Page 2 - Selection Guide
2 Selection Guide Figure 1. 2 + 16-channel mixed signal oscilloscope (MSO) family shown with 2- and 4-channel models. Selection Guide Model Bandwidth Maximum Sample Rate Maximum Memory* Channels 54621A 60 MHz 200 MSa/s 4 MB 2 54621D 60 MHz 200 MSa/s 4 MB 2+16 54622A 100 MHz 200 MSa/s 4 MB 2 54622D 1...
Page 4 - Affordable and Responsive; MegaZoom deep memory
4 Affordable and Responsive MegaZoom deep memory With 4 MB to 8 MB of MegaZoomdeep memory, 54600-Seriesscopes give you deep-memorycapture without the sluggishresponse and complex operationyou’ve had to tolerate with otherdeep-memory scopes. And unlikethe alternatives, MegaZoom deepmemory is not a sp...
Page 5 - Standard features; Parallel and RS-232 interfaces; Built-in floppy drive
5 Affordable and Responsive (continued) Revolutionary high-definition dis-play helps you see details Combine MegaZoom deep memorywith a patented high-definition display system, and you will seesubtle details that most scopeswon’t show you. The MegaZoomdeep memory is mapped into 32levels of intensity...
Page 6 - Other standard features; Waveform math with FFTs:
6 Deep memory transfer over the bus Transfer all of your data over thebus, even when using deep memory. Typical transfer time is <70 seconds for 2 MB of data over GPIB. The 54640-Series requires soft-ware revision 1.0 or later. The54620-Series requires softwarerevision 1.5 or later. The systemsof...
Page 7 - • sort through frame traffic on
7 N2758A CAN Trigger Module • Trigger on CAN 2.0A/B message frames with user specified IDsand/or data • Trigger on Error frames • Differential CAN • Acknowledge On/Off • Built In QuickHelp • Remote Control via GPIB/RS232 • Compatible with 54621D, 54622D, 54641D, 54642D The N2758A CAN trigger modulee...
Page 8 - Triggering; Flexible Triggering
8 Triggering Flexible Triggering With mixed analog and digitaldesigns, sometimes it is hard totrace an anomaly back to its rootcause unless you can trigger on itand correlate it with another signal. With the 54600-Seriesscopes, triggering is no longer ahassle. They come with f lexibletriggering capa...
Page 9 - C and SPI Triggering; C) or Serial Peripheral; Figure 7. Trigger on data patterns within a SPI frame.; The full range of I
9 Triggering (continued) I 2 C and SPI Triggering Don’t spend your time sortingthrough communication frames tofind the one of interest. LetAgilent set up an Inter-IntegratedCircuit (I 2 C) or Serial Peripheral Interface (SPI) trigger to siftthrough the frames for you. Andlike the CAN, LIN, and USB t...
Page 12 - Probes; Agilent Passive Probes Selection Guide
12 Probes To get the most out of your scope,you need the right probes andaccessories for your particularapplication. That's why AgilentTechnologies offers a completefamily of innovative probes and54600-Series scopes. For morecomprehensive information,please see the Agilent54600-Series OscilloscopesP...
Page 13 - Performance Characteristics
13 Performance Characteristics Acquisition: Analog Channels Max Sample Rate 54621A/D, 54622A/D, 54624A: 200 MSa/s54641A/D, 54642A/D: 2 GSa/sec interleaved, 1 GSa/sec each channel Max Memory Depth 54621A/D, 54622A/D, 54624A: 4 MB interleaved, 2 MB each channel54641A/D, 54642A/D: 8 MB interleaved, 4 M...
Page 21 - Ordering Information
21 Ordering Information Description 54621A 2-channel 60 MHz Oscilloscope 54621D 2+16 channel 60 MHz Mixed Signal Oscilloscope 54622A 2-channel 100 MHz Oscilloscope 54622D 2+16 channel 100 MHz Mixed Signal Oscilloscope 54624A 4-channel 100 MHz Oscilloscope 54641A 2-channel 350 MHz Oscilloscope 54641D...