Thank you for selecting APC SurgeArrest! It has been designed
to provide the highest value of protection against spikes and
EMI/RFI noise on electrical lines.

Save these instructions for future reference!

SAFETY PRECAUTIONS

Do not install this device during a lightning storm!
The SurgeArrest is intended for a cool (0-40 °C) and dry

indoor environment with relative humidity of 0-95% non-
condensing. Do not install the SurgeArrest near heaters or
in a hot environment. Do not install the SurgeArrest in an
excessively moist or potentially wet environment, for example:
near bathtub, sinks, pools etc.

The SurgeArrest is intended to supply electric power to

computers, per ipher al, and elec tronic equipment. The
SurgeArrest is rated for 100 VAC, 50/60 Hz, and 15 Amps
maximum.

For best protection against spikes induced by lightning

storms, it is hightly recommended that the SurgeArrest surge
suppressor be grounded to earth.

Figure 1

Product Features

Please refer to Figure 1 for the following information and
instructions.

À.

The

Power Cord

is designed for a three wire system (two

wires carry power and the third is connected to earth). A
two to three wire Adapter Plug is provided for two wire re-
ceptacles.

Á

. Each SurgeArrest has a built-in ON/OFF

Power Switch

to

allow the user to activate electricity to connected equipment
such as computers, printers, terminals etc.

Â

. The

POWER ON

indicator is activated when the Power

Switch is ON and the unit is receiving electricity.

SurgeArrest

Ã

. The

Protection Working

indicator is activated as long

as the thermal fuse is intact. If this indicator is extinguished,
the product disconnects from the utility line. In this case,
return this unit to APC for repair or replacement.

Ä

. Seven

Outlets

are provided for your convenience.

Å

.

Telephone Protector/ Network Port Protector

(optional)

Model Pro7T-J hasa built-in one line (two wire) telephone
protector. A six foot telephone extension cord is provided.
Model Net7N-J has a built-in network protector. Network
Po r t Pr o t e c t o r ( f o r 1 0 B a s e T, 1 0 0 B a s e T, 1 0 0 B a s e T X ,
100BaseT4, 100VG-AnyLAN, & Token Ring interface cards
& HUBs).

Note:

Never connect an ISDN line to a SurgeArrest•.

Æ

. Each SurgeArrest is equipped with a 15 Amp

circuit

breaker

to protect against electrical power overload. Button

will pop up in the event of an overload. If this happens, un-
plug at least one piece of equipment, and reset button.

Ç

. A 3 prong to 2 prong

Plug Adaptor

is provided for your

convenience. See figure 3.

Figure 2

Installation Instructions

1.

Turn OFF Power Switch

Á

. The switch lever marked with

the “O” should be down.

2.

Connect the Power Cord

À

into a 100VAC receptacle. It

is highly recommended that a grounded receptacle be
used. If your receptacle is ungrounded (accepts only
plugs with two blades), attach the 3 to 2 Plug Adapter
that is supplied with the unit. The Adapter Plug has a
green wire that is used to connect to earth ground where
permitted or accessible. Please note that ungrounded
surge protectors do not provide effective surge protec-
tion between line to ground. Check local electrical laws
governing grounding practices. See Figure 3 below.

Figure 3

3.

Connect power cords of electrical equipment to be pro-

tected into the Outlets on the SurgeArrest.

4.

For model Pro7T-J, protect your telephone, fax machine,

or modem by connecting the supplied telephone exten-
sion cord into the telephone jack on the wall and con-
necting the other end into the jack marked “IN” on the

SurgeArrest. Connect your telephone equipment cord
on the jack marked “OUT” on the SurgeArrest.

5.

For model Net7N-J, protect your local area network card

by connecting the LAN cable from the Concentrator
HUB to the “IN” jack on the SurgeArrest. Connect one
end of the supplied cable to the network card jack and
c o nne c t t h e o t h e r en d to the “O U T ” j a c k o n t h e
SurgeArrest.

6.

Turn ON the SurgeArrest power switch.

7.

Turn ON connected equipment.

Note: Installation example is shown in Figure 4.

Figure 4

Mounting the SurgeArrest on a wall

The SurgeArrest has two mounting holes located on the bot-
tom of the unit. These holes were designed to hook on to
screw heads or nail heads. The spacing between the center of
the screw holes is 11.43 cm. For best results, when fastening
screws or nails into a wall, leave about 3.5 mm spacing be-
tween the wall and the bottom flange of the screw or nail.

Specifications

Unless otherwise stated, ratings are based on ambient tem-
perature of 20°C.
Operating Temperature Range: 0°C to 40°C
Operating Voltage: 100 VAC, 50/60 Hz
Operating Relative Humidity: 0 - 95% non-condensing
Safety Approval:

Dentori T-mark

For more a detailed specification, contact APC.

Table 1: AC Surge Performance Ratings

Customer Service/Technical Support

APC Japan

BR Gotanda 7th Floor
2-30-4 Nishi-gotanda
Shinagawa-ku, Tokyo 141
Japan
Phone: 03-5434-2021
Fax: 03-5434-2022
Free dial: 0120-80-60-90 (within Japan only)

American Power Conversion

132 Fairgrounds Road
West Kingston, Rhode Island 02892
USA

Internet Address: http://www.apcc.com

Parameter/Model

Professional Network

EMI/RFI Noise
Rejection (100kHz

25-60 dB

40-90 dB

to 10MHz)
Cat. A Normal Mode
Let Through Voltage

<1.4%

<0.6%

% of 6kV pulse
Total Energy Capacity

420J

680J

Peak Surge Current
(with 8x20µs pulse)

13kA

17.5kA

Normal Mode
Peak Surge Current
(with 8x20µs pulse)

11kA

22kA

Common Mode

Table 2: Telephone Protector Ratings

Parameter/Model

Professional Network

Operating Voltage

220VDC

--

Peak Surge Current
(with 8x20µs pulse)

150A

--

All Modes
Number of Lines

1

--

Protected
Connector Type

RJ45

--

Series Resistance

6−12Ω

--

Table 3: Network Protector Ratings

Parameter/Model

Professional Network

Operating Voltage

--

8VDC

EIA/TIA 568

--

Category

Performance

5

Peak Surge Current
(with 8x20µs pulse)

--

500A

Differential Modes
Peak Surge Current
(with 8x20µs pulse)

--

150A

Common Mode
Connector Type

--

RJ45

Limited Product Warranty

American Power Conversion offers a limited two year war-
ranty on SurgeArrest surge suppressors.
APC warrants its products to be free from defects in materi-
als and workmanship under normal use and service for two
years for the original purchaser. Its obligation under this
warranty is limited to repairing or replacing, at its sole op-
tion, any such defective products. To obtain service under
warranty you must obtain a Returned Material Authoriza-
tion (RMA) number from APC or an APC service center with
transportation charges prepaid and must be accompanied
by a brief description of the problem and proof of date of
purchase. This warranty applies only to the original pur-
chaser.

Part Number: 990-0167 Rev. 1 12/97