Manual ACM 9 - ARE i9 release Version: 05 Page: 2 / 45 Manual ACM9_ARE i9 release V05.docx 1. Introduction ................................................................................................................................................... 5 2. ACM 9 .....................................
Page 5 - Introduction; Typical system structure
Manual ACM 9 - ARE i9 release Version: 05 Page: 5 / 45 Manual ACM9_ARE i9 release V05.docx 1. Introduction ACM 9 Industrial Ethernet (EtherCAT®, EtherNet/IP™, Profinet®), AEG ID Communication Module, provides Industrial Ethernet connectivity for ARE i9, AEG ID RFID reader family. Both units are dedi...
Page 6 - Hardware
Manual ACM 9 - ARE i9 release Version: 05 Page: 6 / 45 Manual ACM9_ARE i9 release V05.docx 2. ACM 9 ACM 9 Industrial Ethernet communication module supports Industrial Ethernet connectivity. EtherCAT, EtherNet/IP and Profinet are implemented (only one at a time). ACM 9 has 2 Industrial Ethernet ports...
Page 7 - Connectivity
Manual ACM 9 - ARE i9 release Version: 05 Page: 7 / 45 Manual ACM9_ARE i9 release V05.docx 2.1.3 Connectivity Auxiliary Port (AUX) M12 socket 5 Pin male A-coded. Industrial Ethernet Port 1 Industrial Ethernet Port 2 Auxiliary Port Power + RS 232 4 digital Inputs 4 digital outputs Serial Port 1 ARE i...
Page 8 - Profinet
Manual ACM 9 - ARE i9 release Version: 05 Page: 8 / 45 Manual ACM9_ARE i9 release V05.docx Industrial Ethernet Port (Port 1, Port 2) M12 socket 4 Pin female D-coded (standard Industrial Ethernet) Serial Ports for ARE i9 (1-4) M12 socket 5 Pin female A-coded PIN 1 – +7V PIN 2 – GND PIN 3 – TX PIN 4 –...
Page 9 - Grounding
Manual ACM 9 - ARE i9 release Version: 05 Page: 9 / 45 Manual ACM9_ARE i9 release V05.docx Digital Inputs (input) M12 socket 8-Pin male A-coded Digital outputs (output) M12 socket 8-Pin female A-coded 2.1.4 Grounding PIN 1 – Input for serial port 1 PIN 2 – Input for serial port 2 PIN 3 – Input for s...
Page 10 - Firmware
Manual ACM 9 - ARE i9 release Version: 05 Page: 10 / 45 Manual ACM9_ARE i9 release V05.docx 2.2 Firmware ACM 9 uses 32 Byte cyclic input data and 32 Byte cyclic output data. 2.2.1 Industrial Ethernet description files Profinet: File ACM9_PNS_V1_1_0.xml contains Profinet description for ACM 9. EtherC...
Page 11 - ACM 9 error messages
Manual ACM 9 - ARE i9 release Version: 05 Page: 11 / 45 Manual ACM9_ARE i9 release V05.docx 2.2.4 ACM 9 error messages ACM 9 itself has the following error messages. Wrong channel number (Error code #65) A wrong channel number is set to the master output data. Valid channel numbers are from ‘1’ to ‘...
Page 12 - Error messages coming through from ARE i9
Manual ACM 9 - ARE i9 release Version: 05 Page: 12 / 45 Manual ACM9_ARE i9 release V05.docx ACM 9 sets master input data to: Hex: 23 00 15 23 36 37 0D 00 … ASCII: <NAK> ‘#’ ‘6’ ‘7’ <CR> Meaning Change counter Serial interface port Error Text End character 2.2.5 Error messages coming thro...
Page 13 - ARE i9
Manual ACM 9 - ARE i9 release Version: 05 Page: 13 / 45 Manual ACM9_ARE i9 release V05.docx 3. ARE i9 ARE i9 is a small industrial RFID reader that is available as a LF - SEMI Industry, LF and HF version. ARE i9 LF hdx - SEMI Industry works with LF hdx transponders. ARE i9 LF works with (all) low fr...
Page 15 - Transponder orientation relative to ARE i9
Manual ACM 9 - ARE i9 release Version: 05 Page: 15 / 45 Manual ACM9_ARE i9 release V05.docx 3.1.4 Transponder orientation relative to ARE i9 Disk parallel (recommended) Glass transponder perpendicular (recommended) Direction of travel The highest read range is achieved right above the center of ARE ...
Page 16 - Read range for SEMI application
Manual ACM 9 - ARE i9 release Version: 05 Page: 16 / 45 Manual ACM9_ARE i9 release V05.docx 3.1.5 Read range for SEMI application Glass transponder Texas Instruments RI-TRP-DR2B Glass transponder perpendicular (recommended) The highest read range is achieved right above the center of ARE i9 front si...
Page 17 - Read range for miscellaneous applications
Manual ACM 9 - ARE i9 release Version: 05 Page: 17 / 45 Manual ACM9_ARE i9 release V05.docx 3.1.6 Read range for miscellaneous applications Glass transponder and Disk transponder with different transponder chips (see table at the bottom) Disk transponder parallel (recommended) Glass transponder perp...
Page 18 - Firmware ARE i9 LF hdx - SEMI Industry
Manual ACM 9 - ARE i9 release Version: 05 Page: 18 / 45 Manual ACM9_ARE i9 release V05.docx 3.2 Firmware ARE i9 LF hdx - SEMI Industry ARE i9 LF hdx - SEMI Industry reads low frequency hdx transponders, typically in glass transponder format 4mmx34mm. 3.2.1 Instruction Set Communication with ARE i9 L...
Page 19 - GT; PARAMETER
Manual ACM 9 - ARE i9 release Version: 05 Page: 19 / 45 Manual ACM9_ARE i9 release V05.docx 3.2.4 GT GT – Get Tag GT is used to retrieve the transponder UID. Input format: GT<CR> Hex: 47 54 0D ASCII: ‘G’ ‘T’ <CR> Output (example): 1234567812345678 <CR> Hex: 31 32 33 ... ... 38 0D A...
Page 20 - NID; CID
Manual ACM 9 - ARE i9 release Version: 05 Page: 20 / 45 Manual ACM9_ARE i9 release V05.docx 3.2.6 NID NID – Double reading of UID to ensure consistency in EMV polluted environment. NID is used to double read a transponder UID to ensure consistency in an EMV polluted environment. The transponder UID ...
Page 21 - CN; RD
Manual ACM 9 - ARE i9 release Version: 05 Page: 21 / 45 Manual ACM9_ARE i9 release V05.docx 3.2.8 CN CN – Filter no read from being transmitted via interface. CN is used in those cases, where no read information ‘XXXXXXXXXXXXXXXX’ is not to appear on the interface. Only valid transponder UID will be...
Page 22 - LD
Manual ACM 9 - ARE i9 release Version: 05 Page: 22 / 45 Manual ACM9_ARE i9 release V05.docx 3.2.11 LD LD – lock memory page LD is used to lock a particular memory page from a transponder in the field. Input format: LD<SP> 1<CR> Hex: 4D 44 20 31 0D ASCII: ‘L’ ‘D’ <SP> ’1’ <CR>...
Page 23 - Error messages; Error code
Manual ACM 9 - ARE i9 release Version: 05 Page: 23 / 45 Manual ACM9_ARE i9 release V05.docx The following parameters are set: TOR 50 LRD 01001 MD 2 LNRD 10001 CID 0 LERR 10011 CN 0 LED 1 LSTB 01101 LRT 30 LGT 01111 LPA 00000 3.2.14 Error messages Error messages and protocol errors are acknowledged b...
Page 24 - Firmware ARE i9 LF
Manual ACM 9 - ARE i9 release Version: 05 Page: 24 / 45 Manual ACM9_ARE i9 release V05.docx 3.3 Firmware ARE i9 LF ARE i9 LF works with (all) low frequency transponders in ASK, PSK and FSK modulation. Please see chapter 3.3.13 for details on which transponder chips are implemented. Depending on the ...
Page 28 - VSAVE
Manual ACM 9 - ARE i9 release Version: 05 Page: 28 / 45 Manual ACM9_ARE i9 release V05.docx 3.3.11 VSAVE VSAVE – Save parameter permanently in ARE i9 flash memory VSAVE is used to save parameters permanently in flash memory of ARE i9 to be available after power on. Input format: VSAVE <CR> Hex...
Page 29 - ALGO
Manual ACM 9 - ARE i9 release Version: 05 Page: 29 / 45 Manual ACM9_ARE i9 release V05.docx 3.3.13 Error messages Error messages and protocol errors are acknowledged by ARE i9 using an error code. The format is described below: <NAK> '#' <error code> <CR> Example error #02 (wrong p...
Page 32 - Firmware ARE i9 HF
Manual ACM 9 - ARE i9 release Version: 05 Page: 32 / 45 Manual ACM9_ARE i9 release V05.docx 3.4 Firmware ARE i9 HF 3.4.1 Instruction Set Communication with ARE i9 is based on a simple ASCII text based protocol. The host sends text based telegrams to ARE i9 and receives text based telegrams back cont...
Page 36 - INIT
Manual ACM 9 - ARE i9 release Version: 05 Page: 36 / 45 Manual ACM9_ARE i9 release V05.docx 3.4.11 INIT INIT – Restore standard parameters. Command needs to be followed up by VSAVE in order to permanently store the parameters. Input format: INIT<CR> Hex: 49 4E 49 54 0D ASCII: ‘I’ ‘N’ ‘I’ ’T’ &...
Page 37 - LED instruction set
Manual ACM 9 - ARE i9 release Version: 05 Page: 37 / 45 Manual ACM9_ARE i9 release V05.docx 3.5 LED instruction set ARE i9 employs a multi-color LED to signal different modes. Basically below colors can be created: The user can choose any color apart from white. This color is reserved for setup help...
Page 39 - LED Transponder number successfully read (LRD)
Manual ACM 9 - ARE i9 release Version: 05 Page: 39 / 45 Manual ACM9_ARE i9 release V05.docx 3.5.3 LED Transponder number successfully read (LRD) Successful read color is green, no flash Input format: LRD<SP> 01001<CR> Hex: 4C 52 44 20 30 31 ... 31 0D ASCII: ‘L’ ‘R’ ‘D’ <SP> ‘0’ ‘1’...
Page 40 - LED Process active; Activating Process active; Deactivating Process active
Manual ACM 9 - ARE i9 release Version: 05 Page: 40 / 45 Manual ACM9_ARE i9 release V05.docx 3.5.6 LED Error (LERR) Error color is red , flashing Input format: LERR<SP> 10011<CR> Hex: 4C 45 52 52 20 31 ... 31 0D ASCII: ‘L’ ‘E’ ‘R’ ‘R’ <SP> ‘1’ ... ’1’ <CR> Output: 10011<CR&...
Page 41 - LED Process status; Successful Process; Not Successful Process
Manual ACM 9 - ARE i9 release Version: 05 Page: 41 / 45 Manual ACM9_ARE i9 release V05.docx 3.5.8 LED Process status LED Process status is used to indicate the status of a process, after it is performed. Successful Process LED color is green, not flashing Input format: LPS<SP> 01001<CR> ...
Page 43 - System implementation; Power supply
Manual ACM 9 - ARE i9 release Version: 05 Page: 43 / 45 Manual ACM9_ARE i9 release V05.docx 4. System implementation 4.1 Power supply SEMI industry uses hdx LF RFID technology. This particular method relies on field gaps, where the RFID field is switched off. In this gap the transponder answers with...
Page 44 - FCC Statement; Information to the user.; Release, Change Protocol
Manual ACM 9 - ARE i9 release Version: 05 Page: 44 / 45 Manual ACM9_ARE i9 release V05.docx 5. FCC Statement 5.1 ACM 9 Valid for ACM 9 – EtherCAT, ACM 9 – Profinet, ACM 9 – Ethernet/IP Federal Communications Commissions (FCC) Statement §15.21 You are cautioned that changes or modifications not expre...