I NSTALLATION I NSTRUCTIONS 2 Contents INTRODUCTION …………………………………………………………………………….….3 UNIT LOCATION ………………………………………………………………………………..6 UNIT INSTALLATION…………………………………………………………………………..7 UNIT INSTALLATION (SIDE DISCHARGE)………………………………………………..12 CHECK LIST…………………………………..………………………………………………..20 PROBLEM SOLV...
Page 3 - General Information; INJURY TO PERSONS, OBSERVE THE FOLLOWING:; WILL
I NSTALLATION I NSTRUCTIONS 3 1.0 Introduction General Information Thank you for purchasing a quality Bonaire Evaporative Cooler. W e care about your safety and would ask you to spend a few minutes reading these simple instructions before operating this product. Safety! Read carefully all of these i...
Page 4 - Evaporative Cooling
I NSTALLATION I NSTRUCTIONS 4 1.0 Introduction Evaporative Cooling The principal of your unit is to introduce fresh air, which is washed through the filter pads to provide cool fresh air. The air is exhausted taking with it any heat loading on the home. Exhaust It is essential for successful operati...
Page 5 - FAILURE TO COMPLY WITH THESE INSTRUCTIONS:; Packaging; Installed damaged products will not be covered by warranty.; Have you got all the system components?
I NSTALLATION I NSTRUCTIONS 5 1.0 Introduction FAILURE TO COMPLY WITH THESE INSTRUCTIONS: If this product is installed in a manner which is inconsistent with these installation instructions or, if the product has been modified and or altered from its original form, we shall not be held in any way li...
Page 6 - Unit Location Check List; Do not mount the unit on a section of roof that slopes towards a
I NSTALLATION I NSTRUCTIONS 6 2.0 Unit location T L N 2.1 Unit Location Check List EPA - A correctly installed unit will perform to specification on sound pressure radiated noise. As an installer, you have a professional obligation to ensure that every practical and reasonable effort is made to in...
Page 7 - Unit Installation; Down Discharge installation; “down; Down discharge configuration
I NSTALLATION I NSTRUCTIONS 7 Unit Installation 3.1 Down Discharge installation The evaporative cooler will be delivered with the fan motor assembly installed in “down discharge” mode. See the image below. The air will be directed downwards when installed in this configuration. NOTE: This cooler is ...
Page 8 - Electrical connections; Unscrew the thumb screws (transit screw) from the top of the grills.
I NSTALLATION I NSTRUCTIONS 8 Unit Installation 3.2 Electrical connections NOTE: Use hand tools when refitting the screws, tightening the screws with power tools can strip the screw holes. 3.2.1. Unscrew the thumb screws (transit screw) from the top of the grills. 3.2.2. Slide the removable grill up...
Page 9 - wiring harness to allow connection of the wiring.; Screw
I NSTALLATION I NSTRUCTIONS 9 Unit Installation 3.2.4. Remove the 3 screws from the control box to access the fan motor and pump wiring harness to allow connection of the wiring. 3.2.5. Connect the wiring as shown in the diagram below. The Listed flexible conduit electrical supply cable must protrud...
Page 10 - Water connections
I NSTALLATION I NSTRUCTIONS 10 Unit Installation 3.3 Water connections 3.3.1 Connect the Float valve to the water supply. Note the float valve and connections have been factory fitted requiring only water supply hose to be fitted to the external connection fitting at the corner of the tank /base as ...
Page 11 - Turn the water on to the unit and allow the unit to fill.
I NSTALLATION I NSTRUCTIONS 11 Unit Installation 3.3.2 Installation of the bleed off hose is required to prevent mineral deposits in the system. Adjust the bleed restrictor bracket to allow control of the bleed rate to suit local supply water conditions. Adjust the bleed off to approximately 2 ½ gal...
Page 12 - Converting from Down Discharge to; the venturi once removed.; Cap
I NSTALLATION I NSTRUCTIONS 12 Unit Installation 3.4 Converting from Down Discharge to Side Discharge Installation NOTE: Handle the fan/venturi assembly with care, as the fan blade is not protected by the venturi once removed. The evaporative cooler has been designed to allow for the discharge confi...
Page 13 - e. Disconnect the motor and pump cables from control box plugs.
I NSTALLATION I NSTRUCTIONS 13 Unit Installation e. Disconnect the motor and pump cables from control box plugs. f. Slide the lid out (be careful as the electrical box is attached to the underside of the lid) of the grill assemblies. Leave the side discharge panel in place. g. Remove the tape fasten...
Page 14 - j. With the retaining screws removed, lift the side discharge panel.
I NSTALLATION I NSTRUCTIONS 14 Unit Installation i. Remove and retain the 2 screws that fasten the side discharge panel. j. With the retaining screws removed, lift the side discharge panel. Remove screw Remove screw
Page 15 - venturi is at the top, aligned with the top of the panel.
I NSTALLATION I NSTRUCTIONS 15 Unit Installation k. Lay the side discharge panel down onto a surface that will not damage the panel. l. Present the fan motor assembly to the side panel ensuring the flat section of the venturi is at the top, aligned with the top of the panel. m. Carefully introduce t...
Page 16 - n. Ensure motor arms are securel
I NSTALLATION I NSTRUCTIONS 16 Unit Installation n. Ensure motor arms are securel y located by the “hooks” on the side panel motor arm supports (4 places). NOTE: Fan motor arms are on the “hook” side of the side panel motor arm support (4 places) as shown in the image below. o. Refit the side panel ...
Page 17 - Notches
I NSTALLATION I NSTRUCTIONS 17 Unit Installation p. Refit side discharge panel screws (2 places) to secure panel to base / tank. q. Fit the cap to the “down discharge” opening by aligning the 4 projections on cap with the 4 notches on the “down discharge” opening so the cap fits squarely in the base...
Page 19 - u. Reconnect the motor and pump cables to electrical box plugs.; Reconnect
I NSTALLATION I NSTRUCTIONS 19 Unit Installation u. Reconnect the motor and pump cables to electrical box plugs. v. Refer section 3.2.5 regarding wiring to electrical supply. WARNING: - Electrical connections should be performed by a qualified electrician so that all electrical wiring conforms to lo...
Page 20 - Checklist; Unit
I NSTALLATION I NSTRUCTIONS 20 Checklist Check List Use this list to check the installation. Unit □ All equipment ordered by the customer is installed. □ The unit is level and secure. □ The water supply line has been flushed to clear swarf and debris and is free of leaks. □ The tank is free ...
Page 21 - Problem Solving; PROBLEM
I NSTALLATION I NSTRUCTIONS 21 Problem Solving Problem Solving PROBLEM PROBABLE CAUSE REMEDY Unit fails to start a. Power Failure b. Tripped Circuit Breaker c. Blown Fuse d. Electrical Fault in cooler a. Wait for power to be turned on. b. Reset circuit breaker c. Replace d. Call Bonaire Care Line Fi...
Page 22 - Parts list; Replacement Parts List; Item Description
I NSTALLATION I NSTRUCTIONS 22 Parts list Replacement Parts List – 7000cfm Part # Item Description 0141480 THUMB SCREW SBB - SS 6080101PG TANK CP2 PIGEON GREY 6080102PG LID CP2 PIGEON GREY 6080108 WATER DISTRIBUTER SLOPE ASSEM 6080114 CAP SD/DD P GREY 425D 6080118 VENTURI 425mm 6080119 FAN 425mm 20D...
Page 23 - To Order Parts
I NSTALLATION I NSTRUCTIONS 23 Parts list To Order Parts www.bonairedurango.com THUMB SCREW
Page 24 - Maintenance; Check bleed off valve.; Winter Shutdown
I NSTALLATION I NSTRUCTIONS 24 Maintenance Spring Start-up Clean pump. Clean the pump once a year at start up. Check the pump spout for blockage. Ensure the impellor / shaft turn easily. If any hose connections have been removed during the pump cleaning process make sure that hoses and clamps are ...
Page 25 - Warranty
I NSTALLATION I NSTRUCTIONS 25 Warranty Statement on Product Warranty (U.S.A.) 1. Warranty Subject to the Conditions and Exclusions, Climate Technologies Pty Ltd provides the original purchaser with the following warranty: Climate Technologies Pty Ltd warrants this appliance for a (2) two year perio...
Page 26 - Climate Technologies Pty Ltd
I NSTALLATION I NSTRUCTIONS 26 Warranty j) If there is no certificate of compliance for plumbing or electrical work, Climate Technologies Pty Ltd reserves the right to refuse warranty on non-compliant installations. k) No responsibility will be accepted for outside elements such as pests, animals, p...
Page 27 - Service; For Technical Advice/Warranties
I NSTALLATION I NSTRUCTIONS 27 Service 6.0 Service Review A qualified service technician should conduct any service work carried out on this ducted Evaporative cooling product. It is important that periodical service is carried out on the product to ensure the customer receives the efficiency benefi...