Table of Contents:

  • Page 3 – Air outlet
  • Page 4 – SPECIFICATION; NOTE
  • Page 5 – Test condition; OPERATING RANGE
  • Page 6 – OUTLINES AND DIMENSIONS; REQUIRED SPACE
  • Page 7 – WIRING DIAGRAM
  • Page 8 – REFRIGERANT SYSTEM DIAGRAM; Service; MAX. REFRIGERANT PIPING LENGTH and MAX. HEIGHT DIFFERENCE
  • Page 9 – DATA
  • Page 10 – Heating
  • Page 14 – -5. CAPACITY AND INPUT CORRECTION BY INVERTER OUTPUT FREQUENCY
  • Page 15 – ACTUATOR CONTROL; The fan motor turns ON/OFF, interlocking with the compressor.; -3. RELATION BETWEEN MAIN SENSOR AND ACTUATOR
  • Page 16 – SERVICE FUNCTIONS; JS; TROUBLESHOOTING; components for bursting and discoloration.
  • Page 17 – Outline of the function
  • Page 18 – Operational procedure
  • Page 23 – fl; B Check of open phase
  • Page 25 – G Check of outdoor thermistors; Unit operates COOL mode even if it is set to HEAT mode.
  • Page 26 – I Check of outdoor fan motor; Outdoor fan motor does not operate.; J Check of power supply; Inverter does not operate.
  • Page 30 – N Electromagnetic noise enters into TV sets or radios
  • Page 32 – Removing the cabinet; DISASSEMBLY INSTRUCTIONS; (1) Slide the sleeve and check if there is a locking lever or not.; Photo 1
  • Page 33 – (2) Disconnect the lead wire to the reactor and the following; Removing the discharge temperature thermistor,; Discharge temperature thermistor; Photo 3; Heat sink
  • Page 34 – Removing outdoor fan motor
  • Page 36 – Copyright 2008 MITSUBISHI ELECTRIC ENGINEERING CO.,LTD; TM
Loading the manual

SERVICE MANUAL

CONTENTS

1. TECHNICAL CHANGES ··································· 3
2. PART NAMES AND FUNCTIONS ····················· 3
3. SPECIFICATION ················································ 4
4. OUTLINES AND DIMENSIONS ························ 6
5. WIRING DIAGRAM ············································ 7
6. REFRIGERANT SYSTEM DIAGRAM ··············· 8
7. DATA ·································································· 9
8. ACTUATOR CONTROL ··································· 15

9. SERVICE FUNCTIONS ··································· 16
10. TROUBLESHOOTING ····································· 16
11. DISASSEMBLY INSTRUCTIONS ···················· 32

Wireless type
Models

MUZ-FD09NA

MUZ-FD09NA-

U1

MUZ-FD12NA

MUZ-FD12NA-

U1

OUTDOOR UNIT

Indoor unit service manual

MSZ-FD•NA Series (OBH497)

NOTE:

RoHS compliant products have <G> mark on the spec name plate.

TM

HFC

utilized

R410A

No. OBH498

PARTS CATALOG (OBB498)

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 3 - Air outlet

33 1 TECHNICAL CHANGES MUZ-FD09NA MUZ-FD12NA MUZ-FD09NA - U1 1. New model PART NAMES AND FUNCTIONS 2 MUZ-FD09NA MUZ-FD12NA MUZ-FD12NA - U1 Air outlet Drain outlet Piping Drain hose Air inlet

Page 4 - SPECIFICATION; NOTE

44 3 SPECIFICATION Outdoor unit model MUZ-FD09NA MUZ-FD12NA Capacity Rated (Minimum~Maximum) Cooling 1 Btu/h 9,000 (2,800~9,000) 12,000 (2,800~12,000) Heating 47 1 Btu/h 10,900 (3,000~18,000) 13,600 (3,000~21,000) Capacity Rated Heating 17 2 Btu/h 7,700 8,300 Power consumption Rated (Minimum~Maximum...

Page 5 - Test condition; OPERATING RANGE

55 Test condition ARI Mode Test Indoor air condition Outdoor air condition Dry bulb (°F) Wet bulb (°F) Dry bulb (°F) Wet bulb (°F) SEER (Cooling) "A" Cooling Steady State at rated compressor Speed 80 67 95 (75) "B-2" Cooling Steady State at rated compressor Speed 80 67 82 (65) "B...

Other Black & Decker Models

All Black & Decker Other