DELUXE DUAL BRASS A/C MANIFOLD

GAUGE SET

WARNING:

Always wear safety goggles when working with

refrigerants. Contact with refrigerant can cause eye injury.

Disconnect hoses with extreme caution! Pressurized

refrigerant may be present in hoses. Always point hoses

away from you and anyone nearby.

Your manifold is designed so that all three lower fittings are connected to each other by internal passages.

Separate passages from the low and high side fittings to their respective gauges give you pressure and

vacuum readings whether the handwheels are open or closed. For your convenience and safety, handwheels

and gauges are color-coded with the blue compound gauge on the left or low side, and the red pressure gauge

on the right or high side.

Diagnosing System Operation

·

Connect the blue low side hose to the A/C system’s low side service port. Connect the red high side

hose to the A/C system’s high side service port.

·

With the manifold handwheels closed, read the pressure on the gauge face.

·

Use the temperature/pressure chart in the back of this manual to find the corresponding temperature

for the refrigerant in the system.

·

Compare these pressure and temperatures to the A/C system manufacturer’s specifications for proper

operation.

·

If the system is within the correct operating guidelines, disconnect the manifold hoses from the system.