Apex 16 series - Manual

Apex 16 series

Apex 16 series – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
Page: / 41

Table of Contents:

  • Page 3 – Flashing Error Message
  • Page 5 – Installation; Plumbing; always clean any tape or debris from the port threads.; Mounting; the mounting holes are shown on pages 33-35.; Application; solid-state differential pressure transducer.
  • Page 7 – RS-232 Digital Output Signal; range. Ground for this signal is common on Pin 8.; Optional 0-10 Vdc Output Signal
  • Page 9 – communications and signals)
  • Page 10 – M Series Mass Flow Meter Operation; Main Mode; parameters are displayed in the main mode as shown in Figure 6.; Tare; conditions than to give it a false zero under line pressure.
  • Page 11 – Flashing Error Message:
  • Page 12 – Select Menu Mode; If your; Gas Select Mode; display. The display will appear as shown in Figure 8 below.
  • Page 13 – Communication Select Mode; Select Main; Figure 9. Communication Select Display; Unit ID; below). This identifier allows the user; Baud
  • Page 14 – Manufacturer Data; date of manufacture.; Main; Figure 10. Manufacturer Data Displays
  • Page 15 – V Series Volumetric Flow Meter Operation; selected is shown directly under the flow units.; Figure 11. Main Mode Display, V Series Flow Meter; initial tare, give the unit a minute or so to warm up and re-zero it.
  • Page 16 – Flashing Error Message:; RS-232 Output and Input; Configuring HyperTerminal®:; all Microsoft Windows operating systems).
  • Page 17 – Changing From Streaming to Polling Mode:; able to poll the unit.
  • Page 20 – Sending a Simple Script File to HyperTerminal®; Set the cap lock on so that you are typing in capital letters.; Text; Browse and select the text “script” file you created.
  • Page 21 – Operating Principle; in a viscosity that is somewhat different than pure methane.
  • Page 24 – Refer to the calibration sheet to confirm the reference point.
  • Page 25 – Gas Viscosities, Densities and Compressibilities at 25
  • Page 26 – Gas Viscosities, Densities and Compressibilities at 0
  • Page 27 – Volumetric Flow Meters Under Pressure; This is
  • Page 28 – TROUBLESHOOTING; Display does not come on or is weak.
  • Page 29 – Maintenance and Recalibration; Apex Vacuum; Warranty
  • Page 30 – Specification; Technical Data for Micro Flow Mass & Volumetric Flow Meters; Mechanical Specifications
  • Page 31 – Technical Data for Low Flow Mass & Volumetric Flow Meters
  • Page 33 – Technical Data for High Flow Mass & Volumetric Flow Meters
  • Page 37 – Option: Totalizing Mode; over it reads “Total”.; Counter; maximum count is reached. The following options may be specified:
  • Page 38 – Option: 9 Volt Battery Pack; The Battery; Remove the 9V battery, pulling the top of the battery out first.
  • Page 39 – Battery Pack Installation/Removal; Battery Pack Installation and Removal:; into the socket until they are screwed into place.
  • Page 40 – Accessories; Pin Male Mini-DIN connector cable, single ended, 25 foot length
  • Page 41 – Calibration Certificate
Loading the manual

16 Series Mass and Volumetric Flow Meters

Precision Gas Flow Meter

Operating Manual

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 3 - Flashing Error Message

Table of Contents Page Installation 5 Plumbing 5 Mounting 5 Application 5 Power and Signal Connections 6 RS-232 Digital Output Signal 7 Standard Voltage (0-5 Vdc) Output Signal 7 Optional 0-10 Vdc Output Signal 7 Optional Current (4-20 mA) Output Signal 7 Optional 2nd Analog Output Signal 7 M Series...

Page 5 - Installation; Plumbing; always clean any tape or debris from the port threads.; Mounting; the mounting holes are shown on pages 33-35.; Application; solid-state differential pressure transducer.

5 Thank you for purchasing an Apex Gas Flow Meter. Please take the time to find and read the information contained in this manual. This will help to ensure that you get the best possible service from your instrument. This manual covers the following Apex instruments: M Series 16 Bit Mass Gas Flow Me...

Page 7 - RS-232 Digital Output Signal; range. Ground for this signal is common on Pin 8.; Optional 0-10 Vdc Output Signal

7 RS-232 Digital Output Signal If you will be using the RS-232 output signal, it is necessary to connect the RS-232 Output Signal (Pin 5), the RS-232 Input Signal (Pin 3), and Ground (Pin 8) to your computer serial port as shown in Figure 2. Adapter cables are available from the manufacturer or they...

Other Apex Models