Armstrong 6300 - Manual

Armstrong 6300

Armstrong 6300 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
51 Page 51
52 Page 52
Page: / 52

Table of Contents:

  • Page 4 – current should be less than 30mA; Model Description; A = Rated voltage of unit is 208V; Do not install; Refer to Installation section for other details regarding site; Series HumidiCleanTM Humidifiers
  • Page 6 – Installation; studs or other sturdy structure.; Water Fill Supply
  • Page 7 – Drainage; Table 7-2. Steam Capacities and Rating Amperages
  • Page 8 – Duct Steam Distribution
  • Page 9 – Area Steam Distribution; for more; Alternative for shortened non-wettable vapor trail; for more information.; Control Wiring; Control Humidistat; below for correct switch settings.
  • Page 12 – Duct pressure switch will be wired in series with high limit; Alarm Circuit
  • Page 13 – Display Menu; Run Menu
  • Page 14 – Operation Setup
  • Page 15 – Operation Setup - Continued
  • Page 16 – Unit Configuration; tightness of connections.
  • Page 17 – Principle of Operation
  • Page 18 – Save the settings, consult the OPERATION SETUP; Ionic Bed Inspection; Reset the Ionic Bed service life; Ionic Bed Replacement
  • Page 19 – ) Complete the steps for servicing the unit as outlined above.; End of Season Drain; menu
  • Page 20 – secure tank access panel.
  • Page 21 – Cleaning the Water Level Electrodes; should energize, and the unit should completely drain.
  • Page 22 – Unlock and open front and side doors. Remove left side panel.; Troubleshooting; KNOW WHERE THE HIGH VOLTAGE PARTS ARE, AND; All resistance checks should be made with; Humidifier will not fill with water when power is applied.
  • Page 23 – PC board. If continuity is OK, the PC board is likely defective.
  • Page 24 – Humidifier overfills with water on initial fill.; clean or replace valve.
  • Page 25 – Humidifier does not drain when manual drain.
  • Page 26 – Dispersion tube spits water or water is present in duct; recommended to prevent this. See Installation section.; Water in bottom of cabinet; Check steam distribution piping for obstructions.; Diagnostics; FILL TIME OUT TO LOW LEVEL; - - The low level switch has not closed after 35 minutes of fill
  • Page 30 – HC6100-PAR Single Phase Wiring Layout
  • Page 39 – Heating Elements
  • Page 43 – Procedure of HC6000 Version 7 Soft Refresh; Before refreshing the code, the old code in CPU must be erased:
  • Page 46 – Introduction to Communications; can select different modules to connect different port)
  • Page 47 – Table 46-1 Modbus Variable Lists
  • Page 50 – Physical Data, Capacities and Dimensional Drawings
  • Page 52 – Limited Warranty and Remedy; DOES NOT MAKE ANY OTHER REPRESENTATIONS OR WARRANTIES, EXPRESS OR; The Limited Warranty and Remedy; armstrong
Loading the manual

HumidiClean

Series HC- 6100/6300/6500/6700

Humidifiers

Installation, Operation and

Maintenance Instructions

Table of Contents

Page

Warning Labels

2-3

Description of Model Number

4

Installation

6-12

Display Menu

13-16

Start-Up Procedure and Operation

16-17

Maintenance

18-22

Troubleshooting

22-27

Typical Wiring Schematic

28-37

Repair Parts

36-42

Software Update

43-46

Communication

46-51

Warranty

52

Please read and save these instructions.

Bulletin 539-A

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 4 - current should be less than 30mA; Model Description; A = Rated voltage of unit is 208V; Do not install; Refer to Installation section for other details regarding site; Series HumidiCleanTM Humidifiers

• This disconnecting switch should have leakage current protecting function. The max leakage current should be less than 30mA • The disconnecting switch should have a breaking capacity sufficient to interrupt the largest normal running current of loads. The breaking capacity required should be selec...

Page 6 - Installation; studs or other sturdy structure.; Water Fill Supply

Installation HC-6100/6300 Mounting The HumidiClean models HC-6100/6300 are designed to be wall mounted. A wall mounting bracketand lag screws are provided for mounting on 410 mm (16”) centers. The operating weight of the unit is106 kg (233 lbs). A clearance of 600 mm (23”) on the front and sides of ...

Page 7 - Drainage; Table 7-2. Steam Capacities and Rating Amperages

Drainage Connect HC-6000 drain to suitable waste drainage system. HC-6000 drain water may be as hot as 70°C (158°F). Use clear drain hose provided and 25 mm (1”) copper pipe pitched away from unit at 25 mm (1”) inch per foot. An air gap to prevent back flow is required. See Figure 7-1. 7 1-12 13-15 ...

Other Armstrong Models

All Armstrong Other