Page 2 - Arcode Quick Installation Guide V2.10; Arkel Elektrik Elektronik San. ve; Date of issue
Arcode Quick Installation Guide V2.10 Publisher Arkel Elektrik Elektronik San. ve Tic. A.Ş. Eyüp Sultan Mah. Şah Cihan Cad. No:69 Sancaktepe/Istanbul 34885 TURKIYE Tel: (+90 216) 540 03 10-11-12 Fax: (+90 216) 540 03 09 E-mail: [email protected] www.arkel.com.tr Date of issue 08.2020 Document versio...
Page 3 - CONTENTS
Arcode Quick Installation Guide V2.10 CONTENTS 1. MECHANICAL INSTALLATION ................................................................................................................................... 4 2. MOTOR CONNECTIONS ..........................................................................
Page 4 - MECHANICAL INSTALLATION; Mounting holes; dimensions and type can change depending on; Don’t mount it on; Figure-1: Dimensions of battery pack (it is required only when the
Arcode Quick Installation Guide V2.10 1. MECHANICAL INSTALLATION Mount Arcode control cabinet, brake resistor, battery pack and UPS (if required) to their places. Figure-2b: Arcode 18cm 32,5cm 11,5cm Mounting holes Mounting holes 22,5cm 30,5cm 15,5cm Figure-2a: Arcode control panel (Control panel di...
Page 5 - MOTOR CONNECTIONS
Arcode Quick Installation Guide V2.10 2. MOTOR CONNECTIONS Make the connections of motor phases & motor PTC, brakes & brake release contacts, motor fan, encoder, brake resistor and battery pack with UPS (if required). 5 4 1 : Motor phases & motor PTC connections Motor phases Motor PTC C ...
Page 6 - PREPARATIONS FOR AUTO-TUNE; If the control pane isn’t EN81; Figure-7a: bridging of top and bottom limit switches; Control Panel Terminals:
Arcode Quick Installation Guide V2.10 Figure-5: UPS connections ***If there is SERVOSAN brand UPS inside the control panel these connections are not used. ***If you do not have UPS you must bridge connectors U-LI with U-LO and U-NI with U-NO using with suitable cables. Otherwise you can not run cont...
Page 8 - recall switch on the recall hand terminal to “REV” position. In this; c: “Device Parameters” settings
Arcode Quick Installation Guide V2.10 • Activate the manual operation mode by turning the recall switch on the recall hand terminal to “REV” position. In this case the motor can be moved by recall buttons from the control panel. • Turn on SMP main braker after opened all circuit breakers (fuses). • ...
Page 9 - If motor doesn’t have; Other
Arcode Quick Installation Guide V2.10 • “Maximum travel speed” , “inspection mode - speed” and “recall speed” which is located in “Travel curve settings” should be set according to motor speed. • The nominal speed which is written on motor plate must be used for parameter “Maximum travel speed”. • P...
Page 10 - PREPARATIONS FOR NORMAL OPERATION; Learning” is selected.; Asynchronous
Arcode Quick Installation Guide V2.10 • Arcode can do auto-tune both with ropes and wihtout ropes. To run it, the cursor should be aligned icon of “Auto - tune” and press Enter button. • When pressed Enter button, if gearless machine is used, Figure-11b appears on the screen, if geared machine is us...
Page 11 - SHAFT LEARNING & TEST DRIVE; Figure-14: Installation of magnets for SML1-SML2 door zone sensors; The deceleration distance is; Figure-12: Installation of magnets for SKSR1 bottom; sensor; Figure-13: Installation of magnets for SKSR2
Arcode Quick Installation Guide V2.10 • Make the installation of round magnets for SKSR2 top limit switch (top correction sensor). The cables of SKSR2 magnetic switch must be connected 100 and 818 terminals in IBC-S board. Round magnets of top limit switch must be put as shown Figure-13. • Make the ...
Page 12 - reason, press the “Emergency Stop” button or take the lift; 7: give a call by “COP and LOP calls”
Arcode Quick Installation Guide V2.10 • Select icon of “Shaft learning” in the menu and press Enter button. You can run shaft learning procedure pressing by “F2” button. • The shaft learning procedure depending on the length of the shaft, this may take a while. You can follow stage of shaft learning...
Page 13 - LANDING & CAR CALL SETTINGS; “Tools”; will see “A” “+” and def; Figure-18c: LOP position learning screen
Arcode Quick Installation Guide V2.10 7. LANDING & CAR CALL SETTINGS Car Calls: • CPC or CPC-T (Car Panel Controller) boards are used to give car calls. These are connected to IBC-S (Inspection Box Controller) board by serial communication. if dipswitch settings were done which is shown in secti...
Page 14 - OTHER SETTINGS; Deceleration Distance
Arcode Quick Installation Guide V2.10 LOP learning: • If the car is at bottom floor and LOP display shows “ ?? ” or wrong landing floor, you must hold down call button of LOP until appears correct floor number on LOP screen. For first floor door A you must see “ A ” “+” and ” 1 ” respectively. If yo...
Page 15 - SOFTWARE UPDATE; When AREM is first connected to the CANBus line, if; firmware; icon and pres; ARCODE PERIPHERALS; The communication between control panel and car is
Arcode Quick Installation Guide V2.10 9. SOFTWARE UPDATE When AREM is first connected to the CANBus line, if AREM’s SD card does not have the software which exsist on Arcode, AREM will inform that an update is needed. Start the update pressing the button F1. The system will be restarted when the upd...
Page 16 - CAR PANEL CONTROLLER BOARDS; SETTINGS OF CPC BOARD; CAN can’t be used with; Table-1: dipswitch settings of CPC board
Arcode Quick Installation Guide V2.10 BC-LCDA: 128x64 resolution LCD. The LCD can be used inside the car as an indicator or on the landing as an indicator and call button. BC-LCD240128: 240x128 resolution LCD. The LCD can be used inside the car as an indicator or on the landing as an indicator and c...
Page 17 - “IO; SETTINGS OF MSP-16 BOARD
Arcode Quick Installation Guide V2.10 11.4. SETTINGS OF IO-0210 BOARD In some cases, programmable inputs and outputs may not be enough. Then, this IO-0210 board would be useful. This board gives 2 inputs and 10 transistor outputs to the user. There are 8 dipswitches. The logic of these dipswitches i...
Page 18 - SETTINGS OF MSP-32 BOARD
Arcode Quick Installation Guide V2.10 11.6. SETTINGS OF MSP-32 BOARD MSP-16 can serves up to 9 floors for full collective. If the system full collective and more than 9 stops MSP -32 board is used. Dipswitch settings must be set according to Table-7. Check electrical diagram for more information. Ta...
Page 19 - MEANING OF 7-SEGMENT MESSAGES ON ARCODE; but the car isn’t at door zone.; CLEARING OF PERMANENT ERRORS
Arcode Quick Installation Guide V2.10 12. MEANING OF 7-SEGMENT MESSAGES ON ARCODE INIT: Elevator goes bottom floor for reset (Initialising) UpEn: Enca board is being updated (Updating Enca) O-in: Only inspection notu: Needed autotuning (No Tuning) noSh: Needed Shaft learning (No Shaft Learning) 120-...
Page 20 - NEW FUNCTIONS WHICH ARE COMING WITH EN81-20; ‘nominal slip frequency’ parameter
Arcode Quick Installation Guide V2.10 14. NEW FUNCTIONS WHICH ARE COMING WITH EN81-20 By-Pass key The pacco switch is used to bridge safety circuit for maintenance purpose. • The key which has 4 positions can bridges only one part of the safety circuit in same time. • Position 0: No bridge in that p...
Page 21 - transmitted to switches’ contacts.
Arcode Quick Installation Guide V2.10 08- Current was near driver limit continuously: If the motor current exceeds over 250% of max. current of IPM module for 6 seconds, it gives this error. • Be sure that load balance is completed correctly. • Check the machine brake is being opened completely. • C...
Page 22 - power is transmitted to the motor and it doesn’t reach the desi
Arcode Quick Installation Guide V2.10 18- Car overspeeded: This error is faced if the speed information from the encoder is above the calculated speed. • Encoder connections must be checked. Motor parameters must be checked. • The elevator’s load balance must be set correctly. Load balance must be c...
Page 24 - “not used” or the limit
Arcode Quick Installation Guide V2.10 37- 140 interrupted during travel: If 140 does not exist for 50 milliseconds during movement, it gives this error. Door close signal might cutted of during movement. Check the signal and door connections. 38- Encoder position was too different from magnet readin...
Page 25 - Door A; OPEN
Arcode Quick Installation Guide V2.10 54- OGD Error: A shaky starting occurs when the anti roll back value is entered too high. This error may be faced with in this case. Decrease gains of anti roll back. 55- Contactor dropped: When the travel starts, during movement, if 100 signal is cut for 100 mi...
Page 27 - Liftsense
Arcode Quick Installation Guide V2.10 Liftsense ”, when the car waits at floor, if the value which is read from Liftsense should be in the interval of +7 cm -7 cm. Otherwise it gives this error. Note: This is a permanent error. In order to get rid of the permanent error case, look at Page 19. 88- Ov...