Page 2 - Telecom applications
Telecom applications A complete range of battery solution for the multitude needs of the modern networks AEG Belgium customer day 20-6-2012 Telecom 2
Page 3 - Context
Context Multiplication of sites with the deployment of new Telecom generations and in new regions Cost and availability of Energy is always a constant concern In Asia Pacific, South America and Africa Deployment from urban population to rural Remote sites connected to the grid or not Frequent failur...
Page 4 - Our battery’s offer for Telecom
Our battery’s offer for Telecom Intensium 1 Power Plus 4000 48V – 4000W (*) SUNICA+ Tel.X SPH Intensium 3 Energy 48V – 2 300 Wh Evolion 48V – 4000 Wh AEG Belgium customer day 20-6-2012 Telecom Intensium Flex 4
Page 5 - Suitable for all applications; Distributive Power CO
5 Suitable for all applications AEG Belgium customer day 20-6-2012 Telecom Remote site (BTS, ANU) Distributive Power CO On Grid site (BTS) Off – Grid (BTS) R e li a b le G ri d N o n - R e li a b le o r N o G ri d
Page 6 - Benefits of the Saft’s ranges
Benefits of the Saft’s ranges High reliability Long life (~same as equipment) Temperature resistant 0 2 4 6 8 10 12 14 16 18 20 25 30 35 40 45 50 Average Temperature (deg C) L if e ti m e i n Y e a rs i n t h e f ie ld VRLANCX x x x x 2222 x 3.2 x 3.2 x 3.2 x 3.2 x 5.2 x 5.2 x 5.2 x 5.2 TLX: 14 year...
Page 7 - TCO Comparison for wireless site in Spain:
Cumulative Cost over Selected Analysis Period 0 2000 4000 6000 8000 10000 12000 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Year C u m u la ti v e C o s ts SAFT T LX Battery w/o ACVRLA with AC Currency € TCO Comparison for wireless site in Spain: Time Period 15 years Summary of Cost Analysis TLX VRLA Cumu...
Page 9 - Saft batteries for Telecom networks
Saft batteries for Telecom networks Saft Ni-Cd brings lower TCO (Total Cost of Ownership) and highest failsafe reliability in hostile environments Today, Saft Ni-Cd is the choice done for wireline & wireless networks in temperature controlled or non controlled sites Saft Li-ion offers maximum En...
Page 10 - TLX for more reliability
Page 12 - TLX benefits; Additional benefits with TLX
AEG Belgium customer day 20-6-2012 Telecom TLX benefits Additional benefits with TLX Lighter, easier to handle and install Utilizes OSP footprints more efficiently Increases installed capacity in the same volume Requires no maintenance Typical Benefits with Ni-Cd Long Life Highly Reliable (99.999 “f...
Page 13 - Introduction to Li-Ion battery system
Page 14 - Battery chemistry comparison table
Battery chemistry comparison table Valve-Regulated Tubular Gel Flooded (wet) Sodium Nickel Lithium-ion LA (VRLA) LA (OPzV) LA (OPzS) Nickel Chloride Li-Ion Operating Voltage (V) 54.4 - 42.0 53.0 to 56.0 56.0 - 42.0 tempCompVoltage and low voltage Disconnect required Specific energy (Wh/kg) 30 to 40 ...
Page 15 - Non-aqueous chemistry won’t “spill energy”
What is Li-ion?Sealed, non-aqueous, ‘rocking-chair’ chemistry On Charge , ions moving from positive to negative… …on Discharge , vice versa Non-aqueous chemistry won’t “spill energy” AEG Belgium customer day 20-6-2012 Telecom 15
Page 16 - Saft offers Li-ion Systems; Saft solution for Telecom; NCA Technology
16 Three design pillars are needed to build a safe and reliable Li-ion Battery system Saft offers Li-ion Systems NCA or LiNiCoAlO 2 Iron phosphate or LiFePO 4 Cobalt or LiCoO 2 LiMnO 2 High Energy High Power Very HighPower Ultra HighPower Architecture Electronics Software Mechanical Thermal User Req...
Page 18 - Environmentally friendly; Positive impact on the environment :
Environmentally friendly Positive impact on the environment : Energy consumption reduced Low carbon footprint Recyclability Lead Free 18 AEG Belgium customer day 20-6-2012 Telecom
Page 20 - New Li-ion battery plant at Jacksonville’s
New Li-ion battery plant at Jacksonville’s AEG Belgium customer day 20-6-2012 Telecom Evolion will be manufactured in Jacksonville (USA) New plant for mass production with room for further expansion Start of production Second Half of 2011 20
Page 21 - 8V – Li-Ion for Telecom; 003: First lab samples available
Lithium-ion in 48-V Telecom Applications AEG Belgium customer day 20-6-2012 Telecom 21 48V – Li-Ion for Telecom 2003: First lab samples available First mass-production rack mounted version launched 2005 2010: wide array of manufacturers and products 2011: Arrival of second generation for outdoor har...
Page 22 - Li-ion NCA key metric summary; Intensium
Li-ion NCA key metric summary Intensium 1P+ Intensium 3 Evolion Technology NCA Li-ion NCA Li-ion NCA Li-ion Used in Bridging power/UPS Cycling/hybrid/ standby Cycling/hybrid/ standby Wh/l 56 128 > 170 Wh/kg 41 96 > 130 Typical Backup > 3 min > 15 min > 2 hrs Max. Watts 4000/2000 3600 ...
Page 23 - Design Overview
Design Overview 260 404 216 30 Kg 77 Ah3,9 kWh1 820 W 3 hrs charging time <30kg RS485 communication bus AEG Belgium customer day 20-6-2012 Telecom 23
Page 24 - Specific Requirements
Specific Requirements 5- Packaging 3- Thermal Aspects 4- Safety Management 2- Water Tightness 1-Mechanical Rigidity AEG Belgium customer day 20-6-2012 Telecom 24 24
Page 25 - Front Panel
Front Panel AEG Belgium customer day 20-6-2012 Telecom 25
Page 26 - Connectors
Connectors Both RJ45 connectors are linked together and have the same pinout 26 Pin RJ45 1 RS485 A 2 RS485 B 3 GND_RS & Wakeup - 4 Wakeup + 5 NC 6 NC 7 Alarm - 8 Alarm + AEG Belgium customer day 20-6-2012 Telecom
Page 27 - Supervision software
Supervision software 27 AEG Belgium customer day 20-6-2012 Telecom
Page 28 - Compliant to Telecom standards
AEG Belgium customer day 20-6-2012 Telecom Compliant to Telecom standards SAFETY > Telcordia GR 3150 level III – IEC 60 950 – NEBS level 3 – UL 1642 ENVIRONMENT > GR 3108 class 3 – ETSI 300 019 – EC Marking EMC > GR 1089 NEBS level 3 – EN 300 386 TRANSPORT > UN 3480 28
Page 29 - Evolion’s Performances
Page 30 - High performance over a wide Temperature’s range: - 40°C to +75°C
Evolion: designed for the more severe Telecom environment High performance over a wide Temperature’s range: - 40°C to +75°C Compatible with the Telecom chargers: 42.0 V to 56.0 V Good storage capability: 12+ months AEG Belgium customer day 20-6-2012 Telecom 30
Page 31 - Evolion State of charge
31 AEG Belgium customer day 20-6-2012 Telecom Li-Ion cells: State of charge vs open circuit voltage 0 10 20 30 40 50 60 70 80 90 100 3 3.2 3.4 3.6 3.8 4 4.2 Open circuit voltage (V) S ta te o f c h a rg e ( % ) Measured SOC Linear approximation SOC = (V-3.3)/0.7 % Evolion State of charge
Page 32 - Evolion : discharge characteristics; Discharge curve from
Evolion : discharge characteristics AEG Belgium customer day 20-6-2012 Telecom • Discharge curve from Cn/2 to Cn/16 rate • Discharge curve at Cn/2 at different temperatures 32
Page 33 - Evolion : high cycling capability
Evolion : high cycling capability AEG Belgium customer day 20-6-2012 Telecom >4,300 cycles @ 80% DoD >8,200 cycles @ 50% DoD 33
Page 34 - More energy per weight and volume; High Calendar and cycle life; Fast charging capability; High charging efficiency
Evolion – Benefits Vs LACombining Expertise in Telecom and Li-ion More energy per weight and volume 2 times smaller and 4 times lighter than VRLA High Calendar and cycle life > Calendar: 20 years at +20°C & 10+ years at +40°C > Cycling: 4,300 cycles@80% DoD 3 to 5 times more than LA Fast c...
Page 35 - Lithium Battery Solution :; Cutting edge technology
Lithium Battery Solution : Cutting edge technology for high performance UPS
Page 38 - Modular System; Very high Power; Light Weight
Intensium® Flex SystemsFor high power UPS in tight space environments Modular System > From 110 V to 720 V > Medium Power & High Power Modules • Synerion 48M (48V – 42Ah) • Synerion 48P (48V – 28Ah) > Easy parallelism Very high Power > More than 800 W/l at module level > No need t...
Page 39 - Control Module
Intensium® Flex The architecture 11 modules Synerion 48 P in Series • Voltage Window : 462 – 616V 14 cells VL 30 P Balancing Cell voltage measurement Temperature measurement End of charge, end of discharge signals AEG Belgium customer day 20-6-2012 Telecom 39 Example # 1 • 528V nominal • Backup 150 ...
Page 41 - Terminals & mechanical integration; Electrical interfaces : top of cabinet; Mechanical interfaces :
Terminals & mechanical integration Electrical interfaces : top of cabinet > M10 Power connections (OUT+ and OUT-) > Plastic circular connector 24Vdc supply (optional) > Plastic circular connector 230Vac supply (optional for other equipment’ s such as fan) > RJ 45 for CAN bus and Alar...
Page 42 - Intensium Flex for 528 V / 150 kW 1 min back up; System A; Battery type; Battery kWh
Intensium Flex for 528 V / 150 kW 1 min back up AEG Belgium customer day 20-6-2012 Telecom 42 System A System B System C Battery type Tubular Gel VRLA Vented LA Lithium-ion Battery kWh 36 75 16 Footprint (m2) 1,7 3,5 0,3 Weight (kg) 2 620 3 800 250 Volume (m3) 4,8 5,7 0,55
Page 43 - Intensium® Flex System – Main benefits
Intensium® Flex System – Main benefits AEG Belgium customer day 20-6-2012 Telecom 43
Page 44 - Interest of Saft Intensium Flex System High Power; No need to oversize the battery; Foot-print very limited; Weight and Space very optimized; Long cycle life; The best candidate for the New-Gen Data Center
Interest of Saft Intensium Flex System High Power No need to oversize the battery 50% less kWh to be installed to meet the requirement Foot-print very limited Up to 80% of the surface saved Weight and Space very optimized Only 10 % space and weight of conventional solutions Long cycle life Less main...
Page 45 - Thank you