Bard W24H1D - Manual

Bard W24H1D

Bard W24H1D – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
Page: / 27

Table of Contents:

  • Page 2 – Contents
  • Page 3 – GETTING OTHER INFORMATION AND PUBLICATIONS
  • Page 4 – WALL MOUNT GENERAL INFORMATION; HEAT PUMP WALL MOUNT MODEL NOMENCLATURE; SHIPPING DAMAGE
  • Page 5 – DUCT WORK; Refer to Maximum ESP of operation Electric Heat Tables 7.; NOTE: If no return air duct is used, applicable installation; FILTERS; FIGURE 1
  • Page 6 – INSTALLATION INSTRUCTIONS; WARNING; WALL MOUNTING INFORMATION
  • Page 7 – FIGURE 2; SIDE VIEW
  • Page 9 – FIGURE 3B
  • Page 11 – FIGURE 4; minimum
  • Page 13 – FIGURE 7
  • Page 14 – WIRING – MAIN POWER; must be; WIRING – LOW VOLTAGE WIRING; TAP; NOTE: The voltage should be measured at the field power
  • Page 15 – START UP; TOPPING OFF SYSTEM CHARGE
  • Page 16 – proper rotation; NOTE: If compressor is allowed to run in reverse rotation; PHASE MONITOR; Do not reverse any of the unit factory; CONDENSER FAN OPERATION
  • Page 17 – SEQUENCE OF OPERATION; COOLING; PRESSURE SERVICE PORTS; Low Pressure Switch Bypass Operation
  • Page 19 – TROUBLESHOOTING; A thorough understanding of the defrost; NOTE: If there was no power to 24 volt transformer,; TABLE 1; LED BLINK CODES; BLINK
  • Page 20 – TEMPERATURE F VS. RESISTANCE R OF TEMPERATURE SENSOR
  • Page 21 – FIGURE 9; REMOVAL OF FAN SHROUD; Remove the screws holding both grilles, one on each; REFRIGERANT CHARGE; AIRFLOW; FAN BLADE SETTING DIMENSIONS
  • Page 22 – TABLE 3B
  • Page 23 – TABLE 4; Electrical Specifications — W**H Series
  • Page 25 – TABLES 7
  • Page 26 – HEATER KITS
  • Page 27 – VENT & CONTROL OPTIONS
Loading the manual

Manual

2100-511F

Page

1 of 27

INSTALLATION INSTRUCTIONS

WALL MOUNTED

PACKAGE HEAT PUMPS

MODELS

W18H1
W24H1

W24H1D

W30H1

W30H1D

W36H1

W36H1D

W42H1

W42H1D

W48H1

W48H1D

W60H1

W60H1D

Manual:

2100-511F

Supersedes:

2100-511E

File:

Volume III Tab 17

Date:

02-17-12

Bard Manufacturing Company, Inc.
Bryan, Ohio 43506

Since 1914...Moving ahead just as planned.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Contents

Manual 2100-511F Page 2 of 27 Contents Figures Figure 1 Fresh Air Damper Assembly ................... 5 Figure 2 Unit Dimensions ...................................... 7 Figure 3A Mounting Instructions .............................. 8Figure 3B Mounting Instructions - W18, W24, W30, W36 .... 9 Figure...

Page 3 - GETTING OTHER INFORMATION AND PUBLICATIONS

Manual 2100-511F Page 3 of 27 GETTING OTHER INFORMATION AND PUBLICATIONS These publications can help you install the airconditioner or heat pump. You can usually find these atyour local library or purchase them directly from thepublisher. Be sure to consult current edition of eachstandard. National ...

Page 4 - WALL MOUNT GENERAL INFORMATION; HEAT PUMP WALL MOUNT MODEL NOMENCLATURE; SHIPPING DAMAGE

Manual 2100-511FPage 4 of 27 WALL MOUNT GENERAL INFORMATION HEAT PUMP WALL MOUNT MODEL NOMENCLATURE W 42 H 1 – A 10 X X X X X A NOTE: Vent options X, B and M are without exhaust capability. May require separate field supplied barometric relief in building. SHIPPING DAMAGE Upon receipt of equipment, ...

Other Bard Models

All Bard Other