ATD ATD3699

ATD ATD3699 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
Page: / 4

Table of Contents:

  • Page 2 – INTRODUCTION; FEATURES; Product Specifications
  • Page 3 – Polarity Mark; Operating Instructions
  • Page 4 – Leak Size Indicator; regardless of the sensitivity; Low Battery Indicator; Maintenance; Audio Mute Function; Remove the plastic seal cap on top of the Leak Test Vial
Loading the manual

Replacement Parts

Item

Part Number

Sensor with Filter

PRT3700-01

Filter Kit

PRT3700-02

Test Vial

PRT3700-03

Carrying Case

PRT3699-CASE

Instruction Manual

PM-MAN0010

RETURN FOR REPAIR POLICY


Every effort has been made to provide reliable, superior quality
products. However, in the event your instrument requires repair,
forward unit to Service Center freight prepaid to the address below
with return address, phone number and/or email address.

SERVICE CENTER

2651 W 81st Street

Hialeah, FL 33016

WARRANTY POLICY


The ATD3699 Refrigerant Gas Leak Detector is warranted to be
free of defects in materials and workmanship for a period of two
years from the date of purchase including an industry first two year
warranty on the sensor. This warranty applies to all repairable
instruments that have not been tampered with or damaged through
improper use including unauthorized opening of the unit. Please
ship warranty units that require repair freight prepaid to Service
Center along with proof of purchase, return address, phone number
and/or email address.








































Model ATD3699

Refrigerant Gas Leak Detector

User Manual

Detects all CFC, HFC, HCFC

Refrigerants including blends

Design Certified to meet

SAE J2791 and EN14624

For R134a

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - INTRODUCTION; FEATURES; Product Specifications

INTRODUCTION The ATD3699 features a long life heated sensor technology that is designed to detect the more current and difficult HFC refrigerants such as R-134a, R-410a, R-407c, R-507, and R-404c in addition to all HCFC (R22) and CFC (R12) refrigerants including SNAP approved hydrocarbon blends. The...

Page 3 - Polarity Mark; Operating Instructions

Maintenance Filter Keyway alignment Pull straight out (do not twist) to remove sensor Unscrew tip to replace filter Push straight on (do not twist) to install sensor Batteries: Install Batteries : Remove screw located at rear end of unit and pull down hinged battery door to open as shown. Always ins...

Page 4 - Leak Size Indicator; regardless of the sensitivity; Low Battery Indicator; Maintenance; Audio Mute Function; Remove the plastic seal cap on top of the Leak Test Vial

Leak Size Indicator The digital leak size indicator remains off normally but once a leak is detected, a number from 1-9 will be displayed for all HFC and HCFC refrigerants regardless of the sensitivity setting. The number will continue to increase or decrease depending on the amount of refrigerant s...