Armstrong EHU-701 - Manual

Armstrong EHU-701

Armstrong EHU-701 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
Page: / 40

Table of Contents:

  • Page 2 – To protect yourself and others from accidental shocks:; SWITCH BEFORE OPENING ANY COVERS!
  • Page 3 – TABLE OF CONTENTS; SECTION 1: PREPARATION AND INSTALLATION
  • Page 4 – Electronic steam humidifiers
  • Page 6 – INSTALLATION; ) MOUNTING THE HUMIDIFIER; b. USE ONLY WIRE WITH COPPER CONDUCTORS RATED 90°C OR HIGHER
  • Page 7 – ) WATER FILL SUPPLY; ORDINARY (POTABLE) TAP WATER IS RECOMMENDED. IF POTABLE WATER IS NOT; DRAIN; a. Verify that the proper length and type of
  • Page 8 – MUST BE
  • Page 9 – Pressure Loss in Copper Pipe
  • Page 10 – Wall Mounted Control Humidistat:; space to be humidified.
  • Page 11 – Ohm Potentiometer
  • Page 12 – Micro Controller
  • Page 13 – INSTRUMENT PANEL
  • Page 14 – START-UP PROCEDURE FOR ARMSTRONG SERIES EHU-700 HUMIDIFIERS; BEFORE TURNING ON THE POWER; ) Examine the wiring and the components; TURN ON POWER AT THE CIRCUIT BREAKER; seconds later the Fill Light will go on. The unit will begin to fill.; Contactors
  • Page 16 – 7) Close and lock the doors, and store the key away from the unit.
  • Page 17 – TROUBLESHOOTING GUIDE; PRINCIPLE OF OPERATION - AN OVERVIEW; The Armstrong Series EHU-700 electronic steam humidifier
  • Page 18 – of; ALL; of the following occur:; Monitoring Stat Demand:
  • Page 19 – Automatic Drain Operation:
  • Page 20 – DIAGNOSTIC DISPLAY MESSAGES; * Automatic shutdown and Alarm contact closure.; NORMAL OPERATION
  • Page 23 – WATER QUALITY AND TREATMENT FOR EHU SERIES HUMIDIFIERS; Mhos. For conductivity greater than 800
  • Page 24 – alone
  • Page 25 – Electronic Steam Humidifier
  • Page 26 – Valves and Mechanical Parts
  • Page 27 – Electrical Parts; Item
  • Page 29 – MAINTENANCE; unit with a malfunctioning drain system
  • Page 30 – TANK REMOVAL AND REPLACEMENT - ALL MODELS; ) Turn steam generator tank off by pressing tank off button.
  • Page 31 – STEAM GENERATOR CHEMICAL CLEANING PROCEDURE; ) Let the steam generator tank cool after removal from the EHU unit.
  • Page 33 – TANK DISASSEMBLY, CLEANING, AND ELECTRODE REPLACEMENT; MODELS EHU-703 AND 704, SINGLE AND THREE PHASE; clip with the other hand.; BOTH THE BARRIER ASSEMBLY AND; ) Install the electrode jumper wires to the studs at the
  • Page 35 – duct pressure where the dispersion tube is mounted. A; negative; duct pressure can cause; WAS NOT; found, check the continuity of the wires back to the circuit board.; WAS; ) If the valve makes humming or buzzing noises but fails to open:
  • Page 36 – HUMIDISTAT DATA; AUTOCAL PROCEDURE; Accuracy and sensor interchangeability:
  • Page 37 – Base; HUMIDITY SENSOR OUTPUT
  • Page 38 – was set to; Control Output Le
  • Page 39 – APPLICATION EXAMPLE
  • Page 40 – Dimensions; Armstrong
Loading the manual

Installation and Maintenance

Series EHU-700 Humidifiers

Please Read And Save These Instructions

The Armstrong Series EHU-700 humidifier is an electronically controlled, non-pressurized steam-generating
humidifier, with its vapor discharged into a duct of an air-handling system or through a fan package. The

Armstrong Series EHU-700 consists of three models: The EHU-701, 703 and 704. The maximum capacity

of the series is 240 Ibs/hr.

To allow the Series EHU-700 humidifier to function to its full capability, be certain to install it in accordance
with the following Armstrong recommendations. For further assistance, please contact your local Armstrong
representative for the video tape, "Armstrong Series EHU-700 Humidifiers: Installation, Operation and
Maintenance".

Bulletin 527-G

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - To protect yourself and others from accidental shocks:; SWITCH BEFORE OPENING ANY COVERS!

DANGER ELECTRICAL SHOCK HAZARD HIGH VOLTAGES EXIST INSIDE THE HUMIDIFIER To protect yourself and others from accidental shocks: 1. Keep the humidifier locked during normal operation and store the key in a safe location away from the humidifier. 2. ALWAYS DISCONNECT THE POWER SUPPLY AT THE CIRCUIT BR...

Page 3 - TABLE OF CONTENTS; SECTION 1: PREPARATION AND INSTALLATION

TABLE OF CONTENTS 3 SECTION 1: PREPARATION AND INSTALLATION WARNINGS.................................................................................................................. 2 PRE-INSTALLATION......................................................................................................

Page 4 - Electronic steam humidifiers

PRE-INSTALLATION 1) CHECK SHIPMENT A claim should be filed with the transportation company (and reported to Armstrong) if any items are missing or damaged. Your shipment will arrive in two or three cartons. One carton holds the humidifier with the steam generator installed, the control humidistat an...

Other Armstrong Models

All Armstrong Other