Page 2 - TAblE Of CONTENTS; How to enter the setup menu
2 Thermostat features . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Controls & display overview . . . . . . . . . . . . . . . . . . . 4-5 TAblE Of CONTENTS AbOUT yOUR NEw THERMOSTAT OpERATION Select system mode (HEAT/COOL) . . . . . . . . . . . . . . . . 6Change temperature set point . ...
Page 3 - wARNING; AbOUT yOUR NEw THERMOSTAT; THERMOSTAT fEATURES
3 wARNING Do not use sharp instruments to press touch screen. Only use your fingertips. AbOUT yOUR NEw THERMOSTAT THERMOSTAT fEATURES • Large touch screen with adjustable backlight – constant backlight available.• Message center provides feedback and instructions.• 7 day programmability or separatel...
Page 4 - CONTROlS & DISplAy OVERVIEw – HOME SCREEN
4 CONTROlS & DISplAy OVERVIEw – HOME SCREEN NOTE: BACkLigHT iS ACTiVATED wiTH FiRST BUTTon PRESS AnD AUToMATiCALLy TURnS oFF. CURREnT DAy FAn MoDE BUTTON FAn MoDE SETTING SySTEM MoDE BUTTON SySTEM MoDE SETTING Low BATTERy inDiCAToR CURREnT TiME & DATE MAIN MENU BUTTON TEMPERATURE SETTING TEM...
Page 5 - CONTROlS & DISplAy OVERVIEw – MAIN MENU
5 CONTROlS & DISplAy OVERVIEw – MAIN MENU AbOUT yOUR NEw THERMOSTAT SET SCHEDULE BUTTON USER SySTEM SETTingS CLEAN SCREEN (LOCKOUT TOUCH SCREEN FoR 30 SEConDS) SET CURRENT TIME SET VACATion HoLD (HoLD–To TiME AnD DATE) SET CURREnT DATE DonE BUTTon (EXiT MEnU) 61000762A 8800 Tstat Owners.indd 5 3...
Page 6 - OpERATION; to save and exit, or; press; to adjust the current set point.; SElECT SySTEM MODE
6 OpERATION press [MODE] to select: EM HEAT: (only for heat pumps with auxiliary heat) Thermostat controls auxiliary heat . Heat pump will not operate in EM HEAT mode . HEAT: Thermostat controls only the heating system . Off: Heating and cooling systems are off . COOl: Thermostat controls only the c...
Page 7 - MAINTENANCE REMINDERS
7 press [MENU] to enter the main menu . press [ClEAN SCREEN] to disable the touch screen for 30 seconds for cleaning . Note: Use a soft damp cloth to clean the screen . Use water or household glass cleaner. Do not spray liquids directly on the screen . ClEAN SCREEN SElECT fAN SETTING (ON /AUTO / CIR...
Page 8 - Batteries are not required for proper operation. The; bATTERy REplACEMENT; The reset button should only be used by the installer.
8 OpERATION Batteries are not required for proper operation. The thermostat is a 24VAC powered device with a battery back-up for the clock .The thermostat has a memory backup that saves the thermostat’s settings in case of a power interruption . The system settings will be retained but the clock wil...
Page 9 - HUMIDISTAT fUNCTIONS; Humidistat mode is selected in the user setup menu .; HUMIDISTAT CONTROl SCREEN
9 CURRENT TIME & DATE MAIN MENU BUTTON HUMiDiFiER ADJUSTMEnT nETwoRk oVERRiDE (iF EnABLED) oUTDooR TEMPERATURE HUMIDISTAT fUNCTIONS RooM RELATiVE HUMiDiTy The Model 8800 has the option of being configured as a humidistat that can control a humidifier and dehumidifier . Note: Humidistat mode is s...
Page 10 - HOw TO ENTER THE SETUp MENU TO CHANGE HUMIDISTAT MODE; to enter the main menu .; or
10 HUMIDISTAT fUNCTIONS HOw TO ENTER THE SETUp MENU TO CHANGE HUMIDISTAT MODE press [MENU] to enter the main menu . press [SETUp] to enter the setup menu . press or to adjust the setting. (Selected option flashes .)Press [DONE] to save and exit, or [CANCEl] to exit without saving . The thermostat wi...
Page 11 - NETwORK fEATURES; NETwORK OVERRIDE; or humidistat mode. when enabled, this feature can be used by; pressing; thermostat with the master PIN 7777 .; STATUS INDICATORS
11 NETwORK fEATURES NETwORK OVERRIDE The network override feature is only available to be enabled when the thermostat is set to non-programmable mode or humidistat mode. when enabled, this feature can be used by pressing [HOlD] . SECURITy A four digit security Pin can be enabled to restrict access t...
Page 12 - pROGRAMMING
12 pROGRAMMING press [Next] , then or to set the minute . press [DONE] to save and exit, or [CANCEl] to exit without saving . The thermostat will save and exit if nothing is pressed within 20 seconds . press [MENU] to enter the main menu . press [SET DATE] to enter date menu . SET DATE press [MENU] ...
Page 13 - UNDERSTANDING pROGRAM SCHEDUlES
13 UNDERSTANDING pROGRAM SCHEDUlES pROGRAMMING The daily schedule is split into four events: wAKE: temperature you would prefer to wake up to . lEAVE: temperature when you are away from the house . RETURN: temperature you would prefer to return home to . SlEEp: temperature you would prefer while sle...
Page 14 - AUTO; pROGRESSIVE RECOVERy; temperature is 70° by the time you wake at 6 am .
14 UNDERSTANDING pROGRAM SCHEDUlES (CONTINUED) pROGRAMMING optionally, the thermostat can be set to a two event or commercial schedule. (See Setup Menu on page 20.) Event designator Start time Set temperature fan Heat Cool wAkE / oCCUPiED 6:00AM 70°F (21°C) 78°F (26°C) AUTO LEAVE / UnoCCUPiED 10:00P...
Page 15 - CHANGING pROGRAM SCHEDUlES
15 pROGRAMMING press [Next] , then or to set the start time of the first event . press [MENU] to enter the main menu . press [SET SCHEDUlE] to enter schedule programming . CHANGING pROGRAM SCHEDUlES press or to select the day . press [Next] , then or to set the setpoints of the first event . Note: T...
Page 16 - The thermostat will display the CoPy option.; to copy the schedule of the day just
16 pROGRAMMING press [Next] , then [fAN] to set the fan mode of the first event . CHANGING pROGRAM SCHEDUlES (CONTINUED) press [Next] to advance to the next event . Repeat above process for each remaining event . press [DONE] to save the schedule for the day . The thermostat will display the CoPy op...
Page 17 - pROGRAM SCHEDUlE HOlDS; – TEMpORARy
17 pROGRAMMING TEMpORARy pROGRAM HOlDpress or to immediately adjust the temperature when the schedule is running . This will temporarily hold the temperature setting until the next scheduled event . pROGRAM SCHEDUlE HOlDS – TEMpORARy press or to adjust the end time of the hold. if end time is not ad...
Page 18 - To cancel the Permanent Hold,; VACATION pROGRAM HOlD; once the end date and time have been surpassed, the; to adjust the; – pERMANENT; – VACATION
18 pROGRAMMING pERMANENT pROGRAM HOlDpress [HOlD] to permanently hold the temperature at its current setting while the schedule is running . This will override the temperature settings for all events . with the thermostat in Permanent Hold, the temperature setting and fan mode can be adjusted and wi...
Page 19 - to set the fan mode .
19 pROGRAMMING VACATION pROGRAM HOlD (continued)press [Next] , then [fAN] to set the fan mode . press [Next] , then or to set end date . press [Next] , then or to set end time . press [DONE] to save and exit, or [CANCEl] to exit without saving . The thermostat will save and exit if nothing is presse...
Page 20 - SETUp MENU; HOw TO ENTER THE SETUp MENU TO CHANGE SETTINGS; to adjust the setting. (Selected option
20 SETUp MENU HOw TO ENTER THE SETUp MENU TO CHANGE SETTINGS press [MENU] to enter the main menu . press [SETUp] to enter the setup menu . press or to adjust the setting. (Selected option flashes .)Press [DONE] to save and exit, or [CANCEl] to exit without saving . The thermostat will discard change...
Page 21 - USER SySTEM SETTINGS TAblE; bold
21 USER SySTEM SETTINGS TAblE SETUp MENU The following table is the list of the settings and their details. Default settings are shown in bold . System setting Description factory default setting (bold) and setting range HUMiDiSTAT MoDE (only available if controller type is set to humidistat) HUMiDi...
Page 22 - System setting
22 USER SySTEM SETTINGS TAblE (CONTINUED) SETUp MENU System setting Description factory default setting (bold) and setting range LoCkoUT TyPE Level of lockout (only available if Security is enabled) Off: No lockout PARTIAL lockout FULL lockout MoDE LoCkoUT System mode lockout setting (only available...
Page 23 - THERMOSTAT fIVE yEAR lIMITED wARRANTy; wARRANTy REGISTRATION
23 Please…Take a few minutes to visit us on-line at www .aprilaire .com to register your Aprilaire product . if you do not have on-line access, please mail a postcard with your name, address, phone number, product purchased and date of purchase to: Research Products Corporation, P.o. BoX 1467, Madis...