Page 2 - © 2019 by Blink Network, LLC; . The contents of this document have been verified by the; Notice
Charge on. Page 2 of 37 Blink IQ 200 Level 2 AC EVSE Instruction Manual 10/9/2019 © 2019 by Blink Network, LLC No part of the contents of this document may be reproduced or transmitted in any form or by any means without the express written permission of Blink Network, LLC . The contents of this doc...
Page 4 - IMPORTANT SAFETY INSTRUCTIONS; Before installing or using the
Charge on. Page 4 of 37 Blink IQ 200 Level 2 AC EVSE Instruction Manual 10/9/2019 1. IMPORTANT SAFETY INSTRUCTIONS Before installing or using the Blink Network, LLC (Blink) electric vehicle supply equipment (EVSE), read all these instructions, paying particular attention to any WARNING and CAUTION m...
Page 5 - SAVE THESE INSTRUCTIONS
Charge on. Page 5 of 37 Blink IQ 200 Level 2 AC EVSE Instruction Manual 10/9/2019 FCC Rules and Industry Canada License-Exempt RSS Standard(s) • This device complies with Part 15 of the FCC Rules. Changes or modifications are not expressly approved • English: This device complies with Industry Canad...
Page 6 - MODEL NUMBER
Charge on. Page 6 of 37 Blink IQ 200 Level 2 AC EVSE Instruction Manual 10/9/2019 2. INTRODUCTION This Instruction Manual describes how to properly install the Blink IQ 200 Level 2 AC EVSE (Blink Product). Contact the Blink Support Center at 1-888-998-BLINK (2546) for troubleshooting assistance and ...
Page 7 - PRODUCT SPECIFICATIONS
Charge on. Page 7 of 37 Blink IQ 200 Level 2 AC EVSE Instruction Manual 10/9/2019 4. PRODUCT SPECIFICATIONS BLINK IQ 200 PRODUCTS POWER SPECIFICATIONS ADVANCED CHARGING STATION SMART CHARGING STATION KIOSK Input/Output Power (Max.) 19.2kW Max. 19.2W Max. Input Only Input/Output Power (Standby) <1...
Page 8 - PRE-INSTALLATION INSTRUCTIONS; Safety and Grounding
Charge on. Page 8 of 37 Blink IQ 200 Level 2 AC EVSE Instruction Manual 10/9/2019 5. PRE-INSTALLATION INSTRUCTIONS 5.1. Safety and Grounding 5.1.1. Safety Check CAUTION: DISCONNECT ELECTRICAL POWER PRIOR TO INSTALLING THE BLINK CHARGING STATION. FAILURE TO DO SO MAY CAUSE PHYSICAL INJURY OR DAMAGE T...
Page 9 - Conduit & Breaker Size Guide; All Specifications are Per Charging Station or Port; Table 1 Conduit and Breaker Size Guide; CAUTION; MUST; Station
Charge on. Page 9 of 37 Blink IQ 200 Level 2 AC EVSE Instruction Manual 10/9/2019 5.2. Conduit & Breaker Size Guide All Specifications are Per Charging Station or Port Max. Output (Charging) Current Typical Circuit Breaker (CB) 3 Typical Wire Specs 3 Typical Conduit Size 3 Blink IQ 200 Enclosure...
Page 10 - Mounting Options; Figure 1 Mounting Options; Product Placement Tips
Charge on. Page 10 of 37 Blink IQ 200 Level 2 AC EVSE Instruction Manual 10/9/2019 5.3. Mounting Options Figure 1 Mounting Options 5.4. Product Placement Tips 5.4.1. Kiosk and Smart Unit Placement • Kiosk units should be installed within 150ft. (line-of-sight) of the farthest Smart unit. • Walls, pi...
Page 11 - INSTALLATION INSTRUCTIONS; Tools Required for Installation; Table 2 Tools Required for Installation; Parts Required for Installation; Wall Mount Only; Table 3 Parts Required for Installation
Charge on. Page 11 of 37 Blink IQ 200 Level 2 AC EVSE Instruction Manual 10/9/2019 6. INSTALLATION INSTRUCTIONS 6.1. Tools Required for Installation Tool Applicable Models Supplier Name Supplier Part # Security Torx T20 L-Driver All Product Models Blink Included in Product Box Security Torx T20 Driv...
Page 12 - Installation Procedure; Open the Blink Product box and locate the mounting bracket.; Figure 2 Mounting Bracket; Drill holes in the wall or mounting surface for the mounting bolts.
Charge on. Page 12 of 37 Blink IQ 200 Level 2 AC EVSE Instruction Manual 10/9/2019 6.3. Installation Procedure 6.3.1. Open the Blink Product box and locate the mounting bracket. Figure 2 Mounting Bracket 6.3.2. Drill holes in the wall or mounting surface for the mounting bolts. Note: A recommended m...
Page 13 - Figure 3 Top Cover Screws; Remove the appropriate; Figure 4; Choose the appropriate conduit and wire based on; Table 1 Conduit and; and in accordance with all applicable state, local, and national
Charge on. Page 13 of 37 Blink IQ 200 Level 2 AC EVSE Instruction Manual 10/9/2019 6.3.4. Remove the top cover from the Blink Product using a Security T20 driver to loosen the 7 screws. Figure 3 Top Cover Screws 6.3.5. Remove the appropriate cover ( A or B ) based on the desired conduit entry point....
Page 14 - Figure 5 Product Installation; , crimp the included ring terminals to the wires.
Charge on. Page 14 of 37 Blink IQ 200 Level 2 AC EVSE Instruction Manual 10/9/2019 6.3.7. Attach the product to the mounting bracket using the 4 included mounting bolts and a Security T20 Driver using a torque force of 13 Inch-Pounds (1.5 Newton Meters). CAUTION Do not overtighten the mounting bolts...
Page 15 - Remove the clear plastic cover from the terminal block.; Figure 6 Terminal Block; Advanced and Smart Models; Re-attach the clear plastic cover to the terminal block.
Charge on. Page 15 of 37 Blink IQ 200 Level 2 AC EVSE Instruction Manual 10/9/2019 6.3.10. Remove the clear plastic cover from the terminal block. 6.3.11. Attach the crimped ring terminals to the terminal block inside the Blink Product. Figure 6 Terminal Block 6.3.12. Ensure that the terminal block ...
Page 16 - Figure 7 Power Switch; Figure 8 Top Cover Screws
Charge on. Page 16 of 37 Blink IQ 200 Level 2 AC EVSE Instruction Manual 10/9/2019 6.3.14. Figure 7 Power Switch 6.3.15. Re-attach the top cover to the Blink Product using a Security T20 Driver and a torque force of 13 Inch-Pounds (1.5 Newton Meters). CAUTION Do not overtighten the mounting bolts as...
Page 17 - Figure 9 Advanced, Smart, and Kiosk Units
Charge on. Page 17 of 37 Blink IQ 200 Level 2 AC EVSE Instruction Manual 10/9/2019 6.3.16. Apply power to the Blink Product. 6.3.17. If applicable, coil the charge cable around the Blink Product and attach the charging connector to the holster. Figure 9 Advanced, Smart, and Kiosk Units
Page 18 - SETUP INSTRUCTIONS; Web Portal Access; Figure 10 Web Portal: IP Address; User Name
Charge on. Page 18 of 37 Blink IQ 200 Level 2 AC EVSE Instruction Manual 10/9/2019 7. SETUP INSTRUCTIONS 7.1. Web Portal Access 7.1.1. Contact the Blink Network Support Center at 1-888-998-BLINK (2546) to obtain the Wi-Fi password AND the Web Portal password . 7.1.2. Using a computer, a tablet, or a...
Page 19 - Figure 11 Station Settings; Station Settings; Figure 12 Maximum Charging Current (Max Amperage FW Setting); Circuit Breaker Size; Table 4 Maximum Charging Current (Max Amperage FW Setting)
Charge on. Page 19 of 37 Blink IQ 200 Level 2 AC EVSE Instruction Manual 10/9/2019 7.2. Changing the Maximum Output (Charging) Current of a Charging Station IMPORTANT: The maximum output (charging) current of the Blink Product must only be adjusted by authorized personnel. The maximum output (chargi...
Page 20 - Figure 13 Smart Unit Communication Settings Tab; Communication Settings; Figure 14 Smart Unit Gateway Serial Number; Apply
Charge on. Page 20 of 37 Blink IQ 200 Level 2 AC EVSE Instruction Manual 10/9/2019 7.3. Connecting a Smart Unit to a Kiosk (Smart Units Only) 7.3.1. On the Configuration page of the Smart Unit, select the Communication Settings tab. Figure 13 Smart Unit Communication Settings Tab 7.3.2. On the Commu...
Page 21 - OPERATING INSTRUCTIONS; Starting a Charge Session; Touch the Main Screen to begin the authorization process.; Figure 15 Main Screen; Enter the Unit # of the charging station then touch; ENTER; Figure 16 Blink Unit Selection Screen
Charge on. Page 21 of 37 Blink IQ 200 Level 2 AC EVSE Instruction Manual 10/9/2019 8. OPERATING INSTRUCTIONS 8.1. Starting a Charge Session 8.1.1. Release the charging connector from the holster and connect it to the EV. 8.1.2. Touch the Main Screen to begin the authorization process. Figure 15 Main...
Page 22 - Figure 17 Authorizing Screen; Once the Charge Confirmation screen appears, select the; Charge; button. If a selection is; Figure 18 Charge Confirmation Screen
Charge on. Page 22 of 37 Blink IQ 200 Level 2 AC EVSE Instruction Manual 10/9/2019 8.1.4. Initiate a charge session using one of the following authorization methods: • RFID Card • Remote Start Command (Using a Mobile App) • Blink Code (If Applicable) • Smart Credit Card / Apple Pay / Google Pay (May...
Page 24 - Stopping a Charge Session; Figure 21 Cost Summary Screen; Touch the; CLOSE; Figure 22 Session Ended Screen
Charge on. Page 24 of 37 Blink IQ 200 Level 2 AC EVSE Instruction Manual 10/9/2019 8.2. Stopping a Charge Session 8.2.1. Disconnect the charging connector from the EV at any time to stop the charge session. 8.2.2. Once the session has been stopped, the Cost Summary screen will appear (if applicable)...
Page 25 - Status Indicator; Description; Table 5 Status Indicator
Charge on. Page 25 of 37 Blink IQ 200 Level 2 AC EVSE Instruction Manual 10/9/2019 8.3. Status Indicator Status Indicator Description Definition Not Illuminated Power is OFF Flashing Yellow Device is Not Ready (i.e. Booting, Upgrading Firmware, etc.) Steady Yellow Device is Unavailable (i.e. Out of ...
Page 26 - CONFIGURATION; Factory Settings; tab will appear, which reflects the items which have been; Figure 23 Web Portal: Factory Settings; The following table provides an overview of each item.; Configuration Item
Charge on. Page 26 of 37 Blink IQ 200 Level 2 AC EVSE Instruction Manual 10/9/2019 9. CONFIGURATION 9.1. Factory Settings 9.1.1. Initially, the Factory Settings tab will appear, which reflects the items which have been configured at the factory. Figure 23 Web Portal: Factory Settings 9.1.2. The foll...
Page 27 - Station Settings
Charge on. Page 27 of 37 Blink IQ 200 Level 2 AC EVSE Instruction Manual 10/9/2019 9.2. Station Settings Configuration Item Description Default Hours of Operation Settings Default Hours of Operation Settings The default Hours of Operation. Settings sent from the Central System will supersede these d...
Page 28 - GPS Information; OCPP Settings
Charge on. Page 28 of 37 Blink IQ 200 Level 2 AC EVSE Instruction Manual 10/9/2019 GPS Information Latitude The latitude of the Blink Product. Longitude The longitude of the Blink Product. 9.3. OCPP Settings Configuration Item Description Remote Service Settings Remote Service Type Specifies the pro...
Page 29 - Communication Settings
Charge on. Page 29 of 37 Blink IQ 200 Level 2 AC EVSE Instruction Manual 10/9/2019 OCPP1.6 Settings OCPP1.6 Settings Settings based on the OCPP1.6 specification. 9.4. Communication Settings Configuration Item Description Network Mode The network mode that the Blink Product will use to communicate wi...
Page 31 - Maintenance Settings; Figure 24 Web Portal: Maintenance
Charge on. Page 31 of 37 Blink IQ 200 Level 2 AC EVSE Instruction Manual 10/9/2019 9.5. Maintenance Settings 9.5.1. The Maintenance settings can be accessed by selecting the Maintenance link on the left pane. Figure 24 Web Portal: Maintenance 9.5.2. Soft Reboot Reboot button. 9.5.3. Reset Factory De...
Page 32 - link on the; Figure 25 Web Portal: LLM Status; Security Settings; The security settings of a unit can be accessed by selecting the; Security; link on the left pane.; Figure 26 Web Portal: Security Settings; OQC Test Functionality
Charge on. Page 32 of 37 Blink IQ 200 Level 2 AC EVSE Instruction Manual 10/9/2019 9.6. Local Load Management Status (LLM Status) The local load management status of a unit can be accessed by selecting the LLM Status link on the left pane. Figure 25 Web Portal: LLM Status 9.7. Security Settings The ...
Page 33 - TROUBLESHOOTING; Troubleshooting Table; Situation
Charge on. Page 33 of 37 Blink IQ 200 Level 2 AC EVSE Instruction Manual 10/9/2019 10. TROUBLESHOOTING 10.1. Troubleshooting Table Situation Screen Displayed Action Out of Service: Station Disabled 1. The unit has been disabled and is out of service. 2. Call 1-888-998-BLINK (2546) for assistance. Ou...
Page 34 - Try a different unit.
Charge on. Page 34 of 37 Blink IQ 200 Level 2 AC EVSE Instruction Manual 10/9/2019 Payment Card Declined 1. There is an issue with the card or account (See Table 7 Reference Codes). 2. Call 1-888-998-BLINK (2546) for assistance. Blink Code is not Valid 1. There is an issue with the card or account. ...
Page 35 - Automatic Restart Functionality; setting is; On; ) with a delay ranging from 120
Charge on. Page 35 of 37 Blink IQ 200 Level 2 AC EVSE Instruction Manual 10/9/2019 Fault with Automatic Reset 1. A fault occurred (See Table 6 Error Codes). 2. Record the Error Code. 3. Wait 15 minutes for the system to recover from the fault or touch the RESET button to manually reset the system. 4...
Page 36 - Error Codes; Table 6 Error Codes; Reference Codes; Error Code Error Name; Table 7 Reference Codes
Charge on. Page 36 of 37 Blink IQ 200 Level 2 AC EVSE Instruction Manual 10/9/2019 10.4. Error Codes Error Code Error Name Error Description 1000 NoError No error to report. 1001 GroundFailure Ground fault circuit interrupter has been activated. Same as CCID protection. 1002 MissingGroundFailure Fai...