Bard QH482 - Manual

Bard QH482

Bard QH482 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
Page: / 34

Table of Contents:

  • Page 2 – CONTENTS
  • Page 3 – GETTING OTHER INFORMATION AND PUBLICATIONS; Manual N
  • Page 4 – Series General Information; QT; MODEL NOMENCLATURE
  • Page 5 – ELECTRICAL SPECIFICATIONS CONTINUED ON PAGE 6 TABLE 2A
  • Page 7 – FIGURE 1
  • Page 8 – FIGURE 3; WARNING; FIGURE 2; UNIT
  • Page 9 – must be locked; GENERAL; FIGURE 4
  • Page 11 – DUCT WORK; The QT; series heat pump has provision to attach a; series heat pumps are designed for use with; FILTERS; FIGURE 7; FIGURE 8
  • Page 12 – The
  • Page 13 – SERVICE LIGHT
  • Page 14 – INSTALLATION INSTRUCTIONS; MOUNTING THE UNIT; NOTE: If the exterior wall thickness is between 5; REMOVING LOCKING SCREWS FROM WHEELS
  • Page 15 – The standard Climate Control; WIRING – MAIN POWER; MUST BE; WIRING – LOW VOLTAGE WIRING
  • Page 16 – LOW VOLTAGE CONNECTIONS; Both must be energized; output; il; It is important that the; CAUTION
  • Page 17 – TABLE 4
  • Page 19 – UNIT MOUNTED THERMOSTAT WIRING DIAGRAM
  • Page 21 – START UP; Solid State Electronic Heat Pump Control; IMPORTANT INSTALLER NOTE; verification of proper rotation must be made.
  • Page 23 – R ENERGY RECOVERY VENTILATOR; VENT OPTIONS
  • Page 24 – FRESH AIR DAMPER REMOVAL
  • Page 25 – QERV REMOVAL
  • Page 26 – SEQUENCE OF OPERATION; Cooling; PRESSURE SERVICE PORTS
  • Page 27 – DEFROST CYCLE; may take up to 10 seconds with the
  • Page 28 – TROUBLESHOOTING; TABLE 5
  • Page 29 – CHECKING TEMPERATURE SENSOR; A thorough understanding of the defrost
  • Page 31 – TROUBLESHOOTING GE ECMTM MOTORS CONT’D.; Replacing ECM Control Module
  • Page 33 – COOLING PRESSURE
  • Page 34 – HEATING PRESSURE
Loading the manual

Manual 2100-420H
Page

1 of 34

Models:

QH243

QH302

QH362

QH422

QH482

QH602

QTEC SERIES
PACKAGED HEAT PUMP

INSTALLATION
INSTRUCTIONS

Bard Manufacturing Company, Inc.
Bryan, Ohio 43506

Since 1914 . . . Moving ahead, just as planned.

Manual:

2100-420H

Supersedes:

2100-420G

File:

Vol II Tab 14

Date:

06-28-07

© Copyright 2004

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - CONTENTS

Manual 2100-420HPage 2 of 34 CONTENTS Getting Other Information and Publications For more information, contact these publishers: .......... 3 QT EC General Information QT EC Model Nomenclature .......................................... 4 Shipping Damage .................................................

Page 3 - GETTING OTHER INFORMATION AND PUBLICATIONS; Manual N

Manual 2100-420H Page 3 of 34 GETTING OTHER INFORMATION AND PUBLICATIONS These publications can help you install the airconditioner or heat pump. You can usually find these atyour local library or purchase them directly from thepublisher. Be sure to consult current edition of eachstandard. National ...

Page 4 - Series General Information; QT; MODEL NOMENCLATURE

Manual 2100-420HPage 4 of 34 TABLE 1 FACTORY BUILT-IN ELECTRIC HEAT TABLE s l e d o M A - 3 4 2 H Q A - 2 0 3 H Q B - 3 4 2 H Q B - 2 0 3 H Q C - 3 4 2 H Q C - 2 0 3 H Q A - 2 6 3 H Q A - 2 2 4 H Q A - 2 8 4 H Q A - 2 0 6 H Q B - 2 6 3 H Q B - 2 2 4 H Q B - 2 8 4 H Q B - 2 0 6 H Q C - 2 6 3 H Q C - ...

Other Bard Models

All Bard Other