Page 2 - Technology transfers reliable power
● ! History of establishment and innovation - In 1883, Mr. Rathenau established the AEG company to p r o d u c e l i g h t b u l b s i n B e r l i n , G e r m a n y . S o o n , t h e company began to produce low-voltage electrical devices and transmission & distribution products, which had first...
Page 3 - We are striving to create a; Main distribution system
● ! History of establishment and innovation - In 1883, Mr. Rathenau established the AEG company to p r o d u c e l i g h t b u l b s i n B e r l i n , G e r m a n y . S o o n , t h e company began to produce low-voltage electrical devices and transmission & distribution products, which had first...
Page 4 - Catalogue
C at al og ue 1 Technology transfers reliable power A. A.1 A.3 A.5 A.6 A.7 B. B.1 B.5 B.6 B.6 B.16 C. C.1 C.2 C.3 C.3 C.5 ACB's series ME09 Characteristics Performance Selection Guide Quick Selection Table Curves MCCB's series MM9/MC9 Characteristics Performance Selection Guide Quick Selection Table...
Page 5 - Characteristics; years, our products will meet requirements of Chinese market.; NEW
A.1 A ir C irc uit B re ak er A Technology transfers reliable power Frame current Catalogs In A 400 ~ 4000 Frame, Cat. No 1 2 Dimensions Fixed W 3P/4P 342/442 432/562 D 3P/4P 352 H 3P/4P 430 Draw-out W 3P/4P 329/429 419/549 D 3P/4P 422 H 3P/4P 440 ACB's series ME09 Characteristics ■ Combining experi...
Page 6 - Powerful communication function; MPRO
A.2 A ir C irc ui t B re ak er A Technology transfers reliable power ■ Powerful M-PRO intellectual trip unit has covered global requirements of clients and supplied clients with understandable and easy-to-use interface. Overload protection • Short-circuit protection • Multi-functional ground-fault p...
Page 7 - Special thermal memory function
A.3 A ir C irc uit B re ak er A Technology transfers reliable power ■ Excellent structural design and material usage ensure working stably over 40 ℃ Ambient Rated current Temperature 800A 1000A 1250A 1600A 2000A 2500A 3200A 4000A 40 ℃ 800A 1000A 1250A 1600A 2000A 2500A 3200A 4000A 50 ℃ 800A 1000A 12...
Page 8 - Performance
A.4 A ir C irc ui t B re ak er A Technology transfers reliable power Performance Frame Current Type In A 400 800 1000 Standard GB 14048.2/IEC60947-1.2.3/VDE0660's 101 and107 / BS EN60947-2 Ranges of Rated Current(40 ℃ ) A 160-400 320-800 400-1000 Rated Service Voltage Ue V 690 Rated Insulating Volta...
Page 10 - Control Unit; Selection Guide
A.6 A ir C irc ui t B re ak er A Technology transfers reliable power ME09 ACB's low voltage ME09 3 No. of poles : 3:3pole 4:4pole 1 Frame : 1: Frame 1 2: Frame 2 W Mounting form : F: Fixed W: Draw- out D Breaking capacity (kA) (voltage @AC415V) : A:lcu=50,lcs=50,lcw=50(1s) D:lcu=70,lcs=65,lcw=65(1s)...
Page 11 - Auxiliary; Quick Selection Table
A.7 A ir C irc uit B re ak er A Technology transfers reliable power Auxiliary • Parent Breaker • Rated Current In(A) 400 800 1000 1250 1600 2000 2500 3200 4000 B re ak in g ca pa ci ty A Fixed 3P ME09A31F04 ME09A31F08 ME09A31F10 ME09A31F12 ME09A31F16 ME09A31F20 ME09A31F25 ME09A32F32 ME09A32F40 4P ME...
Page 12 - Curves
A.8 A ir C irc ui t B re ak er A Technology transfers reliable power Long-time delayShort-time delaySimultaneousMagnification Current×lset Trip time (s) Long-time delayShort-time delaySimultaneousMagnification Trip time (s) Current×lset lset times of current Trip time (s) Long-time delayShort-time d...
Page 14 - different circumstances and industries.
M ou ld ed C as e C irc ui t-b re ak er B B.1 Technology transfers reliable power ■ Excellent overall breaking capacity offers clients more options and can meet requirements of different circumstances and industries. MM169 AC 415V MC169/259 MC409/639 Ics=100%Icu ■ The current of this series is up to...
Page 15 - Dual contacts rotary configuration.
M ou ld ed C as e C irc uit -b re ak er B B.2 Technology transfers reliable power ■ Excellent circumstance adaption capacity guarantees reliable operation in rigid environment. Operating temperature -20~+70 ℃ Storage temperature -40~+85 ℃ Up to altitudes of 2000 m above sea level no derating of brea...
Page 16 - Selective thermal and magnetic protection (S); Complete trip unit protection will meet all clients' requirement.
M ou ld ed C as e C irc ui t-b re ak er B B.3 Technology transfers reliable power M Without overload protection (line stands for breakers’ thermal endurance) Short-circuit protection without time-delay Rapid trip unit Current Tim e Selective thermal and magnetic protection (S) • For MC169/259 frame ...
Page 17 - Selective thermal and magnetic protection (E); ln
M ou ld ed C as e C irc uit -b re ak er B B.4 Technology transfers reliable power RPS43250-250 E Overload protection to motors or lines(LT) Time-delay short-circuit protection (depending on current) Filtered high electronic level(1) short-circuit protection Rapid trip unit Current Time Selective the...
Page 18 - In, 6 time settings, 2 used for motors and 4 used for line
M ou ld ed C as e C irc ui t-b re ak er B B.5 Technology transfers reliable power RPA43400-400 MC639-F F Multiple overload protections(LT) time delay ranges(LTD) filtered high electronic short-circuit protection Multiple short-circuit protection(ST) time delay ranges(STD) or energy curve(I 2 T) Rapi...
Page 19 - Extended modules of F tripping unit
M ou ld ed C as e C irc uit -b re ak er B B.6 Technology transfers reliable power Extended modules of F tripping unit • Each F device can be equipped with two plug-in elements, a rating plug and an extension module. The extension modules are simple plug-in devices that allow the user to enhance the ...
Page 21 - Thermal and magnetic trip unit; Fixed breakers; Electronic trip unit; Fixed Breakers
M ou ld ed C as e C irc uit -b re ak er B B.8 Technology transfers reliable power ■ Excellent structure design and material usage ensure the devices working reliably over 40 ℃ . Thermal and magnetic trip unit • Maximum Allowed Current Under the Following Ambient Temperatures Type Fixed breakers plug...
Page 24 - Breaker Selection Guide; MM
M ou ld ed C as e C irc ui t-b re ak er B B.11 Technology transfers reliable power Breaker Selection Guide MM Frame : MM:160A MC:160-630A 3 No. of poles : 3:3pole 4:4pole F Mounting format : F:fixed P:plug-in D:draw out (except MM frame) can be ignored in the previous picture N Breaking capacity : N...
Page 30 - MCM 409/639-Breakers for Complete Motor Protection
M ou ld ed C as e C irc ui t-b re ak er B B.17 Technology transfers reliable power MC 169/259-RCD Unit 3pole 4pole (1) Type Ir A Cat. No. Cat. No. MC169 220 / 440 DB3 / M91-2/6 DB4 / M91-2/6 400 / 690 DB3 / M91-4/6 DB4 / M91-4/6 MC259 220 / 440 DB3 / M92-2/6 DB4 / M92-2/6 400 / 690 DB3 / M92-4/6 DB4...
Page 35 - Curve; Time-current Curves for MM169 type
M ou ld ed C as e C irc uit -b re ak er B B.22 Technology transfers reliable power Curve Time-current Curves for MM169 type • Breaker MM169/L 16-32A L type Set at 0.8×ln Ir=12.5 or 16A set at 1×ln Ir =16 or 20A X rated current In Tr ip time Minutes Second s L type L type L type 7.2 L type L type L t...
Page 43 - Highest 3 level nominal current; level current limit: I; padLock to
M in ia tu re C irc uit B re ak er C C.1 Technology transfers reliable power MCB's series E90 ■ Excellent performance meets requirements of clients from different industries. ■ Highest 3 level nominal current ■ Human oriented design, safe and reliable Characteristics When short-circuit occurs, the m...
Page 45 - Accessory
M in ia tu re C irc uit B re ak er C C.3 Technology transfers reliable power Breaker Selection Guide Quick Selection Table 10kA DC MCB's E90S UC Pole width rated current [A] B C Pack Cat. No. Cat. No. 18mm 0.5 - E91S UC C0.5 12 1 - E91S UC C01 12 2 - E91S UC C02 12 3 - E91S UC C03 12 4 - E91S UC C04...
Page 47 - E90-B trip current limit curve; Ip's nominal current when operating voltage is 230/400V
M in ia tu re C irc uit B re ak er C C.5 Technology transfers reliable power E90-B trip current limit curve • E90-C trip nominal current curve • E90-D trip nominal current curve • Ip's nominal current when operating voltage is 230/400V Estimated short-circuit current Icc (kA) Ip's nominal current wh...
Page 48 - Hotline