Page 2 - Content; Operating instructions.
3 Content Safety considerations . . . . . . . . . . . . . . . . 5 For your safety . . . . . . . . . . . . . . . . . . . . . . . 5 What to do if you smell gas . . . . . . . . . . . . . . 5 Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Installation . . . . . . . . . . . . . . . . . ...
Page 4 - Safety considerations; For your safety
5 Safety considerations For your safety If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or death.Do not store articles on or against this appliance.Do not store flammable material near this appliance.Do not spray aero...
Page 6 - Installation; Statutory
7 Installation Statutory requirements This installation must conform with the following: Ø Manufacturer’s Installation instructions Ø Local Gas Fitting Regulations Ø Municipal Building Codes, Ø Refer to AS/NZS 5601.1 for Gas Installations. Ø S.A.A. Wiring Code Ø Local Electrical Regulations Ø Any ot...
Page 7 - Clearances
8 Before connecting the unit, check whether the local connection conditions (type of gas) are compatible with the unit’s setting. Observe any special conditions imposed by local suppliers (utilities). The specifications of this cooktop are stated on the data label located on the bottom of the cookto...
Page 8 - Electrical
9 Installation of cooktop into the kitchen bench Installation procedure:Side clearances: If the distance measured from the periphery of the nearest burner to any vertical surface is less than 200 mm, the surface shall be protected in accordance with clauses 6.10.1.2 of AS/NZS 5601.1 1. For cutout di...
Page 9 - Gas
10 connected first and that all wires are connected to the correct terminals. Fig. 4. Gas During the planning stage, consider the position of supply connections. The cooktop must be connected to the gas supply with upstream connection of an isolation valve in accordance with the respectively valid r...
Page 10 - To change injectors
11 Ensure that the hose does not contact the hot surfaces of the hotplate, oven, dishwasher or any other appliance that may be installed underneath or next to the hotplate. The hose should not be subjected to abrasion, kinking or permanent deformation and should be able to be inspected along its ent...
Page 14 - Operating instructions; Burner locations; Switching on
15 Operating instructions Burner locations 2 1 4 3 6 5 4 1 Pan supports 2 Control knobs 3 Auxiliary burner (up to 1 kW) 4 Semi-rapid burner (up to 1,75 kW) 5 Rapid burner (up to 3 kW) 6 Triple-flame burner (up to 4 kW) The gas burners Operation There are indications to show which burner each contr...
Page 15 - Safety system; Switching off a burner; Warnings
16 While the control knob is still pressed down, sparks are produced on all burners. The flame ignites (it is no longer necessary to press down the control knob).2. Turn the control knob to the required setting.If it does not come on, turn the control knob to the off setting and repeat the steps abo...
Page 16 - Additional wok pan
17 kitchen is well ventilated: either keep the natural ventilation apertures open, or install a ventilation system (extractor hood).If using the appliance intensively for prolonged periods, you may require additional ventilation (e.g. by opening a window) or more effective ventilation (e.g. by incre...
Page 17 - Cooking
18 Additional coffee maker support Only for use on the auxiliary burner with pans which are no more than 12 cm in diameter. The manufacturer accepts no liability if these accessories are not used or are used incorrectly. Cooking recommendation Very high, high Medium Low Double or triple flame burner...
Page 18 - Precautions for use
19 Precautions for use The following advice is intended to help you save energy and prevent pan damage: Use pans which are the right size for each burner.Do not use small pans on large burners. The flame should not touch the sides of the pan. Do not use damaged pans, which do not sit evenly on the c...
Page 20 - Service
21 Service DO NOT MODIFY THIS APPLIANCE. Only authorized personnel from the Service Centre are qualified to work on the appliance. Sometimes certain faults detected can be easily resolved. Before calling the Service Centre, bear in mind the following advice: Fault Possible cause Solution The general...
Page 21 - Wiring diagram
22 Wiring diagram A. Switch B. Blue wire C. Brown wire D. Terminal E. Ignition module FD Gas type HGC (MJ) Preinstalled NG Injectors marks www.bosch-home.com CIF: A-28-893550 R OBERT BOSCH HAUSGERÄTE GMBH NG 1,0 MADE IN SPAIN Distributed by BSH Home Appliances Pty L...