Ariston 41-116-07 - Manual

Ariston 41-116-07

Ariston 41-116-07 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
Page: / 48

Table of Contents:

  • Page 2 – TABLE OF CONTENTS
  • Page 3 – Check the following at least once a year:; ENERAL
  • Page 4 – VERALL
  • Page 5 – INSTALLATION
  • Page 11 – Sum of the total length of e; ABLE; WIN
  • Page 12 – To connect a room thermostat and/or time clock, it is necessary to:; A frost thermostat is built-in to the appliance.; OOM
  • Page 13 – Blk
  • Page 14 – AS AND
  • Page 15 – selection of ARISTON unvented cylinders).; port valve installation
  • Page 17 – COMMISSIONING; Boiler microSYSTEM; The kit (ARISTON par t number
  • Page 18 – - Central Heating button
  • Page 19 – The flue connector has two aper tures,
  • Page 20 – P of operation of the air
  • Page 21 – HANGING THE; GAS ADJUSTMENTS; Methane Gas
  • Page 22 – MAINTENANCE
  • Page 24 – Merloni TermoSanitari SpA - Italy; bief; TECHNICAL INFORMATION
  • Page 25 – Country of destination: GB
  • Page 26 – TABLE OF CONTENTS
  • Page 27 – SERVICING INSTRUCTIONS; EPLACEMENT OF; Loosen the fastening screws “A” of the control panel located on
  • Page 28 – Removing the sealed chamber front cover; Lift the sealed chamber front cover from the locating pins
  • Page 29 – To remove the detection electrode disconnect the cable; Remove the screws “F” from the burner (F; CCESS TO THE
  • Page 30 – Gently slide the electrode downward (F; otherwise the electrode may break; Release the two connection nuts “J” connecting the; Remove the heat exchanger by sliding forward (F
  • Page 31 – Disconnect electrical connections “N” and; silicon pipe; Remove screw “P” and remove the fan collar clamp “Q”; Disconnect the electrical connections “K” and silicone; Remove screws “M” on the top of the sealed chamber; Unscrew to remove the switch from the plate.
  • Page 32 – unscrewing in clockwise direction the white screw; Remove the pipe from the pressure gauge and connect screw “C” to the; pressure outlet in order to seal off the gas.
  • Page 33 – Regulating the heating power for; Regulating the heating power for; Regulating the heating power for
  • Page 34 – Disconnect all the cables from the solenoid and; Remove the screws “V” from the bottom of the gas valve; Disconnect ignition leads “S” by pulling upward; Remove the spark generator by pulling forward from the
  • Page 35 – Disconnect the discharge pipe work from below the; Remove the cable of the pump pressure switch “W”
  • Page 39 – Separate the facia panel from the rear of the control; Remove the inspection cover on the reverse of the; Remove the fuse mounted on the reverse of the
  • Page 40 – FAULT FINDING; YES; AULT
  • Page 42 – mbar
  • Page 47 – NOTES
Loading the manual

Installation
Instructions
Type C Boilers

G.C.N: 41-116-06

41-116-07

LEAVE THESE INSTRUCTIONS
WITH THE END-USER

Country of destination: GB

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - TABLE OF CONTENTS

2 TABLE OF CONTENTS 1. GENERAL INFORMATION 1.1 G ENERAL I NSTRUCTIONS 1.2 O VERALL V IEW 2. INSTALLATION 2.1 R EFERENCE S TANDARDS 2.2 S ITING THE A PPLIANCE 2.3 O VERALL D IMENSIONS 2.4 C LEARANCES 2.5 M OUNTING THE A PPLIANCE 2.6 E LECTRICAL C ONNECTION 2.7 G AS C ONNECTION 2.8 W ATER C ONNECTIONS...

Page 3 - Check the following at least once a year:; ENERAL

This manual is an integral and essential part of the product. It should be keptwith the appliance so that it can be consulted by the user and our authorisedpersonnel. P l e a s e c a r e f u l l y r e a d t h einstructions and notices about theunit contained in this manual, asthey provide impor tant...

Page 4 - VERALL

4 4 - Visual check of the combustion process or analysis of combustion by- products (see section 4.5) and cleaning of the burner if needed. 5 - If called for by point. 3, dismantling and cleaning of the combustion chamber. 6 - If called for by point. 4, dismantling and cleaning of the burner jets.7 ...