Page 3 - Contents
Contents 1.0 ATTO FibreBridge provides storage options ...............................1 ATTO FibreBridge 2370E features, benefitsATTO FibreBridge 2390C/R/D features, benefitsATTO FibreBridge 2400C/R/D features, benefits 1.1 ATTO FibreBridge 2370E ........................................................
Page 6 - ATTO FibreBridge provides storage options; The ATTO FibreBridge; ATTO FibreBridge 2370E features, benefits
1 ATTO Technology Inc. FibreBridge Installation and Operation Manual 1.0 ATTO FibreBridge provides storage options The ATTO FibreBridge ™ family of products provides Fibre Channel-to-SCSI bridges as embeddable boards, stand alone enclosures that can be fitted for rack mount integration, or desktop u...
Page 8 - Configuring the FibreBridge
3 ATTO Technology Inc. FibreBridge Installation and Operation Manual 1.1 ATTO FibreBridge 2370E The ATTO FibreBridge 2370E is a 4-Gigabit Fibre Channel to SCSI bridge offering the ability to add 4-Gigabit Fibre Channel connectivity to Ultra320 SCSI devices. The FibreBridge 2370E is available in an e...
Page 10 - approximately 10 pounds; Operating temperature:; A rechargeable Lithium ion battery cell holds; WARNING
5 ATTO Technology Inc. FibreBridge Installation and Operation Manual 1.2 ATTO FibreBridge 2390R/D The ATTO FibreBridge 2390R/D is a 4-Gigabit Fibre Channel to SCSI bridge offering the ability to add 4-Gigabit Fibre Channel connectivity to Ultra320 SCSI devices. The FibreBridge 2390R/D is available i...
Page 11 - A bicolor Ready/Fault LED
6 Manual reset switch A manual reset switch reboots the FibreBridge.To reset the FibreBridge, depress the reset button for no more than three seconds. To restore factory defaults, press the reset button for more than four seconds until the green Ready LED blinks. LED indicators The LED indicators ca...
Page 12 - Height of tallest component:; Ready; Fibre Channel port:; NU 5V GND 5V 5V GND
7 ATTO Technology Inc. FibreBridge Installation and Operation Manual 1.3 ATTO FibreBridge 2390C The ATTO FibreBridge 2390C is a 4-Gigabit Fibre Channel to SCSI bridge offering the ability to add 4-Gigabit Fibre Channel connectivity to Ultra320 SCSI storage devices. The FibreBridge 23900C is availabl...
Page 13 - lights green to indicate
8 Embedded in the Ethernet port connector: a lighted green LED shows a valid link; off indicates that no link is present. A separate blinking yellow LED indicates activity. A bicolor Ready/Fault LED lights green to indicate ready, lights yellow to show a faulted condition, and is off to indicate not...
Page 18 - Install the FibreBridge; Unpack the packing box verify contents; Cabling; CAUTION; Discover the IP address; Next
13 ATTO Technology Inc. FibreBridge Installation and Operation Manual 2.0 Install the FibreBridge If you have not already completed the instructions on the Quick Start page packed with your FibreBridge, use the following instructions to install the FibreBridge. Unpack the packing box; verify content...
Page 19 - Internet Explorer setup; Interface options
14 If you do not have a DHCP server, get an IP address and subnet mask from your network administrator, type it into the area provided, and click on Next . 5 Click on Launch Browser Your browser points to the ATTO ExpressNAV splash screen. If you use Internet Explorer as a browser, continue on to In...
Page 20 - Configure the FibreBridge; Restart; Modify passwords
15 ATTO Technology Inc. FibreBridge Installation and Operation Manual 3.0 Configure the FibreBridge To configure the ATTO FibreBridge, use ATTO ExpressNAV. Default values are appropriate for most configurations, but may be modified.The ExpressWizard provides one-button setup for many applications. T...
Page 22 - FibreBridge mapping; To identify each Fibre Channel device; Soft addressing; allows the loop initialization; Hard addressing; allows a predetermined address; SCSI device mapping
17 ATTO Technology Inc. FibreBridge Installation and Operation Manual 3.1 Map devices After getting an IP address and entering ATTO ExpressNAV, you must map devices so that the FibreBridge can access the devices in your network. The ATTO FibreBridge allows parallel SCSI devices to participate in a F...
Page 25 - SNMP-based monitoring
20 SNMP-based monitoring The Simple Network Management Protocol (SNMP) facilitates the exchange of management information between network devices. An agent resides in the FibreBridge which takes information from the FibreBridge and translates it into a form compatible with SNMP. If certain condition...
Page 26 - Email messages provide error notification
21 ATTO Technology Inc. FibreBridge Installation and Operation Manual Email messages provide error notification Email notification allows the FibreBridge to send an Email message to you, a network administrator or other users when certain events occur. Serious error messages are sent immediately, wh...
Page 27 - Event
22 Exhibit 3.0-5 The Email messages sent by the FibreBridge follow this format. Subject: [The Type of Event that Occurred] Message Body:This is a status message from [FibreBridge name]. Identifying information as well as the most recent entries from the event log appear below. *************** Unit I...
Page 28 - Update firmware; command from an FTP connection, or; Preliminary step; The FibreBridge firmware is distributed as an; Using FTP
23 ATTO Technology Inc. FibreBridge Installation and Operation Manual 4.0 Update firmware The ATTO FibreBridge has several processors which control the flow of data. The firmware to control these processors can be upgraded in the field using the PUT command from an FTP connection, or ZModem utility ...
Page 29 - Send File
24 6 In the Send File box, enter the current FibreBridge .ima file or click the browse button to find it. 7 Click Send File 8 The FibreBridge acknowledges receiving the file and displays a message not to interrupt power for 90 seconds. Once the download is complete, cycle power on the FibreBridge to...
Page 30 - Interface options; Advanced CLI; Opening an ExpressNAV session; Submit; on the page you are viewing, go; page and restart the Fibre Bridge to; Using the serial port
25 ATTO Technology Inc. FibreBridge Installation and Operation Manual 5.0 Interface options Alternative methods to the ATTO ExpressNAV interface may be used to manage the Fibre Bridge. ATTO ExpressNAV is the recommended interface. Using ExpressNAV Each page in the ATTO ExpressNAV interface provides ...
Page 31 - Using Telnet; set; CLI command can continue to issue; get; commands or display information. Once a; CLI provides; on page ii of the Appendix.
26 • Flow Control: None• Terminal type: ASCII• Echo: on f. Click OK. 4 After you connect to the Fibre Bridge, start-up messages are displayed. These messages are only displayed at start-up. The last line in the start-up message sequence is Ready . 5 In serial port sessions, there is no prompt on the...
Page 32 - Appendix A Cabling; SCSI port connections
i ATTO Technology Inc. FibreBridge Installation and Operation Manual Appendix A Cabling ATTO FibreBridge SCSI ports connect SCSI storage devices into the Fibre Channel Storage Area Network (SAN). Use an Ethernet connection to use the ATTO ExpressNAV interface. Make sure all cables are anchored secur...
Page 33 - ii; Appendix B CLI provides ASCII-based interface; Services through a set of
ii Appendix B CLI provides ASCII-based interface The command line interface (CLI) provides access to the ATTO FibreBridge Services through a set of ASCII commands. CLI commands may be entered while in CLI mode. FibreBridge Services provide configuration and monitoring for the FibreBridge. The comman...
Page 34 - iii; CLI error messages; CLI summary reference; Command
iii ATTO Technology Inc. FibreBridge Installation and Operation Manual CLI error messages The following error messages may be returned by the Command line Interface ERROR. Invalid Command. Type 'Help' for command list. ERROR. Wrong/Missing Parameters Usage: <usage string> ERROR. Command Not Pr...
Page 35 - iv
iv EthernetSpeed auto set ethernetspeed 100 EventLog enabled set eventlog disabled EventLogFilter all all all set eventlogfilter gen info enabled Exit exit FCConnMode loop set fcconnmode all ptp FCDataRate auto get fcdatarate 1 FCHard disabled set fchard enabled FCHardAddress set fchardaddress 1 122...
Page 37 - Command explanations; Regulates the ports to be used for a boot scan.
vi Command explanations AutoLogSense Controls whether current data from log pages in a SCSI target device is available automatically. Default: disabledset AutoLogSense [enabled|disabled]Requires a SaveConfiguration commandget AutoLogSense AutoMap Automatically assigns a subset of source protocol LUN...
Page 38 - vii; DisplayEventLogFilter; single page with no user interaction. After the; a single page with no user; quit; Cx; DisplayTraceLog
vii ATTO Technology Inc. FibreBridge Installation and Operation Manual DisplayEventLog Displays the event log. The event log may be filtered using the DisplayEventLogFilter command. The optional parameter n is the number of lines to be displayed as a single page with no user interaction. After the c...
Page 39 - viii
viii EmailNotifyAddress Configures notification addresses. Index is a number 1-5. Full Email address is a fully qualified Internet Email address, not more than 128 characters long. Warning level can be All, Warning , Critica l or None . None means no Emails are sent; Critical means only critical sev...
Page 40 - ix; FCHardAddress; FCHard; Reset; Invalid Transmission Word; Reserved
ix ATTO Technology Inc. FibreBridge Installation and Operation Manual FCHard Regulates FC hard address assignment. Under soft addressing, the FibreBridge loop address is assigned during loop initialization. Use FCHardAddress if you enable hard addressing. Default: disabledset FCHard [enabled | disab...
Page 41 - forced; IPDHCP
x FirmwareRestart Causes the FibreBridge to reboot, then re-initialize its firmware.Use the forced option to override any CLI reservation held by other sessions. FirmwareRestart <forced> Help Displays a list of available commands. If command name is specified, displays detailed command-specifi...
Page 42 - xi; VerboseMode; FCPortErrors
xi ATTO Technology Inc. FibreBridge Installation and Operation Manual MinOpTemp (FB2390, FB2400 only) Regulates/displays the minimum enclosure temperature alarm of the FibreBridge in degrees Celsius.Valid entries are between 0 degrees and 15 degrees Default: 0set MinOpTemp [0-15]Requires a SaveConfi...
Page 43 - OK
xii Route Assigns a Fibre Channel address to a target destination device. If you try to map a new SCSI BTL to the same FC LUN, the new BTL overwrites the previous map. Using the delete identifier removes the map from its table. If VerboseMode has been enabled, overwriting an existing map requires se...
Page 44 - xiii; disabled
xiii ATTO Technology Inc. FibreBridge Installation and Operation Manual SCSIPortTermination Configures/reports the SCSI internal termination of the SCSI port identified on the FibreBridge.Enabling termination allows the FibreBridge to act as a terminator at the end of a SCSI chain. Default: enableds...
Page 45 - Displays new events to the terminal. Type; Time
xiv SNMPTrapAddress Sets/displays the IP trap addresses and levels.Consult your network administrator for further assistance with SNMP. Index: value between 1 and 6IPAddress: standard IP address for the host receiving messages; must be in the same subnet as the FibreBridge Trap Level: severity requi...
Page 46 - xv; Controls/displays the time zone if
xv ATTO Technology Inc. FibreBridge Installation and Operation Manual TimeZone Controls/displays the time zone if SNTP is disabled. Setting may be EST, CST, MST PST or a numerical offset from GMT in the format +/- HH:MM. When SNTP is enabled, applies the time zone setting to the time retrieved from ...
Page 47 - xvi; zModem
xvi zModem Allows transfer of a firmware image to or from the FibreBridge using the zModem file transfer protocol. Available only through the RS232 interface. zModem [Send filename | Receive] CAUTION CAUTION After a firmware image is downloaded to the FibreBridge, the image is placed into flash memo...
Page 48 - xvii; Appendix C Standards and compliances; FCC Standards: Radio and Television Interference; The booklet; Canadian Standards; Declaration of Conformity
xvii ATTO Technology Inc. FibreBridge Installation and Operation Manual Appendix C Standards and compliances The equipment described in this manual generates and uses radio frequency energy. If this equipment is not used in strict accordance with the manufacturer's instruction, it can and may cause ...
Page 49 - xviii; Certification for the FibreBridge 2400 only
xviii In addition the FibreBridge 2370E conforms to EN55024.This Declaration will only be valid when this product is used in conjunction with other CE approved devices and when the entire system is tested to the applicable CE standards and found to be compliant.The ATTO FibreBridge 2370E, 2390 and 2...
Page 50 - xix; Appendix D Warranty information
xix ATTO Technology Inc. FibreBridge Installation and Operation Manual Appendix D Warranty information Manufacturer limited warranty Manufacturer warrants to the original purchaser of this product that it will be free from defects in material and workmanship as described in the ATTO Technology websi...
Page 51 - xx