Summary
2 Talis Lavatory Faucet 32040XX1 Talis Bidet Faucet 32240XX1 32040XX1 32240XX1 Technical Data Maximum flow rate 2.2 gpm Operating pressure: max. 145 psi Recommended operating pressure: 14.5 - 72 psi Test pressure: 232 psi Hot water temperature: max. 176° F* Recommended hot water temp.: 120° - 140° F...
3 Installation Flush the hot and cold supplies thoroughly before installing the faucet! Place the faucet and sealing washer on the mount- ing surface. If the mounting surface is less than 3/16” thick, trim the sealing washer so that it is even with the bottom of the mounting surface. From beneath th...
4 Use 3/8” compression fittings (not included) to con- nect the supply hoses to the hot and cold stops. Use two wrenches, as shown in the diagram, to prevent hose twisting. For proper operation of the faucet, the hot supply should be on the left, and the cold supply should be on the right. Install t...