Page 2 - Wiring diagram
23 Wiring diagram A. Switch B. Blue wire C. Brown wire D. Terminal E. Ignition module FD Gas type NG HGC (MJ) Preinstalled NG In compliance with AS/NZ 3100 and AS 4551 Made in Spain Injectors marks 1,0 LHR 118 67 LHF 160 91 RHR 155 85 RHF 90 50 2,75 FD NG HGC (MJ) Preinstalled NG In compliance with ...
Page 3 - Content; Operating instructions.
3 Content Safety considerations . . . . . . . . . . . . . . . . 5 For your safety 5 What to do if you smell gas 5 Warnings 5 Installation . . . . . . . . . . . . . . . . . . . . . . . . . 7 Statutory requirements 7 Preparing to install . . . . . . . . . . . . . . . . . . . . . . . 7 Clearances . . ....
Page 5 - Safety considerations; For your safety
5 Safety considerations For your safety If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or death.Do not store articles on or against this appliance.Do not store flammable material near this appliance.Do not spray aero...
Page 7 - Installation; Statutory
7 Installation Statutory requirements This installation must conform with the following: Ø Manufacturer’s Installation instructions Ø Local Gas Fitting Regulations Ø Municipal Building Codes, Ø Refer to AS/NZS 5601.1 for Gas Installations. Ø S.A.A. Wiring Code Ø Local Electrical Regulations Ø Any ot...
Page 8 - Clearances
8 Before connecting the unit, check whether the local connection conditions (type of gas) are compatible with the unit’s setting. Observe any special conditions imposed by local suppliers (utilities). The specifications of this cooktop are stated on the data label located on the bottom of the cookto...
Page 10 - Connection; Electrical
10 Connection Electrical An electrical 10 amp socket needs to be within 1 m of the hotplate to allow electrical connection. The socket must remain accessible after installation of the appliance. Important note: This appliance is connected to the mains (240 VAC) by means of the connecting lead which ...
Page 12 - To change injectors; Changing the nozzles
12 Converting the cooktop from Nat. Gas to Universal LPG To change injectors All work involved in installation, setting and adaptation to a different gas type must be carried out by authorised personnel from our Service Centre and must comply with current regulations and the conditions laid down by ...
Page 15 - Operating instructions; Burner locations; Switching on
15 Operating instructions Burner locations The gas burners Operation There are indications to show which burner each control knob operates. Fig. 12. It is essential to ensure that all the burner parts and pan supports are correctly installed for the appliance to work correctly. Fig.13-14. Switching ...
Page 17 - Suitable pans
17 An orange-coloured flame is normal. This is caused by the presence of dust in the atmosphere, spilt liquids, etc.The kitchen will become hot and humid when this gas appliance is used. You must therefore ensure that the kitchen is well ventilated: either keep the natural ventilation apertures open...
Page 18 - Accessories; Additional wok pan
18 Accessories Depending on the model, the hob may include the following accessories. These are also available from the Technical Assistance Service. Additional wok pan support Wok pan Additional wok pan support: to be used exclusively on double and triple-flame burners with concave-based pans. Usin...
Page 20 - Precautions for use
20 Precautions for use The following advice is intended to help you save energy and prevent pan damage: Use pans which are the right size for each burner.Do not use small pans on large burners. The flame should not touch the sides of the pan. Do not use damaged pans, which do not sit evenly on the c...
Page 22 - Service
22 Service DO NOT MODIFY THIS APPLIANCE. Only authorized personnel from the Service Centre are qualified to work on the appliance. Sometimes certain faults detected can be easily resolved. Before calling the Service Centre, bear in mind the following advice: Any of the following are considered to be...