Bard I48H1D - Manual

Bard I48H1D

Bard I48H1D – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
51 Page 51
52 Page 52
53 Page 53
54 Page 54
55 Page 55
56 Page 56
57 Page 57
58 Page 58
59 Page 59
Page: / 59

Table of Contents:

  • Page 2 – CONTENTS
  • Page 3 – GETTING OTHER INFORMATION AND PUBLICATIONS; Manual N
  • Page 4 – GENERAL; [this header is] preferred to address practices
  • Page 5 – TABLE 1; I-TEC Series General Information; I-TEC MODEL NOMENCLATURE; TABLE 1A
  • Page 7 – Unit Specification Sheet; MIS; FIGURE 1
  • Page 8 – A forklift or a lift rated for the load is required to lift; WARNING; FIGURE 2A — UNIT ON LIFT
  • Page 9 – REQUIRED STEPS AFTER FINAL PLACEMENT; pull; MINIMUM INSTALLATION HEIGHT; BRACKET SECTION; SEISMIC CONSIDERATIONS; WALL MOUNTING BRACKET LOCATION
  • Page 10 – Right Side View; BRACKET WALL SECTION VIEW
  • Page 11 – CENTER OF GRAVITY; FIGURE 3
  • Page 13 – FIGURE 5
  • Page 15 – FIGURE 7B
  • Page 16 – FIGURE 7C
  • Page 17 – DUCT WORK; NOTE: Unit cabinet, supply air duct and duct free; FIGURE 8
  • Page 18 – CONDENSATE DRAIN; If the drain line; WITH NO VENT OPTION; FIGURE 10 — DRAIN LOCATIONS
  • Page 19 – UNIT MOUNTING
  • Page 21 – INSTALLATION INSTRUCTIONS; MOUNTING THE UNIT; THESE INSTRUCTIONS MUST BE; START UP; ” section for information on three phase; COMPONENT LOCATION
  • Page 22 – TABLE 3 — OPERATING VOLTAGE RANGE; The voltage should be measured at the field power; WIRING – LOW VOLTAGE WIRING; output; It is important that the; TABLE 4 — WALL THERMOSTATS; CAUTION
  • Page 23 – BASIC HEAT PUMP WITH NO VENTILATION PACKAGE
  • Page 25 – HEAT PUMP WITH CRV AND CO
  • Page 27 – HEAT PUMP WITH ERV AND CO
  • Page 29 – HEAT PUMP WITH COMBINATION CRV AND DB ECONOMIZER (“N” VENT CODE)
  • Page 30 – TOPPING OFF SYSTEM CHARGE
  • Page 31 – IMPORTANT INSTALLER NOTE
  • Page 32 – SEQUENCE OF OPERATION; COOLING PART LOAD; – Circuit R-Y1 makes at; COOLING FULL LOAD; – A 24V solenoid coil on; HEATING STAGE 2; PRESSURE SERVICE PORTS; To install the Resistor Assembly:
  • Page 33 – SPEEDUP; SEN JMP; jumper must be removed; SPEEDUP; DEFROST CYCLE
  • Page 35 – CRV MOTOR SPEED/CFM CONFIGURATION; OTOR SPEEDS; BLACK
  • Page 36 – CRV SPEED CHANGE TERMINAL ACCESS
  • Page 37 – ECONOMIZER VENTILATION SYSTEM; Operating the
  • Page 38 – ECON. SEQUENCE OF OPERATION; On call from CompleteStat for first stage cooling:; Dehumidification Mode; On call from CompleteStat for dehumidification:
  • Page 39 – HEATING MODE OPERATION; MOTOR SPEED/CFM CONFIGURATION
  • Page 40 – The indoor blower must be run whenever the I-TEC
  • Page 41 – RECOMMENDED CONTROL SEQUENCES; CHANGING TO FULLY MODULATING MODE
  • Page 42 – Note: All performance data is based on; WINTER HEATING PERFORMANCE; PERFORMANCE AND APPLICATION DATA; SUMMER COOLING PERFORMANCE
  • Page 43 – ERV “MANUAL MODE” JUMPER PIN ON “M” TERMINAL
  • Page 44 – VENTILATION AIRFLOW DIAGRAM; Return Air
  • Page 45 – ERV ACCESS
  • Page 46 – CONTROL BOARD CONFIGURATION/SETTING; CONTROL for ERV MODULATING; Carbon Dioxide and Temperature Transmitters; SPECIFICATIONS; CO; Temperature Dependence:
  • Page 47 – C V; to; MENU; CURRENT/VOLTAGE OUTPUT
  • Page 48 – MENU DESCRIPTIONS
  • Page 49 – GENERAL INFORMATION; NOTE: Local conditions can vary and affect the required time; QUARTERLY MAINTENANCE; NOTE: Discoloration and staining of the wheel
  • Page 50 – ANNUAL MAINTENANCE; NOTE: Do not use acid based cleaners, aromatic
  • Page 51 – TROUBLESHOOTING; A thorough understanding of the defrost; CODES
  • Page 52 – CHECKING TEMPERATURE SENSOR; Disconnect temperature sensor from board and from; TABLE 6
  • Page 53 – TROUBLESHOOTING ECMTM 142R OUTDOOR FAN MOTOR; In normal operation, this motor may rock back and
  • Page 54 – • Line power is connected as follows:; is; REPLACING THE MOTOR
  • Page 55 – TROUBLESHOOTING INDOOR ECMTM BLOWER MOTORS
  • Page 56 – Replacing ECM Control Module
  • Page 57 – FAN BLADE SETTING DIMENSIONS; CONTROL CONNECTOR MOTOR HALF; TROUBLESHOOTING ECMTM BLOWER MOTORS
  • Page 59 – PART LOAD COOLING PRESSURE/TEMPERATURE
Loading the manual

Manual 2100-549G
Page

1 of 59

Models:

I30H1

I36H1

I42H1

I48H1

I60H1

I30H1D

I36H1D

I42H1D

I48H1D

I60H1D

I-TEC SERIES
PACKAGED HEAT PUMP

INSTALLATION
INSTRUCTIONS

Bard Manufacturing Company, Inc.
Bryan, Ohio 43506

Since 1914 . . . Moving ahead, just as planned.

Manual:

2100-549G

Supersedes:

2100-549F

File:

Vol. II Tab 14

Date:

11-05-13

MIS-2957 A

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - CONTENTS

Manual 2100-549GPage 2 of 59 CONTENTS Getting Other Information and Publications For more information, contact these publishers: .......... 3General & ANSI Z535.5 Definitions ............................. 4 I-TEC General Information I-TEC Model Nomenclature .........................................

Page 3 - GETTING OTHER INFORMATION AND PUBLICATIONS; Manual N

Manual 2100-549G Page 3 of 59 GETTING OTHER INFORMATION AND PUBLICATIONS These publications can help you install the airconditioner or heat pump. You can usually find these atyour local library or purchase them directly from thepublisher. Be sure to consult current edition of eachstandard. National ...

Page 4 - GENERAL; [this header is] preferred to address practices

Manual 2100-549GPage 4 of 59 GENERAL The equipment covered in this manual is to be installedby trained, experienced service and installationtechnicians. The I-TEC must be installed with the Bardmanufactured IWS wall sleeve and ILG louvergrille accessories. These are sold as separateaccessories. Any ...

Other Bard Models

All Bard Other