Page 3 - SAFETY SUMMARY
3 SAFETY SUMMARY The following general safety precautions must be observed during all phases of operation, service, and repair of thismainframe. Failure to comply with these precautions or with specific warnings elsewhere in this guide violates safetystandards of design, manufacture, and intended us...
Page 5 - Printing History; DECLARATION OF CONFORMITY
5 Printing History The current edition of this guide is indicated below. Reprints of this guide containing minor corrections and updates mayhave the same printing date. New editions are identified by a new printing date and, in some cases, by a new part number.A new edition incorporates all new or c...
Page 6 - Table Of Contents; General Information
6 Table Of Contents 1. General Information Introduction .................................................................................................................................................. 9 Safety Considerations ............................................................................
Page 8 - Introduction; Related Documents; Safety Considerations
General Information 9 1 General Information Introduction This guide describes how to install the Agilent 66000A Modular Power System (MPS) Mainframe. It includes thefollowing information: ■ specifications and operating characteristics ■ connecting the power cord to the mainframe ■ setting the addres...
Page 9 - Options and Parts; power cord; Description
General Information 10 Options and Parts The following options are available with the mainframe: Option Description 908 Rack Mounting Kit 909 Rack Mounting Kit with handles 910 Extra Manual Set Power Cords 831 12 AWG unterminated power cord 833 1.5 mm 2 unterminated power cord 834 10 AWG unterminate...
Page 10 - General Information 11; Specifications and Supplemental Characteristics; Table 1-1. Specifications and Supplemental Characteristics
General Information 11 Specifications and Supplemental Characteristics Table 1-1 lists the specifications and supplemental characteristics of the MPS mainframe. Module specifications areincluded in the appropriate module User’s Guide. Specifications are warranted in the temperature range of 0 to 55 ...
Page 12 - Installation 13; Installation; Reference; Input Power; Line Voltage Conversion
Installation 13 2 Installation Installation When you receive your mainframe, first look for any obvious damage that could have occurred during shipment. If there isdamage, notify the carrier and the nearest Agilent Sales Office immediately. Warranty information is printed behind thecover page of thi...
Page 13 - Power Cord Installation; Figure 2-1. Power Cord Plug Configurations; Note
Installation 14 Fuses The mainframe fuse is located inside the mainframe. Refer to the mainframe Service Manual for information aboutreplacing the fuse. Power Cord Installation The power cord supplied with your mainframe may or may not include a power plug. Figure 2-1 shows the various powerplugs. R...
Page 14 - Installation 15; Location and Cooling; Bench Operation; Temperature Performance
Installation 15 Figure 2-2. Power Cord Installation Location and Cooling Bench Operation Chapter 1 gives the dimensions of your mainframe. The mainframe has plastic feet that are shaped to ensure self-alignmentwhen stacked with other Agilent System II cabinets. The feet may be removed for rack mount...
Page 15 - Rear Panel Switches; Frame Mode Switch
Installation 16 Rear Panel Switches The six-position rear panel switch is shown in the following figure. Figure 2-3. Rear Panel Switches Address Switches Address switches A0 through A4 set the primary GPIB address. The address is set in binary, A0 being the least significantbit and A4 being the most...
Page 17 - Module Installation
Installation 18 Module Installation Note A fully loaded mainframe can weigh over 36 kg (80 lbs). Install the mainframe into the rack before installing the modules into the mainframe. All modules install through the front of the mainframe. Installation (and removal) can be accomplished even when them...
Page 18 - Installation 19
Installation 19 ■ There must be no or minimal current flowing through the connector pins at the back of the modulethat is being removed. This can be accomplished by disabling the module. If this precaution isrepeatedly violated at high current, the connector pins at the back of the module will be da...
Page 19 - Connections 21; Connections; Rear Panel
Connections 21 3 Connections Rear Panel Figure 3-1 shows where all of the rear panel connections to the mainframe are made. Figure 3-1. Rear Panel Connections Module Connections Wire connections to the modules are made using a separate module connector that is supplied with each module. After themod...
Page 20 - Controller Connections; Multiple MPS Mainframes; Keyboard Connection
Connections 22 Controller Connections If you have only one MPS mainframe in your system, simply connect it to the controller using the GPIB cable. If you havemore than one mainframe, or if you also have an Agilent 667xA, 665xA, 664xA, or 603xA power supply in your system,you can use the serial-link ...
Page 21 - Connections 23
Page 22 - Trigger IN
Connections 24 Figure 3-3. Digital Connector FLT Output Used to indicate that a fault has occurred on one of the modules in the mainframe. Pins 1 and 2 (pins 1 and 2) are the open-collector output of an optocoupler, with pin 1 the collector and pin 2 the emitter. When afault has occurred, pin 1 is d...
Page 24 - Index
Index 27 Index A M addresses, 16 MAIN, 16, 22 address switch, 16 manuals, 9, 13 Agilent 603xA, 10, 11, 16, 22 module, 11, 21, 22 Agilent 664xA, 10, 11, 16, 22 module - addresses, 22 Agilent 665xA, 10, 11, 16, 22 module - connector, 21 Agilent 667xA, 10, 11, 16, 22 module - installation, 18 AUX, 16, ...
Page 25 - Agilent Sales and Support Offices; Technical data is subject to change.
Agilent Sales and Support Offices For more information about Agilent Technologies test and measurement products, applications, services,and for a current sales office listing, visit our web site: http://www.agilent.com/find/tmdir You can also contact one of the following centers and ask for a test a...
Page 26 - Manual Updates
Manual Updates The following updates have been made to this manual since the print revision indicated on the title page. 4/15/00 All references to HP have been changed to Agilent.All references to HP-IB have been changed to GPIB.