Quick installation guide for LB9217A and LB9218A
This installation guide gives step-by-step instructions on how to install LB9217A & LB9218A that pertains to this
17-port modular Ethernet switch.
Selecting a module combination with LB9217A and LB9218A
LB9217A can be plugged in with the combination of different copper and fiber optic connectors.
Following is a list of various modules pertains to this 17-port modulated Ethernet switch.
Figure 1: Front Panel of the Chassis, LB9217A.
Follow These Steps for Installation:
Step 1
: Turn off the power before installation.
Step 2
: Unscrew the cover plates of the module slots. Retain both the screws and the cover plates. The plates can be
reinstalled if the module is removed.
Step 3
: Remove the module from the static-free container then slowly slide the plug-In module into the designated slot,
following the plastic guides.
Step 4
: Snap in the Plug-In Module to attain a firm connection.
Step 5
: Tighten the screws retained from original cover plate.
Step 8
: Restore power.
_____________________________________________________________________
Figure 2: Removal of cover plate
Fiber module being installed
Select a proper site for LB9217A, Connect AC power cord to the receptacle on LB9217A & standard AC
outlet. Turn the switch on then to connect network with proper CAT 5 or fiber cable.
Figure 3:
Internal power:
Connect the supplied AC power cord to the receptacle on the back of the switch, and then plug it into a
standard AC outlet with a voltage range from 100 to 240 Vac.
Modules: Ports
LB9213A: 8TX
LB9219A: 4TX + 4FX (SC)
LB9216A: 6TX + 2FX (ST)
LB9218A: 6TX + 2FX (SC)
LB9214A: 8FX (ST)
LB9215A: 8FX (SC)
LB9007C-ST-R2: 1FX (ST)
LB9017C-SC-R2 (SC)
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.