Marine Electrical Products

e

-Series Single Circuit ON/OFF

Battery Switch with AFD*

PN 9004

e

Blue Sea Systems Inc.

Phone (360) 738-8230

425 Sequoia Drive

Fax (360) 734-4195

Bellingham, WA 98226 USA

E-mail [email protected]

www.bluesea.com

Features

• Disconnects single battery bank in emergencies, or when vessel is not in use

• For switching battery banks in applications requiring high power output,

reliability, and low heat generation

• Alternator Field Disconnect (AFD) protects the diodes in the alternator in the

event of the switch being switched to the OFF position while the engine is

running
Tin-plated copper studs:

• 3/8”-16 (M10) provide maximum conductivity and corrosion resistance

• One-piece to reduce risk of overheating

• 7/8” (22.22mm) length to accept multiple cable terminals

Case design:

• Allows surface mounting or rear panel mounting

• Accepts up to 4/0 AWG (95mm²) battery cables

Specifications

Inrush Rating: 2.5 sec.

1750 Amperes DC

Cranking Rating: 100 sec.

900 Amperes DC

Intermittent Rating: 5 min. (UL 1107) 600 Amperes DC

Continuous Rating: (UL 1107)

350 Amperes DC

Terminal Stud, Tin-Plated Copper

3/8”-16 (M10)

Torque

140 in-lb (15.82 N·m)

Cable Size to Meet Ratings**

4/0 AWG (95mm²)

Maximum Voltage Rating

48 Volts DC

Ignition Protected

marked

Agency Specifications

• Meets all American Boat and Yacht Council (ABYC) requirements for

battery switches

• UL Listed - UL 1107 for electric power switches

• Meets UL 1500 and SAE J1171 external ignition protection requirements

Guarantee

Any Blue Sea Systems product with which a customer is not satisfied may be

returned for a refund or replacement at any time.

For information about Blue Sea Systems Engine Starting Standard, go to

www.bluesea.com.

* Alternator Field Disconnect

** Reducing cable sizes will reduce current ratings

Caution

• Disconnect positive battery terminal before installing.

• Débranchez la cosse positive de la batterie avant de l’installer.

• Desconecte el terminal positivo de la batería antes de la instalación.

• Prima di eseguire l’installazione, disconnettere il terminale positivo della batteria.

• Consult marine electrical professional for proper wiring application.

• Consultez un professionnel de l’électricité marine pour installer le câblage correctement.

• Consulte a un electricista marino profesional para la aplicación de alambrado apropiada.

• Per assicurarsi che i cavi siano correttamente collegati, rivolgersi ad un elettricista specializzato in motori marini.

Installation

• Mount in an easily accessible location close to the batteries.

• Montez-le dans un endroit facilement accessible près des batteries.

• Monte en una ubicación fácilmente accesible cerca de la batería.

• Montare in un punto facilmente accessibile e vicino alle batterie.

• Attach one 4/0 AWG cable per terminal to meet ratings.

• Raccordez un câble 95mm² par cosse pour respecter les spécifications.

• Sujete un cable 95mm² por terminal de acuerdo a la clasificación.

• Attaccare un cavo 95mm² per conformarsi alle tarature.

• Refer to the latest edition of NFPA 302 and/or ABYC E11 Standard for installation information.

• Battery cable terminals must be attached under nut and lock washer. Torque 140 in-lb (15.82 N·m).

• Les cosses des câbles de batterie doivent être fixées sous la rondelle de sûreté et l’écrou – couple de serrage de 15,82 N·m (140 lb-po).

• Los terminales de los cables de batería deberán ser sujetados debajo de la tuerca y la arandela. Apriételos a una torsión de 15,82 N·m (140 lbs-pul).

• I terminali del cavo della batteria vanno attaccati con un dado e una rondella elastica: coppia di 15,82 N·m (140 lbs-in).

• AFD: Cut the field wire from the alternator to the voltage regulator; connect one end to F1, and the other end to F2.

• AFD: Coupez le fil allant de l’alternateur au régulateur de tension ; connectez-en une extrémité à F1 et l’autre à F2.

• AFD: Corte el cable de campo del alternador al regulador de voltaje, conecte un extremo al punto F1 y el otro extremo al punto F2.

• AFD: Staccare il cavo che unisce l’alternatore al regolatore di tensione; connettere un polo a F1 e l’altro a F2.

Operation

• Turn all appliances off before turning the battery switch to OFF.

• Éteignez tous les appareils électriques avant de mettre l’interrupteur de batterie sur ARRÊT.

• Apague todos los artefactos antes de girar el interruptor de batería a APAGADO (OFF).

• Spegnere tutte le apparecchiature prima di muovere l’interruttore della batteria su OFF (spento).

• Do not switch to OFF while engine is running.

• Ne le mettez pas sur ARRÊT alors que le moteur tourne.

• No coloque el interruptor en APAGADO (OFF) mientras que el motor esté funcionando.

• Non muovere l’interruttore su OFF (spento) quando il motore è in moto.