Page 2 - CONTENTS; Color monitor master station; TECHNICAL DATA AND; ABOUT THIS MANUAL; Manual con
2 CONTENTS PRECAUTIONS ................................ 3 WARNING ....................................... 3CAUTION ........................................ 3GENERAL PRECAUTIONS ............ 3Notes on using this system .......... 4Notices ............................................ 4 SYSTEM CONFIGUR...
Page 3 - PRECAUTIONS; WARNING; Negligence could result in death or serious injury.; CAUTION; Negligence could result in injury to people or damage to property.; GENERAL PRECAUTIONS
3 PRECAUTIONS General Prohibitions Prohibition to Dismantle the Unit Prohibition on Subjecting the Unit to Water General Precautions WARNING Negligence could result in death or serious injury. 1. Do not dismantle or alter the unit. Fire or electric shock could result. 2. Keep the unit away from wate...
Page 4 - SYSTEM CONFIGURATIONS; ce; Entire system; Notices
4 SYSTEM CONFIGURATIONS The IS system is a commercial and security video intercom system especially designed for applications in facilities such as of fi ce buildings, factories, schools, hospitals, and prisons. Installed separately from conventional general-purpose internal communications systems, ...
Page 5 - A site must be con
5 System con fi guration examples ■ Standard (IP) system The following is an example of standard (IP) system for controlling security and communication for facilities. A site must be con fi gured with an IP-based system. • A standard (IP) system can consist of local systems and IP units. • A local s...
Page 6 - CONNECTIONS; System connection diagram; IP; Local system
6 CONNECTIONS System connection diagram The following is an example of standard (IP) system connection diagram. Refer to page 9 to 26 for details about each unit connection. * IP IS-IPC *1 IS-CCU IS-RCU IS-SCU IS-RS IS-RS IS-RS IS-MV IS-DV/IS-DVF /IS-SS IS-DV/IS-DVF /IS-SS IS-MV PT PT IS-SS IS-PU-UL...
Page 7 - or
7 IP IP IS-IPC* 1 IS-RCU IS-RS IS-IPMV IS-IPDV /IS-IPDVF IP PT IS-SS IP PS-2420/D/UL/S* 2 PS-2420/D/UL/S* 2 IS-PU-UL IS-PU-S IS-PU-UL IS-PU-S PoE PoE AC transformer Maximum number of each unit connectable to a "local system" and a site of "standard (IP) system" Category Model name Ty...
Page 8 - Cables; Notes on cables; Be sure to check the condition of cable connections with a
8 Cables Cables and connectors are not included with the products.Refer to page 9 to 26 for details about each unit connection. Notes on cables Pair4 Pair3 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Pair2 Pair1 T568A Pair4 Pair2 Pair3 Pair1 T568B How to connect or disconnect stranded wires. 8mm (3/8") Note...
Page 9 - UNIT DETAILS; Control unit common information; Accessories; Mounting bracket × 2; Mounting; Mount the unit on the wall with; Attach the mounting brackets to; Do not use screws other than the included ones.
9 UNIT DETAILS Control unit common information The information on this page is common to Central control unit (IS-CCU), Add-on control unit (IS-SCU), Room sub control unit (IS- * RCU) and IP control unit (IS-IPC). ■ Accessories ・ Mounting bracket × 2 ・ Installation manual (a booklet) *1 × 1 ・ Screw ...
Page 10 - Part names; The illustration of the unit may differ from the actual one.; Speci
10 Central control unit (IS-CCU) ■ Part names NOTE: The illustration of the unit may differ from the actual one. ■ Speci fi cations Central control unit (IS-CCU) Power source 48V DC (supplied from the power supply unit) Current consumption Max. 800mA Ambient temperature 0 - 40°C (+32°F - +104°F) Tal...
Page 11 - Connections; Output speci; Do not use the unoccupied terminals and ports for other purposes.; Input speci
11 ■ Connections 1CX1 1CX2 M1 M2 1MX1 1MX2 1MX3 2MX1 2MX2 2MX3 M3 M4 D1 D2 IP1 LAN IP2 IP3 D3 D4 2CX1 2CX2 3CX1 3CX2 4CX1 4CX2 P1 P2 P3 P4 L1 L2 L3 L4 L5 L6 L7 L8 S1 E S2 E S3 E S4 E IS-RCU MASTER STATION IS-SCU IS-IPC DC48V DOOR/SUB STATION VIDEO/AUDIO PA OUTPUT (600 Ω ) CONTACT INPUT CHIME INPUT (...
Page 12 - POWER switch
12 Add-on control unit (IS-SCU) ■ Part names NOTE: The illustration of the unit may differ from the actual one. ■ Speci fi cations Add-on control unit (IS-SCU) Power source 48V DC (supplied from the power supply unit) Current consumption Max. 1.2A Ambient temperature 0 - 40°C (+32°F - +104°F) Talk c...
Page 13 - Setting the ID setting switch
13 ■ Connections M1 M2 M3 M4 M5 M6 M7 M8 D1 D2 MX1 MX3 ID 1 2 MX2 D3 D4 D5 D6 D7 D8 P1 P2 P3 P4 L1 L2 L3 L4 MASTER STATION IS-CCU DC48V VIDEO/AUDIO DOOR/SUB STATION PA OUTPUT (600 Ω ) VIDEO OUTPUT CONTACT OUTPUT (AC/DC24V 0.5A) V1 V2 CAT5e/6 300m(980') CAT5e/6 300m(980') 15m(50') 200m(650') CAT5e/6 ...
Page 14 - CONTACT OUTPUT terminals
14 Room sub control unit (IS-RCU) ■ Part names NOTE: The illustration of the unit may differ from the actual one. ■ Speci fi cations Room sub control unit (IS-RCU) Power source 48V DC (supplied from the power supply unit) Current consumption Max. 1.8A Ambient temperature 0 - 40°C (+32°F - +104°F) Ta...
Page 18 - For the part names and their functions, see the OPERATION MANUAL.; Mounting bracket × 1
18 Color monitor master station (IS-MV) For the part names and their functions, see the OPERATION MANUAL. * ■ Accessories ・ Mounting bracket × 1 ・ Name card × 1 ・ Desktop stand × 1 ・ Screw (15mm (5/8"), for wall-mounting) × 4 ・ Tie-wrap × 1 ・ Screw (25mm (1"), for gang box) × 4 ・ Name plate ...
Page 20 - Special screwdriver × 1
20 Vandal-resistant video door station (IS-DV, IS-DVF), Vandal-resistant audio door station (IS-SS) ■ Accessories ・ Screw (for wall-mounting) × 4 (IS-DV only) ・ Special screwdriver × 1 ・ Anchor × 4 (IS-DV only) ・ Back box × 1 (IS-DVF and IS-SS only) ・ Transparent name plate × 2 (IS-DV and IS-DVF onl...
Page 21 - ABCDEFG; NOTE; Make room for threading a screw.; Use board anchors or concrete
21 ■ Mounting IS-DV (surface-mount) ABCDEFG IS-DVF ( fl ush-mount), IS-SS ( fl ush-mount) e.g.) IS-DVF Special screwdriver(included) Loosen Tighten Vandal-resistant front panel 81 mm (3-1/4'') 194 mm (7-1 1/16'') Water escape holesDo not block the holes. Ø 6 mm (Ø 1/4") 35 mm (1-3/8") Anchor...
Page 22 - The terminals are inside the terminal; Connect to the electric door strike
22 ■ Connections (IS-DV and IS-DVF) D NO COM NC PT 300m (980') D1 D4 CAT5e/6 300m (980') D1 D8 CAT5e/6 φ 0.65-1.2mm (22-16 AWG) 10m (33') φ 0.65-1.2mm (22-16 AWG) 10m (33') φ 0.65-1.2mm (22-16 AWG) 10m (33') *1: Output speci fi cations Output method N/O or N/C dry closure contact Voltage betweenterm...
Page 23 - Connect to the electric
23 ■ Connections (IS-SS) D NC COM NO PT 300m (980') D1 D4 CAT5e/6 300m (980') D1 D8 CAT5e/6 300m (980') C1 C30 CAT5e/6 φ 0.65-1.2mm (22-16 AWG) 10m (33') φ 0.65-1.2mm (22-16 AWG) 10m (33') φ 0.65-1.2mm (22-16 AWG) 10m (33') *1: Output speci fi cations Output method N/O or N/C dry closure contact Vol...
Page 24 - Fasten the mounting
24 Room sub station (IS-RS) ■ Accessories ・ Mounting bracket × 1 ・ Screw (for gang box) × 2 ・ Screw (for wall-mounting) × 2 ・ China RoHS paper × 1 ・ Tie-wrap × 1 ■ Mounting <Back wiring> <Surface wiring> When a 1-gang box is not mounted, the cable and wires can be routed to the top of th...
Page 26 - AC cord × 1 (included in the package of this power supply unit); Connect the power wires.
26 Power supply unit (IS-PU-UL and IS-PU-S) ■ Accessories ・ AC cord × 1 (included in the package of this power supply unit) ・ Precaution & mounting instruction sheet (paper) × 1 ・ China RoHS paper × 1 (IS-PU-S only) ■ Mounting ■ AC cord requirements Type: Must comply with requirements set out by...
Page 27 - TECHNICAL DATA AND PRECAUTIONS; Technical data; Operating temperature:; Technical precautions
27 TECHNICAL DATA AND PRECAUTIONS Technical data Operating temperature: • Control unit (IS-CCU, IS-SCU, IS-RCU, IS-IPC),Master station (IS-MV), Room sub station (IS-RS), Power supply unit (IS-PU-UL, IS-PU-S) 0 - 40°C (+32°F - +104°F) Door station (IS-DV, IS-DVF, IS-SS) -10 - 60°C (+14°F - +140°F) Di...
Page 28 - WARRANTY; nal decision
AIPHONE CO., LTD., NAGOYA, JAPAN AIPHONE CORPORATION, BELLEVUE, WA, USA AIPHONE S.A.S., LISSES-EVRY, FRANCE http://www.aiphone.net/ WARRANTY Aiphone warrants its products to be free from defects of material and workmanship under normal use and service for a period of two years after delivery to the ...