Page 2 - TABLE OF CONTENTS
TABLE OF CONTENTS ADMIRAL 86038270 05/22/07 1 Data Log/Table of Contents .............. 1 Safety Instructions ............................ 2 Controls ............................................ 3-5 Operations ........................................ 6-11 Troubleshooting ...............................
Page 3 - SAFETY INSTRUCTIONS; IMPORTANT SAFETY INSTRUCTIONS; When using an electrical appliance, basic precaution; READ ALL INSTRUCTIONS BEFORE USING THIS MACHINE.; SAVE THESE INSTRUCTIONS
SAFETY INSTRUCTIONS ADMIRAL 86038270 05/22/07 2 IMPORTANT SAFETY INSTRUCTIONS When using an electrical appliance, basic precaution must always be followed, including the following: READ ALL INSTRUCTIONS BEFORE USING THIS MACHINE. This machine is for commercial use. To reduce the risk of fire, electr...
Page 4 - CONTROLS/COMPONENT LOCATIONS; Brush Motor Circuit Breaker.
CONTROLS/COMPONENT LOCATIONS ADMIRAL 86038270 05/22/07 3 1. Main Handle. Used to pull and maneuver machine. 2. Handle Adjustment. Used to adjust height of handle. 3. Electrical Cord. 4. Solution Switch. Turns on pump. Continuous position (bottom) activates electro-valve to dispense solution to floor...
Page 5 - Solution Accessory Tool Hookup.; Used; Brush Height Adjustment.; Used to; Front Lifting Handle.
CONTROLS/COMPONENT LOCATIONS ADMIRAL 86038270 05/22/07 4 1. Solution Accessory Tool Hookup. Used for various auxiliary cleaning tools. 2. Vacuum Hose Door. Used to connect various auxiliary 1 ½ inch cleaning tool vacuum hoses. 3. Brush Height Adjustment. Used to regulate brush height from storage po...
Page 6 - Solution Intake Cover.
CONTROLS/COMPONENT LOCATIONS ADMIRAL 86038270 05/22/07 5 1. Solution Intake Cover. 2. Vacuum Intake Cover. 3. Float Shut-Off. 4. Clean-Out Opening. 5. Pour Spout. 6. Lift Handle. 2 1 3 4 5 6 6
Page 7 - FILLING OPERATIONS; FILLING THE ADMIRAL; Add water
FILLING OPERATIONS ADMIRAL 86038270 05/22/07 6 FILLING THE ADMIRAL NOTE: Use clean bucket of water to fill solution tank Do not put defoamer, solvents, spotter or prespray chemicals in the solution tank . Do not allow water to spill into vacuum motor inlet. Dry spillage from top of solution tank bef...
Page 8 - OPERATIONS; Adjust brush to proper setting.; CORRECT; INCORRECT
OPERATIONS ADMIRAL 86038270 05/22/07 7 Remove electrical cord and literature from recovery tank. Fill solution tank (see filling instructions page 6). Adjust brush to proper setting. Note: For good operation the brush must skim the carpet. If circuit breaker trips raise brush to prevent damage to mo...
Page 9 - Lower machine to floor.
OPERATIONS ADMIRAL 86038270 05/22/07 8 Select continuous setting to start solution spray or select intermittent setting to enable use of trigger switches to start solution spray. The intermittent setting requires the operator to hold any one of the three trigger switches in the “on” position with th...
Page 10 - CLEANING PROCEDURE; shut down the; OFF
CLEANING PROCEDURE ADMIRAL 86038270 05/22/07 9 Release intermittent trigger switches or turn off continuous setting on solution switch approximately 1 foot before ending cleaning pass. Push down on handle to raise vacuum shoe and brush before moving to the next cleaning pass. Overlap brush contact a...
Page 11 - SOLUTION
CLEANING PROCEDURE ADMIRAL 86038270 05/22/07 10 To speed drying, use a Windblower ™ fan. Empty recovery tank by releasing dump hose. Use a hose with cold water to clean out the recovery tank. Also drain solution tank after each use. STEP 7 STEP 8 After cleaning, turn off all controls, return brush t...
Page 12 - ACCESSORY TOOL USAGE
ACCESSORY TOOL USAGE ADMIRAL 86038270 05/22/07 11 Turn on vacuum motor switch and set solution switch to intermittent position. Note: Be sure brush switch is in off position and brush is in storage position. Squeeze handle on accessory tool to begin cleaning. STEP 3 STEP 4 STEP 1 STEP 2 Use only one...
Page 13 - TROUBLESHOOTING CHART; PROBLEM CAUSE
TROUBLESHOOTING CHART ADMIRAL 86038270 05/22/07 12 PROBLEM CAUSE SOLUTION No Power, Nothing Runs 1. Is the cord plugged in. 2. Circuit breaker tripped in building. 3. Faulty switch. 4. Faulty power cord or pigtail. 1. Plug in cord. 2. Reset breaker 3. Call for service. 4. Call for service. Vacuum Mo...
Page 14 - THIS PAGE LEFT INTENTIONALLY BLANK
ADMIRAL 86038270 05/22/07 13 THIS PAGE LEFT INTENTIONALLY BLANK
Page 15 - WIRING DIAGRAM
WIRING DIAGRAM ADMIRAL 86038270 05/22/07 14 86268290 PRV NO. 88229 86268460 PRV NO. 88333 86268430PRV NO. 88323 86268370PRV NO. 88276 FILTER 86003650 PRV NO. 34362 86268430 PRV NO. 88323 86268430 - PRV NO. 88323 86238840 PRV NO. 41356 86238830 PRV NO. 41355 8626 890 0 PRV NO . 88 65 5 8626 672 0 PRV...
Page 16 - MAINTENANCE; PERIODIC MAINTENANCE; Check for and remove any lint or debris around vac
MAINTENANCE ADMIRAL 86038270 05/22/07 15 PERIODIC MAINTENANCE Twice a month, flush a white vinegar solution (One quart vinegar to two gallons of water) or anti-browning solution (mixed as directed) through the extractor. This will prevent build-up of alkaline residue in the system. If spray jets bec...
Page 17 - VACUUM MOTOR REPLACEMENT; Turn off all switches and unplug machine.
MAINTENANCE ADMIRAL 86038270 05/22/07 16 ! WARNING: ONLY QUALIFIED MAINTENANCE PERSONNEL ARE TO PERFORM THE FOLLOWING REPAIRS. VACUUM MOTOR REPLACEMENT 1. Turn off all switches and unplug machine. 2. Remove recovery tank. 3. Remove the (2) screws that fasten the solution tank to the frame, and tilt ...
Page 18 - SOLUTION PUMP REPLACEMENT; Turn off all switches and unplug the machine.; BELT REPLACEMENT
MAINTENANCE ADMIRAL 86038270 05/22/07 17 ! WARNING: SOLUTION PUMP REPLACEMENT 1. Turn off all switches and unplug the machine. 2. Remove recovery tank. 3. Remove the (2) screws that fasten the solution tank to the frame, and tilt tank back to expose the inside of the frame. 4. Remove solution hoses ...
Page 19 - TECHNICAL SPECIFICATIONS; POWER TYPE; ELECTRIC VACUUM MOTOR:; GENERAL DIMENSIONS/WEIGHT; quick change jets.
TECHNICAL SPECIFICATIONS ADMIRAL 86038270 05/22/07 18 POWER TYPE ELECTRICAL: 230-240 V, 7 A, 50 HZ ELECTRIC VACUUM MOTOR: (1) –3 stage, 1 hp, 99 cfm (2.80 cubic meters/min.) Waterlift –117” (297cm) BRUSH: (1) 15” (38.1 cm.) SOLUTION PUMP: 100 PSI, diaphragm style, internal bypass SOLUTION CAPACITY: ...