Page 2 - Table of Contents
Copyright 2002 Agilent Technologies. 10001810-E6701A Tutorial LAN Connection All Rights Reserved. Page 2 of 32 Rev. 1.2; Feb. 14, 2002 Table of Contents Table of Contents .......................................................................................................................... 2 Ab...
Page 4 - About This Tutorial
Copyright 2002 Agilent Technologies. 10001810-E6701A Tutorial LAN Connection All Rights Reserved. Page 4 of 32 Rev. 1.2; Feb. 14, 2002 About This Tutorial This tutorial gives you an overview of the primary features of the E6701A GPRS LabApplication. The tutorial explains how to - Make a direct con...
Page 5 - Equipment Required for this Tutorial; Test Set; Windows PC; WAP Gateway software (for data connection evaluations); RF Cable
Copyright 2002 Agilent Technologies. 10001810-E6701A Tutorial LAN Connection All Rights Reserved. Page 5 of 32 Rev. 1.2; Feb. 14, 2002 Equipment Required for this Tutorial Test Set Agilent E5515B Opt. 002 or E5515C Opt. 002 or E5515TU Opt. 002 (upgraded)If unit is E5515B, check serial number for...
Page 7 - Setup; Hardware Connections; Figure 1. PC Connected to Test Set via a LAN; Device Under Test; Personal Computer; Internet Explorer Web browser; LAN Cable; LAN
Copyright 2002 Agilent Technologies. 10001810-E6701A Tutorial LAN Connection All Rights Reserved. Page 7 of 32 Rev. 1.2; Feb. 14, 2002 Setup This section describes how to set up the hardware and software needed to use the testapplication.Note: This tutorial was written using a Motorola Timeport® p...
Page 8 - Network Setup; LAN Addresses; subnet as the test set address); Test Set Setup; Press; In the table, use the knob to choose the GPRS Lab Application
Copyright 2002 Agilent Technologies. 10001810-E6701A Tutorial LAN Connection All Rights Reserved. Page 8 of 32 Rev. 1.2; Feb. 14, 2002 Network Setup This tutorial is designed around using a Local Area Network (LAN) which is also connected tothe Internet. Your PC or your test set may already be con...
Page 9 - Set the RF In/Out Amplitude Offset; PGSM
Copyright 2002 Agilent Technologies. 10001810-E6701A Tutorial LAN Connection All Rights Reserved. Page 9 of 32 Rev. 1.2; Feb. 14, 2002 4. Find the test set’s LAN IP Address, Subnet Mask, and Default Gateway. If they arealready set to non-zero values, record their values on the lines below. 5. If t...
Page 10 - Data Conn Type; PC Setup; Windows 98 and DHCP Address
Copyright 2002 Agilent Technologies. 10001810-E6701A Tutorial LAN Connection All Rights Reserved. Page 10 of 32 Rev. 1.2; Feb. 14, 2002 For other wireless appliances, change the band and channel as necessary. 3. On the Control (left) column of softkeys, press the Data Conn Type (F4) key and change...
Page 12 - Windows 2000 and DHCP Address
Copyright 2002 Agilent Technologies. 10001810-E6701A Tutorial LAN Connection All Rights Reserved. Page 12 of 32 Rev. 1.2; Feb. 14, 2002 17. If you made changes, a System Settings Change box will appear. Select the Yes box toRestart your PC. Windows 2000 and DHCP Address 1. Turn on your PC 2. Log i...
Page 14 - Verify PC Settings; If the PC tries to access a homepage, press the Stop icon.
Copyright 2002 Agilent Technologies. 10001810-E6701A Tutorial LAN Connection All Rights Reserved. Page 14 of 32 Rev. 1.2; Feb. 14, 2002 Verify PC Settings On the PC, start the Microsoft Internet Explorer software. If you get a message saying “WorkOffline” or “Try Again”, choose the “Try Again” box...
Page 15 - Verify that Your Device Will Perform an Attach
Copyright 2002 Agilent Technologies. 10001810-E6701A Tutorial LAN Connection All Rights Reserved. Page 15 of 32 Rev. 1.2; Feb. 14, 2002 Verify that Your Device Will Perform an Attach If necessary, follow the manufacturer’s instructions to install the SIM into the device.1.1. Turn on the phone or w...
Page 16 - Set the phone’s browser to find the WAPLite homepage on your PC
Copyright 2002 Agilent Technologies. 10001810-E6701A Tutorial LAN Connection All Rights Reserved. Page 16 of 32 Rev. 1.2; Feb. 14, 2002 e. Use the number keys to enter the PC IP address (see PC Setup above for yourPC IP Address). This tells the phone where to find its primary server. i. Use the le...
Page 17 - Under Enter URL: enter the following address:; Exit the device’s browser.; Setup is now complete.
Copyright 2002 Agilent Technologies. 10001810-E6701A Tutorial LAN Connection All Rights Reserved. Page 17 of 32 Rev. 1.2; Feb. 14, 2002 3. Scroll to choose an unused http web address (or overwrite an old one). 4. Press the Menu (Edit) key 5. Under Enter URL: enter the following address: http://loc...
Page 18 - Product Feature: Screen Image Capture
Copyright 2002 Agilent Technologies. 10001810-E6701A Tutorial LAN Connection All Rights Reserved. Page 18 of 32 Rev. 1.2; Feb. 14, 2002 E6701A Features Using a LAN Connection Between the PCand Test Set Verify the following: Setup has been successfully completed (See previous section Setup) Tes...
Page 19 - Motorola Timeport Example:
Copyright 2002 Agilent Technologies. 10001810-E6701A Tutorial LAN Connection All Rights Reserved. Page 19 of 32 Rev. 1.2; Feb. 14, 2002 4. For this tutorial, select GMM/SM and GSM_L3. Make sure the other observation pointsare NOT selected. 5. The Observation Points correspond to seven protocol lay...
Page 20 - View the saved log
Copyright 2002 Agilent Technologies. 10001810-E6701A Tutorial LAN Connection All Rights Reserved. Page 20 of 32 Rev. 1.2; Feb. 14, 2002 2. On the Save Web Page window, choose a directory. 3. To more easily find your log files, point to the file icon to Create New Folder, thenselect it. 4. For this...
Page 21 - Product Feature: Ping; On the Test Set, go to the Call Setup screen.
Copyright 2002 Agilent Technologies. 10001810-E6701A Tutorial LAN Connection All Rights Reserved. Page 21 of 32 Rev. 1.2; Feb. 14, 2002 6. Watch the PC display after you press the Test Set Start / Stop Logging softkey (F1).Now turn the phone on. The PC display will update as new data is captured i...
Page 22 - If you started a protocol log, stop it and look at the data.
Copyright 2002 Agilent Technologies. 10001810-E6701A Tutorial LAN Connection All Rights Reserved. Page 22 of 32 Rev. 1.2; Feb. 14, 2002 9. Press Stop Ping (F3) key 10. If you started a protocol log, stop it and look at the data. Pinging an Alternate Device (such as your PC on the LAN)Note: You can...
Page 23 - Product Feature: Data Channel; To run the Infinite WAPlite Proxy Gateway software on your PC:
Copyright 2002 Agilent Technologies. 10001810-E6701A Tutorial LAN Connection All Rights Reserved. Page 23 of 32 Rev. 1.2; Feb. 14, 2002 Product Feature: Data Channel This is one of the most useful and powerful features of the E6701A. The Test Set acts as a GPRSbase station, for connection to one w...
Page 24 - To access a simple local file on the WAPLite gateway with the phone:
Copyright 2002 Agilent Technologies. 10001810-E6701A Tutorial LAN Connection All Rights Reserved. Page 24 of 32 Rev. 1.2; Feb. 14, 2002 local “test” data (a logo and some text) provided with the software that can be accessedby an external WAP browser. To access a simple local file on the WAPLite g...
Page 26 - Product Feature: Additional Connection Parameters; Cell Parameters – The BCH configuration can be changed as desired.; Turn the phone off; Press the More key until you see 4 of 4
Copyright 2002 Agilent Technologies. 10001810-E6701A Tutorial LAN Connection All Rights Reserved. Page 26 of 32 Rev. 1.2; Feb. 14, 2002 Product Feature: Additional Connection Parameters Cell Parameters – The BCH configuration can be changed as desired. 1. Turn the phone off 2. On the Test Set, on ...
Page 27 - Appendix A: Installing a WAP Gateway into a PC; To download the WAPlite software:
Copyright 2002 Agilent Technologies. 10001810-E6701A Tutorial LAN Connection All Rights Reserved. Page 27 of 32 Rev. 1.2; Feb. 14, 2002 Appendix A: Installing a WAP Gateway into a PC Note: Agilent Technologies does not endorse or recommend the products listed below fromvarious companies. We provid...
Page 28 - Appendix B: Troubleshooting; If the wireless device will not attach, check that:
Copyright 2002 Agilent Technologies. 10001810-E6701A Tutorial LAN Connection All Rights Reserved. Page 28 of 32 Rev. 1.2; Feb. 14, 2002 Appendix B: Troubleshooting 1. If the wireless device will not attach, check that: 1.1. Cable loss is correctly specified in RF IN/OUT Amplitude Offset table 1.2....
Page 29 - ETSI Test Mode measurements have problems:
Copyright 2002 Agilent Technologies. 10001810-E6701A Tutorial LAN Connection All Rights Reserved. Page 29 of 32 Rev. 1.2; Feb. 14, 2002 Parameters table to LLC Frame Check Sequence; change the table value toCorrupt. 2.2.3. It is possible that the mobile is capable but GMM is prioritised too low an...
Page 30 - IMPORTANT: Do not set the 4; The phone can’t access (browse) real Internet sites
Copyright 2002 Agilent Technologies. 10001810-E6701A Tutorial LAN Connection All Rights Reserved. Page 30 of 32 Rev. 1.2; Feb. 14, 2002 5.3. PC: 5.3.1. Check that the network card (if present) is fully seated in the PC Card slot. 5.3.2. Check that the LAN IP address in the PC is the same as the Te...
Page 31 - Gateway field
Copyright 2002 Agilent Technologies. 10001810-E6701A Tutorial LAN Connection All Rights Reserved. Page 31 of 32 Rev. 1.2; Feb. 14, 2002 10.2.2. On the System Configuration screen, enter a valid address into the Default Gateway field 10.3. To permanently fix the problem: 10.3.1. Upgrade the Test Se...
Page 32 - Appendix C. Glossary
Copyright 2002 Agilent Technologies. 10001810-E6701A Tutorial LAN Connection All Rights Reserved. Page 32 of 32 Rev. 1.2; Feb. 14, 2002 Appendix C. Glossary BER Bit Error Rate BLER Block Error Rate (Agilent proprietary connection mode – patent applied for) DUT Device Under Test (typically, a cellu...