ATD ATD5496 - Manual
ATD ATD5496 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
ATD
‐
5496
Meter
Calibration
z
It
is
strongly
recommended
that
the
following
steps
should
only
perform
by
professional
people.
z
Please
wear
safety
goggles
and
gloves
before
performing
the
following
procedures.
z
The
following
procedures
should
only
be
performed
when
the
meter
reading
is
tested
and
confirmed
out
of
accuracy.
1.
Test
a
battery
by
DVOM
and
record
the
voltage.
This
voltage
will
be
considered
as
the
standard
voltage
in
the
following
adjustment.
So
it
is
important
to
make
sure
the
voltage
is
correct.
2
Disassemble
the
ATD5496
you
can
find
a
yellow
calibration
screw
on
back
of
PCB
board
(Fig...).
The
adjustment
can
be
made
by
turning
this
calibration
screw.
2.1
Connect
the
battery
to
ATD5496,
and
at
the
meantime,
turn
the
calibration
screw
until
needle
points
to
the
standard
voltage.
(i.e.
if
standard
voltage
is
12.4V,
adjust
the
needle
to
12.4V)
2.2
Disconnect
battery
and
then
re
‐
connect
battery
to
make
sure
that
the
readout
is
same
as
standard
voltage.
If
not,
need
repeat
step
2.1.
If
yes,
the
calibration
is
finished.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.