Symmetra

LX

Start-Up Guide

Extended Run Cabinets

For use with Symmetra LX UPS models:

990-1873-001 04/2005

®

200V, 4–8 kVA

208/240V, 4–8 kVA

220/230/240V, 4–8 kVA

200V, 4–16 kVA

208/240V, 4–16 kVA

220/230/240V, 4–16 kVA

READ FIRST

Important Safety and Installation Instructions

This guide is applicable for the Symmetra LX tower and rack-mount
extended run cabinet models. These units provide extended run time for the
Symmetra LX tower or rack-mount UPS models.

See and retain the product documentation shipped with your system for
other important installation, operation, and maintenance instructions.

Illustrations are representative. The Symmetra LX configuration, including
components and optional APC equipment, may be different from the models
shown in this guide.

Entire contents copyright 2005 by American Power Conversion Corporation.
All rights reserved. Reproduction in whole or in part without permission is
prohibited.

APC, the APC logo, InfraStruXure, PowerChute, Smart-UPS and Symmetra
are registered trademarks of American Power Conversion Corporation. All
other trademarks are the property of their respective owners.

9-Battery
Rack-mount
Extended Run

9-Battery
Tower
Extended Run

3-Battery
Rack-mount
Extended Run

Overview

1. Read Safety and General Information Instructions

2. Refer to the UPS Documentation

If installing the Symmetra LX and the Extended Run Cabinet(s),
install according to the instructions in the

Symmetra LX Start-Up

Guide

shipped with the UPS.

3. Install the Extended Run Cabinet(s)

Perform the physical installation for the extended run cabinet(s).
See the included

Symmetra LX Physical Installation Guide

.

4. Follow the proceeding Start-Up Instructions

See these instructions once the physical installation for the
Extended Run Cabinet(s) is complete. This section contains
information on how to connect, test, and start the unit.

Electrical

Hazard

Read, understand and follow ALL safety
instructions contained in the

Symmetra LX Safety

Instructions and General Information Guide

.

Failure to follow safety instructions and warnings
could result in equipment damage, serious injury,
or death.

Start-Up Instructions

1. Connect the first Extended Run Cabinet

1.1 Remove the screw and battery connector cover

from the

back of the UPS.

1.2 Connect the power cable

of the first extended run cabinet

to the UPS battery connector

.

1.3 Set the dial

of the extended run cabinet to ‘2’.

1.4 Connect the communications cable

from the extended run

communications connector on the UPS

to the connector on

the extended run cabinet

.

Note

The illustrations shown in this section are applicable for the
tower and rack-mount extended run cabinets.

Note

If connecting to a UPS with integrated extended run, set the
dial of the first extended run cabinet to ‘3’ instead of ‘2’.