice(...
Page 32 - Exhaust Requirements; Layout; IMPORTANT: Do not obstruct flow of combustion; Venting; IMPORTANT: Installing in-line filters or lint; Required Make-Up Air Opening
70458101 (EN) 30 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Exhaust Requirements Layout Whenever possible, install tumble dryers along an outside wall where duct length can be kept to a minimum, and make-up air can be easily accessed. Construction must not block the airflow ...
Page 33 - Improperly sized or assembled ductwork
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Exhaust Requirements 31 70458101 (EN) NOTE: Exhaust ducts must be constructed of sheet metal or other noncombustible material. Such ducts must be equivalent in strength and corrosion resistance to ducts made of galvanized sheet stee...
Page 34 - Individual Venting; Manifold Venting; Duct
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Exhaust Requirements 70458101 (EN) 32 Individual Venting For maximum efficiency and performance, it is preferred to exhaust tumble dryer(s) individually to the outdoors. IMPORTANT: At no point may the cross sectional area of install...
Page 35 - Consult your local building code for regulations which
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Exhaust Requirements 33 70458101 (EN) Figure 12 NOTE: Do not install wire mesh or screen in exhaust duct opening to avoid lint build-up or impacting proper discharge of air from tumble dryers. NOTE: Where exhaust duct pierces a comb...
Page 38 - Gas Requirements; Table 7
70458101 (EN) 36 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Gas Requirements IMPORTANT: Any product revisions or conversions must be made by the Manufacturer’s Authorized Dealers, Distributors or local service personnel. IMPORTANT: The tumble dryer must be isolated from the ...
Page 39 - Use pipe compound, resistant to
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Gas Requirements 37 70458101 (EN) An in-line pressure regulator may be required if the line pressure exceeds 26.1 mbar (10.5 water column inches) with all gas appliances running.LIQUID PETROLEUM GAS (L.P.) pressures with all gas app...
Page 42 - High Altitude Orifice Sizing; For proper operation at altitudes above 610 meters
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Gas Requirements 70458101 (EN) 40 High Altitude Orifice Sizing For proper operation at altitudes above 610 meters (2000 feet), the gas orifice size must be reduced to ensure complete combustion. Refer to Table 8 . For CE models, con...
Page 43 - Wiring Diagram; The wiring diagram is located in the junction or
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 41 70458101 (EN) Electrical Requirements IMPORTANT: Electrical connections must be made by a qualified electrician using data on serial plate, installation manuals and wiring diagram provided with machine and according to local code...
Page 44 - Grounding Instructions; For CE Models Only
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Electrical Requirements 70458101 (EN) 42 Grounding Instructions NOTE: To ensure protection against shock, this tumble dryer MUST be electrically grounded in accordance with the local codes, or in the absence of local codes, with the...
Page 45 - Service/Ground Location
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Electrical Requirements 43 70458101 (EN) Service/Ground Location Model Ground and Terminal Block Locations Non-CE Gas and Steam CE Gas and Steam Figure 17 (continued) Ground TMB2269N Electrical Service Terminal Block Junction Box Gr...
Page 46 - NOTE: The wiring diagram is located in the; Model
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Electrical Requirements 70458101 (EN) 44 To Connect Electrical Service To The Tumble Dryer The following steps outline the procedure for connecting the electrical service to the tumble dryer. NOTE: The wiring diagram is located in t...
Page 47 - Jumper Configuration Instructions
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Electrical Requirements 45 70458101 (EN) Jumper Configuration Instructions Changing the transformer configuration jumper is required, PRIOR TO SUPPLYING POWER TO THE MACHINE , if any of the following apply: IMPORTANT: Failure to ins...
Page 48 - Electrical Specifications; For 120 Series Gas and Steam Tumble Dryer Models; For 120 Series Electric Tumble Dryer Models
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Electrical Requirements 70458101 (EN) 46 Electrical Specifications NOTE: Minimum wire sizes are obtained from Canadian Electrical Code and are intended for use as a guideline only. Electrical connections should be made only by a qua...
Page 49 - For 200 Series Tumble Dryer Models
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Electrical Requirements 47 70458101 (EN) For 200 Series Tumble Dryer Models Serial Plate Rating Terminal Block Connections Required Rated Current* Breaker Rating Recommended Wire Size mm² (AWG) 200-208/240V/60Hz/3ph L1, L2, L3 and g...
Page 50 - Steam Requirements; (80 to 100 psig) steam service for optimum; Piping Recommendations
70458101 (EN) 48 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Steam Requirements NOTE: Machines require a constant 5.3 to 6.9 bar (80 to 100 psig) steam service for optimum operation. The maximum allowable steam pressure for use with 50 Hertz tumble dryers is 8.6 bar (125 psig...
Page 51 - IMPORTANT: Steam trap must be installed a; Thermal Oil Prep; Specifications and
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Steam Requirements 49 70458101 (EN) Installing Steam Trap and Making Condensate Return Connections The steam trap must be installed and the coil outlet connections must be connected to the condensate return lines. The following step...
Page 52 - 20 Series Tumble Dryers; Steam Pressure bar
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Steam Requirements 70458101 (EN) 50 120 Series Tumble Dryers Figure 19 Table 13 TMB2014N NOTE: Refer to Table 13 for sizing of steam lines. Piping must also be sized accordingly for length of runs and number of elbows. 1 Supply 8 45...
Page 54 - Operating Instructions
70458101 (EN) 52 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Operating Instructions Emergency Stop Button On CE Models All CE approved tumble dryers are factory equipped with an emergency stop button located on the front panel. Refer to Figure 21 . Figure 21 To operate emerge...
Page 55 - NOTE: Overloading causes slow drying and; Step 4: Remove Laundry
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Operating Instructions 53 70458101 (EN) Step 2: Load Laundry Open loading door and load cylinder with laundry. Maximum drying load for 120 models is 54.4 kg (120 pounds), for 170 models is 77.1 kg (170 pounds) and for 200 models is ...
Page 56 - Control Instructions; RQ Control Suffix; Dual Digital Timer Control; Lr; To prevent the risk of fire, remove laundry
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Operating Instructions 70458101 (EN) 54 Control Instructions RQ Control Suffix Dual Digital Timer Control 1. Select HIGH, MED, LOW or NO HEAT by turning the temperature knob.HIGH Temperature 88°C (190°F) MED Temperature 77°C (170°F)...
Page 57 - Error Codes
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Operating Instructions 55 70458101 (EN) Error Codes Display Definition Corrective Action OP Open thermistor error Check thermistor. Replace if inoperative. Check wiring diagram between control and thermistor. Refer to wiring dia...
Page 58 - Electronic OPL Micro Control; RM Control Suffix
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Operating Instructions 70458101 (EN) 56 Electronic OPL Micro Control RM Control Suffix 1. To use an Automatic Cycle, press an ON/ SELECT pad. Select HIGH, MEDIUM, MED LOW, LOW or NO HEAT for items that should not be dried with heat....
Page 59 - Reversing Operation
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Operating Instructions 57 70458101 (EN) Reversing Operation Tumble dryers with the reversing option prevent the tangling of large pieces of laundry and minimize wrinkling. These tumble dryers are equipped with a second motor and add...
Page 60 - LED OPL Control; RE Control Suffix; Programming
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Operating Instructions 70458101 (EN) 58 LED OPL Control RE Control Suffix 1. Press the Up ( ) or Down ( ) keypad to change cycles.To customize a cycle, refer to the Programming Manual . 2. Press Start ( ) to start selected cycle...
Page 61 - UniLinc Control; RU Control Suffix
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Operating Instructions 59 70458101 (EN) UniLinc Control RU Control Suffix 1. Press and keypad to change cycles. The center highlighted position is the selected cycle.To customize a cycle, refer to the Programming Manual . 2. Press S...
Page 62 - DX4 OPL Control; R3 Control Suffix; select a cycle and start the tumbler. Refer to; IMPORTANT: To stop the tumbler at any time; When the cycle is complete, open door and
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Operating Instructions 70458101 (EN) 60 DX4 OPL Control R3 Control Suffix 1. Open door and fill drum with clothes.2. Press and release one of the cycle buttons to select a cycle and start the tumbler. Refer to Table 15 . To use a cu...
Page 63 - Diagnostic Microprocessor Control; General Operation
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Operating Instructions 61 70458101 (EN) Diagnostic Microprocessor Control General Operation The Diagnostic Microprocessor Control (DMP) is designed to manage the drying and cooling cycles of the tumble dryer. The controller is also ...
Page 64 - DMP OPL Models
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Operating Instructions 70458101 (EN) 62 DMP OPL Models RD Control SuffixDescription of the OPL Control Panel Refer to Figure 35 . Figure 35 TMB1956N 1 START. Starts or resumes the current program or cycle. 2 STOP. Temporarily halts ...
Page 65 - DMP OPL Features; DIP Switch Settings; OFF; Function
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Operating Instructions 63 70458101 (EN) DMP OPL Features DIP Switch Settings The DMP has an 8 position DIP switch bank that is accessible from the back of the control board. By switching these DIP switches, it is possible for the op...
Page 66 - Nuisance shutdowns are often; off for 1/4 second during a fault condition. The; Internal Control Failure
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Operating Instructions 70458101 (EN) 64 Ignition Control Operation and Troubleshooting for Models Starting 3/11/13 Before troubleshooting the system, check the following items:- Verify all mechanical and electrical connections are s...
Page 67 - Proper Electrode Location
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Operating Instructions 65 70458101 (EN) Proper Electrode Location Proper location of the electrode assembly is important for optimal system performance. The electrode assembly should be located so that the tips are inside the flame ...
Page 69 - Gas Valve
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Operating Instructions 67 70458101 (EN) Ignition Control Operation for CE ModelsThrough 3/10/13 Power Up After 24VAC is applied to the ignition control pins 24V and GND, the Diagnostic LED on the ignition control will turn orange/ye...
Page 70 - Flame Probe Tests; Unexpected Presence of Flame
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Operating Instructions 70458101 (EN) 68 Flame Probe Tests Unexpected Presence of Flame The Unexpected Presence of Flame test is performed when no flame is expected. Failure of this test results in the ignition control entering Locko...
Page 71 - Gas Burner Air Shutter; NOTE: Air inlet shutters on the burner must be; Airflow Switch
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 69 70458101 (EN) Adjustments Gas Burner Air Shutter NOTE: Air inlet shutters on the burner must be adjusted so sufficient air is metered into the system for proper combustion and maximum efficiency. Before adjusting the inlet shutte...
Page 72 - Loading Door Switch; The tumble dryer must not be operated if
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Adjustments 70458101 (EN) 70 IMPORTANT: Airflow switch vane must remain closed during operation. If it opens and closes during the drying cycle, this indicates insufficient airflow through the tumble dryer. If switch remains open, o...
Page 73 - Loading Door Strike (200 Series; NOTE: Proper tensions for new belts are measured; Drive Motor
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Adjustments 71 70458101 (EN) Loading Door Strike (200 Series Models) The loading door strike must be adjusted to have sufficient tension to hold loading door closed against force of load tumbling against it. Proper adjustment is whe...
Page 74 - Maintenance; Daily; To reduce the risk of serious injury, do not
70458101 (EN) 72 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Maintenance Daily 1. Inspect the area surrounding tumble dryers, remove all combustible materials, including lint, before operating the machines. 2. Check cylinder for foreign objects to avoid damage to clothing and...
Page 75 - Monthly
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Maintenance 73 70458101 (EN) Monthly 1. Remove lint and debris from inside exhaust duct to maintain proper airflow and avoid overheating.a. Remove external duct and duct access covers, if present. b. Clean inside of duct with a vacu...
Page 76 - Troubleshooting; Clean up any water spilled during testing; CAUTION
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Maintenance 70458101 (EN) 74 Fire Suppression System Maintenance Test To ensure proper operation, the fire suppression system must be tested every three months. If the system test does not perform as indicated: 1. Discontinue use of...
Page 77 - IMPORTANT: If the fire suppression system failed; Dry Weight
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Maintenance 75 70458101 (EN) 8. Immediately remove and weigh the load. Refer to Table 20 for acceptable weight range. If less than minimum pounds indicated in Table 20 , the fire suppression system has failed the maintenance test. R...
Page 79 - Disposal of Unit
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 77 70458101 (EN) Disposal of Unit This appliance is marked according to the European directive 2002/96/EC on Waste Electrical and Electronic Equipment (WEEE).This symbol on the product or on its packaging indicates that this product...