Page 2 - Related Publications; Soneplex Broadband System Operation and Maintenance Manual (V5); Admonishments; personal injury or property damage if the hazard is not avoided.; General Safety Precautions
ADCP-61-743 • Issue 3 • September 2004 Page 2 2004, ADC Telecommunications, Inc. Related Publications Listed below are related manuals and their publication numbers. Copies of these publications can be ordered by contacting the ADC Technical Assistance Center at 1-800-366-3891. Title ADCP Number S...
Page 3 - FCC Compliance Statement; The Soneplex Broadband system is compliant with UL 1459.; Standards; Carrier to Customer Installation: DS1 Metallic Interface, 1997
ADCP-61-743 • Issue 3 • September 2004 Page 3 © 2004, ADC Telecommunications, Inc. FCC Compliance Statement The Remote Test Access Unit has been certified to comply with the requirements for Class A computing devices per part 15 of the FCC regulations. Warning: This equipment generates, uses, and ca...
Page 4 - DESCRIPTION; The RTAU has the following features:
ADCP-61-743 • Issue 3 • September 2004 Page 4 2004, ADC Telecommunications, Inc. 1 DESCRIPTION The Remote Test Access Unit (RTAU) (Figure 1) provides maintenance functionality for monitoring and intrusive test access to the DS1 channels in the chassis between the DS3 MUX and the low speed distribu...
Page 6 - DS3 MUX Compatibility; There are two installation procedures:
ADCP-61-743 • Issue 3 • September 2004 Page 6 2004, ADC Telecommunications, Inc. 1.1 DS3 MUX Compatibility Refer to Table 1 for compatibility information for DS3 MUXs, test access units, and MPU/SCU software versions. Table 1. DS3 MUX, TAU/RTAU, and MPU/SCU Software Compatibility DS3 MUX TYPE TEST...
Page 7 - Initial Installation; Be careful when inserting the RTAU module into a new chassis.
ADCP-61-743 • Issue 3 • September 2004 Page 7 © 2004, ADC Telecommunications, Inc. 2.1 Initial Installation This installation procedure applies to the first time an IBBC shelf will be populated with a RTAU module. If the IBBC shelf has already been populated with a RTAU module, go to 2.2. Maintenanc...
Page 8 - Figure 2. RTAU Mounting Position in the Soneplex Broadband; Pins
ADCP-61-743 • Issue 3 • September 2004 Page 8 2004, ADC Telecommunications, Inc. 14185-A RTAU MODULE HSW HSP TAU APU SCU MXP MXW DS3 FAIL RESET LMPTST/APS LPBK ENABLE ONLINE STATUS APS LOCKOUT FORCE CR MJ MN APU ACO PWR HSKP RMT ALM LMPTST DISP RMT 1-3 1-1 2-1 2-3 3-1 3-3 4-1 4-3 5-1 5-3 6-1 6-3 7...
Page 9 - packing material. Inspect the module for damage
ADCP-61-743 • Issue 3 • September 2004 Page 9 © 2004, ADC Telecommunications, Inc. 2.2 Maintenance Installation (Existing System) Replacement of the RTAU module in existing IBBC shelves should follow normal maintenance procedures. Since a module has already been in service in the affected slot, the ...
Page 10 - CHECK; Figure 3. RTAU Front Panel
ADCP-61-743 • Issue 3 • September 2004 Page 10 2004, ADC Telecommunications, Inc. 3 LED CHECK 1. When the RTAU module (Figure 3) is seated, the STATUS LED will be lit red for approximately 5 seconds. All LEDs will then flash yellow, and then the STATUS LED will be lit green. If the STATUS LED is n...
Page 11 - FRONT PANEL OPERATION; Table 2. RTAU Front Panel Description; INDICATOR
ADCP-61-743 • Issue 3 • September 2004 Page 11 © 2004, ADC Telecommunications, Inc. 4 FRONT PANEL OPERATION All controls and indicators of the RTAU including the jack accesses for a selected DS1 signal are located on the front panel (Figure 3). The controls and indicators are described in Table 2. T...
Page 12 - CONFIGURATION
ADCP-61-743 • Issue 3 • September 2004 Page 12 2004, ADC Telecommunications, Inc. 5 CONFIGURATION Use this menu to view or edit the configuration for the RTAU module after it is installed in the chassis. This menu can also be used to equip, provision, assign thresholds, and assign service state. N...
Page 14 - Figure 4. System Maintenance Menu
ADCP-61-743 • Issue 3 • September 2004 Page 14 2004, ADC Telecommunications, Inc. SYSTEM MAINTENANCE 1. Force/APS Commands 2. Reset/LED Test Commands 3. Execute ACO (Alarm Cutoff) 4. Loopback Status/Commands 5. Display Inventory 6. Display Circuit IDs 7. SCU-860 Data Transfer Commands 8. Trouble I...
Page 15 - Assign the selections by pressing Enter or Return.; RTAU SETUP AND CONTROL; Figure 6. RTAU Setup and Control Screen; TEST ACCESS UNIT STATUS/COMMANDS; Figure 7. Test Access Unit Status/Commands Screen
ADCP-61-743 • Issue 3 • September 2004 Page 15 © 2004, ADC Telecommunications, Inc. 7. Assign the selections by pressing Enter or Return. RTAU SETUP AND CONTROL EQUIPMENT SETUP =============== Current User : NONE Test Circuit: 1-1 Line Code : INTERNAL Mode : DISABLE SIGNAL GENERATOR SETUP ==========...
Page 16 - Table 3. RTAU Configuration Fields
ADCP-61-743 • Issue 3 • September 2004 Page 16 2004, ADC Telecommunications, Inc. Table 3. RTAU Configuration Fields FIELD TYPE OPTIONS DESCRIPTION DEFAULT EQUIPMENT SETUP FIELDS Current User Toggle OVERVIEW: The Current User field can only be set to NONE or CRAFT from the Craft menu. If the Curre...
Page 17 - Table 3. RTAU Configuration Fields, continued
ADCP-61-743 • Issue 3 • September 2004 Page 17 © 2004, ADC Telecommunications, Inc. Table 3. RTAU Configuration Fields, continued FIELD TYPE OPTIONS DESCRIPTION DEFAULT EQUIPMENT SETUP FIELDS, continued Mode Toggle OVERVIEW: Valid access modes and the resulting configurations are shown in Figure 8 (...
Page 23 - FIELD
ADCP-61-743 • Issue 3 • September 2004 Page 23 © 2004, ADC Telecommunications, Inc. Table 3. RTAU Configuration Fields, continued FIELD TYPE OPTIONS DESCRIPTION DEFAULT Elapsed Time ES Display only None Six-digit counter or blank. Blank Elapsed Time EFS Display only None Six-digit counter or blank. ...
Page 24 - Figure 8. RTAU Test Configuration Block Diagram; MONF; Figure 9. MONF and MONE
ADCP-61-743 • Issue 3 • September 2004 Page 24 2004, ADC Telecommunications, Inc. DS3 MUX RTAU PATTERN GEN DETECTOR CONTROLLER A B MPU or SCU LINE CARD DS1 TEST SET RX TX BIPOLAR ACCESS RTAU FRONT PANEL DS3 EQUIPMENT MONITOR SPLIT DS1 FACILITY 11864-C Figure 8. RTAU Test Configuration Block Diagra...
Page 25 - SPLTA; Figure 10. SPLTB and SLPTA; Figure 11. Typical Round-Robin Test Configuration
ADCP-61-743 • Issue 3 • September 2004 Page 25 © 2004, ADC Telecommunications, Inc. DS3 MUX RTAU A B EQUIPMENT (E) [NETWORK] FACILITY (F) [CUSTOMER] CIRCUIT UNDER TEST TEST SIGNAL GENERATOR TEST SIGNAL GENERATOR DS3 MUX RTAU A B EQUIPMENT (E) [NETWORK] FACILITY (F) [CUSTOMER] CIRCUIT UNDER TEST 1186...
Page 26 - Figure 12. Typical End Test Configuration; SPLTF; Figure 13. SPLTF and SLPTE
ADCP-61-743 • Issue 3 • September 2004 Page 26 2004, ADC Telecommunications, Inc. A END INTEROFFICE FACILITY CPE INSERT: NETWORK DROP: NETWORK F E 11868-B Z END CPE SPLTE RTAU QRS B = "B" TRANSMISSION PATH = SIGNAL PRESENCE DETECTOR = TEST SIGNAL GENERATOR OR UNFRAMED (QRS) F = FACILITY (C...
Page 27 - Figure 15. SPLTFL and SPLTEL
ADCP-61-743 • Issue 3 • September 2004 Page 27 © 2004, ADC Telecommunications, Inc. SPLTF INSERT: NETWORK DROP: CUSTOMER INSERT: CUSTOMER F E QRS A END CPE RTAU INTEROFFICE FACILITY Z END CPE DROP: NETWORK INSERT: NETWORK INSERT: CUSTOMER F E 11870-B SPLTE QRS RTAU OFFICE A OFFICE Z B = "B" ...
Page 28 - LOOPE; Figure 16. LOOPF and LOOPE; Figure 17. RTAU Setup and Control Screen (Starting a Measurement); COMMANDS
ADCP-61-743 • Issue 3 • September 2004 Page 28 2004, ADC Telecommunications, Inc. DS3 MUX RTAU A B A B EQUIPMENT (E) [NETWORK] FACILITY (F) [CUSTOMER] CIRCUIT UNDER TEST SIGNAL PRESENCEDETECTOR DS3 MUX RTAU EQUIPMENT (E) [NETWORK] FACILITY (F) [CUSTOMER] CIRCUIT UNDER TEST SIGNAL PRESENCEDETECTOR ...
Page 29 - Table 4. TL1 Commands Used for the RTAU; COMMAND; SPECIFICATIONS; Table 5. RTAU Specifications; PARAMETER
ADCP-61-743 • Issue 3 • September 2004 Page 29 © 2004, ADC Telecommunications, Inc. Table 4. TL1 Commands Used for the RTAU COMMAND DESCRIPTION CHG-ACCMD-T1 Change Access Mode T1 CHG-LPBK-T1 Change Loopback T1 CHG-TSTSIG-T1 Change Test Signal T1 CONN-TACC-T1 Connect Test Access T1 DISC-MEAS Disconne...
Page 30 - CUSTOMER INFORMATION AND ASSISTANCE; Online Technical Support
ADCP-61-743 • Issue 3 • September 2004 Page 30 8 CUSTOMER INFORMATION AND ASSISTANCE ADC Technical support is available 24 hours a day, 7 days a week by contacting the ADC Technical Assistance Center. Sales Assistance 800.366.3891 • Quotation Proposals • Ordering and Delivery • General Product Infor...