- Page 2 – Setting Your Program Schedule; For installation by experienced service; Up to 2 Heat / 1 Cool Conventional; Displays the current room temperature
- Page 3 – Install your new Braeburn thermostat in 5 basic steps:; Install the Sub-Base; Installation; Disconnect power before beginning installation.; Thermostat Location
- Page 4 – Terminal Function Description; Connect Your Wires; Wiring Terminations; Provide Power; For 24 Volt AC power
- Page 5 – HEAT / 1 COOL Single or Dual Transformer; Typical Wiring Configurations; Conventional Systems; NOTES - Conventional Systems; Set System Type to; Heat Only or Millivolt; Set Installer Switch to
- Page 6 – NOTES - Heat Pump Systems; Set Installer Switches; Heat Pump Systems
- Page 7 – Attach Thermostat to Sub-Base; System Testing; Read Before Testing; The compressor delay can be bypassed by pressing the reset button
- Page 8 – Table of User Options; Detailed Explanation of User Options:; Temperature Differential; Setting User Options; Advanced User Options; RETURN; to advance to the
- Page 9 – Setting the Time and Day; Tips Before Setting Your Program Schedule; ARM; Setting; *Not available if User Option 1 is set to non-programmable
- Page 10 – Energy Saving Programs; Event; Day Programming; Weekday; Factory Settings
- Page 11 – SYSTEM
- Page 12 – Programming a 5-2 Day Schedule; PROG; Operating Your Thermostat; Setting the System Control Mode; COOL
- Page 13 – You will not see a program event indicator while in HOLD Mode.; Resetting the Thermostat
- Page 14 – Additional Operation Features; Compressor Protection; Thermostat Maintenance; Changing the Batteries; Remove thermostat body by gently pulling it from base.; Thermostat Cleaning
- Page 15 – Store this manual for future reference; Limited Warranty; YEAR
This thermostat requires 24 Volt AC Power or two (2) properly installed “AA”
Alkaline batteries for proper operation. When connecting 24 Volt AC Power
the batteries may be installed as a backup.
Thermostat installation and all
components of the system shall conform to Class II Circuits per NEC code.
For use only as described in this manual. Any other use
will void warranty.
2020NC
Single Stage Heat / Cool
Conventional and Heat Pump
1
Specifications
2
About Your Thermostat
3
Installation
4
System Testing
5
Setting User Options
6
Setting Your Program Schedule
7
Operating Your Thermostat
8
Additional Operation Features
9
Thermostat Maintenance
®
Warning
Turn off power to the heating or cooling
equipment before installation.
Attention
For installation by experienced service
technicians only.
2220NC
Up to 2 Heat / 1 Cool Conventional
Up to 2 Heat / 1 Cool Heat Pump
Read all instructions before proceeding.
This thermostat is compatible with:
• Single stage heat / cool conventional and heat pump systems
• Conventional systems up to 2 heat / 1 cool (2220NC only)
•
Single compressor heat pump systems with an auxiliary heat stage (2220NC)
• 250 – 750 millivolt heat only systems
Electrical and control specifications:
• Electrical Rating: 24 Volt AC
• 1 amp maximum load per terminal
• AC Power: 18 – 30 Volts AC
• DC Power: 3.0 Volt DC (2 “AA” Alkaline Batteries Included)
• Control Range: 45° – 90° F (7° – 32° C)
• Temperature Accuracy: +/- 1° F (+/- .5° C)
Terminations
• 2020NC – Rc, Rh, O, B, Y1, W1, G, C
• 2220NC – Rc, Rh, O, B, Y1, E/W1, G, W2, C
1
Specifications
2020NCW-100-05
Model number is located on back of thermostat
Programmable
Thermostats
Detailed
User Guide
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Was this manual helpful?
About this manual
- Brand
- Braeburn
- Model
- 2020
- Document type
- User Manual
- Category
- Thermostat
- Language(s)
- English
- Pages
- 15
- Format
Summary
1 Single Stage Heat / Cool Conventional and Heat Pump 6 Setting Your Program Schedule 7 Operating Your Thermostat 8 Additional Operation Features 9 Thermostat Maintenance For installation by experienced service technicians only. Up to 2 Heat / 1 Cool Conventional Up to 2 Heat / 1 Cool Heat Pump 2 Ab...
2 Install your new Braeburn thermostat in 5 basic steps: 1 Install the Sub-Base 2 Provide Power 3 Connect Your Wires 4 Set Installer Switches 5 Attach Thermostat to Sub-Base Install the Sub-Base: • Remove the sub-base from the body of the thermostat.• Mount the sub-base as shown below: 1 NOTE: After...
3 Terminal Function Description Rc Input 24 Volt AC Cooling Transformer (Dual Transformer Systems Only) Rh Input Power Connection (24 Volt AC Heating Transformer or Millivolt Power Source) O Output Reversing Valve (Cool Active) B Output Reversing Valve (Heat Active) Y1 Output Compressor Relay G Outp...