Bard W36A1 - Manual
Bard W36A1 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – Contents
- Page 3 – GETTING OTHER INFORMATION AND PUBLICATIONS
- Page 4 – WALL MOUNT GENERAL INFORMATION; AIR CONDITIONER WALL MOUNT MODEL NOMENCLATURE; SHIPPING DAMAGE
- Page 5 – DUCT WORK; Refer to Maximum ESP of operation Electric Heat Table 6.; NOTE: If no return air duct is used, applicable installation; FILTERS; FIGURE 1
- Page 6 – INSTALLATION INSTRUCTIONS; WARNING; WALL MOUNTING INFORMATION
- Page 7 – FIGURE 2
- Page 11 – minimum
- Page 14 – WIRING – MAIN POWER; must be; WIRING – LOW VOLTAGE WIRING; TAP; NOTE: The voltage should be measured at the field power
- Page 15 – START UP; TOPPING OFF SYSTEM CHARGE
- Page 16 – proper rotation; NOTE: If compressor is allowed to run in reverse rotation; PHASE MONITOR; Do not reverse any of the unit factory; CONDENSER FAN OPERATION
- Page 17 – SEQUENCE OF OPERATION; COOLING; COMPRESSOR CONTROL MODULE; Adjustable Delay On Make And Break Timer; delay on make; High Pressure Switch and Lockout Sequence; soft lockout; Alarm Relay Output; NOTE: Both high and low pressure switch controls are; ADJUSTMENTS; Typical Settings for Dual Unit Installation:; PRESSURE SERVICE PORTS
- Page 18 – TROUBLESHOOTING; FIGURE 8; REFRIGERANT CHARGE; Remove the screws holding both grilles, one on each; FAN BLADE SETTING DIMENSIONS
- Page 20 – TABLE 3; Electrical Specifications — W**A Series
- Page 21 – TABLE 4; Electrical Specifications — W**L Series
- Page 24 – HEATER KITS
- Page 25 – VENT & CONTROL OPTIONS
Manual
2100-508F
Page
1 of 25
INSTALLATION INSTRUCTIONS
WALL MOUNTED
PACKAGE AIR CONDITIONERS
MODELS
W17A1
W17L1
W18A1
W18L1
W24A1
W24L1
W30A1
W30L1
W36A1
W36L1
W42A1
W42L1
W48A1
W48L1
W60A1
W60L1
W70A1
W70L1
Manual :
2100-508F
Supersedes:
2100-508E
File:
Volume III Tab 16
Date:
12-15-11
Bard Manufacturing Company, Inc.
Bryan, Ohio 43506
Since 1914...Moving ahead just as planned.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
Manual 2100-508F Page 2 of 25 Contents Figures Figure 1 Fresh Air Damper Assembly ................... 5 Figure 2 Unit Dimensions ...................................... 7 Figure 3A Mounting Instructions .............................. 8Figure 3B Mounting Instructions - W17 – 36 .............. 9 Figure...
Manual 2100-508FPage 3 of 25 GETTING OTHER INFORMATION AND PUBLICATIONS These publications can help you install the airconditioner or heat pump. You can usually find these atyour local library or purchase them directly from thepublisher. Be sure to consult current edition of eachstandard. National E...
Manual 2100-508FPage 4 of 25 WALL MOUNT GENERAL INFORMATION AIR CONDITIONER WALL MOUNT MODEL NOMENCLATURE W 42 A 1 – A 10 X X X X X A NOTE: Vent options X, B and M are without exhaust capability. May require separate field supplied barometric relief in building. SHIPPING DAMAGE Upon receipt of equip...